Cost-Effective Electrochemical Sensor Based on Carbon Nanotube Modified-Pencil Electrode for the Simultaneous Determination of Hydroquinone and Catechol

被引:58
作者
Ahammad, A. J. Saleh [1 ]
Akter, Tania [1 ]
Al Mamun, Abdullah [1 ]
Islam, Tamanna [1 ]
Hasan, Md. Mahedi [1 ]
Mamun, M. A. [1 ]
Faraezi, S. [1 ]
Monira, F. Z. [1 ]
Saha, Joyanta K. [1 ]
机构
[1] Jagannath Univ, Dept Chem, Dhaka 1100, Bangladesh
关键词
SENSITIVE SIMULTANEOUS DETERMINATION; REDUCED GRAPHENE OXIDE; DIHYDROXYBENZENE ISOMERS; RESORCINOL; DOPAMINE;
D O I
10.1149/2.1341809jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, the cost of working electrode was reduced greatly by replacing glassy carbon electrode (GCE) with 2B pencil. The pencil lead was modified with carbon nanotubes (CNTs) for simultaneous and quantitative detection of hydroquinone (HQ) and catechol (CT). The surface morphology of CNT-modified pencil electrode (PE-CNT) was studied by scanning electron microscopy (SEM) whereas electron transfer properties were evaluated through electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). This electrode evinced an enhanced redox reversibility and superior electrocatalytic performance concerning HQ and CT. Consecutive concentration variation studies exhibited linearity in oxidation peak responses up to 300 mu M for each of the analytes with a detection limit (S/N = 3) as low as 1.5 and 0.7 mu M for HQ and CT, respectively. We proposed a possible mechanism for their sensitive detection. The developed sensor was successfully examined for real sample analysis with tap water and it exhibited a stable and reliable recovery data with high reproducibility. The cost of the 2B pencil is 1000 times lower than that of GCE. Thus, the 2B pencil can be a good alternative to GCE in electrochemical sensor fabrication due to its economic advantage. (C) 2018 The Electrochemical Society.
引用
收藏
页码:B390 / B397
页数:8
相关论文
共 40 条
  • [31] Simultaneous determination of catechol and hydroquinone based on poly (diallyldimethylammonium chloride) functionalized graphene-modified glassy carbon electrode
    Wang, Letao
    Zhang, Yan
    Du, Yongling
    Lu, Daban
    Zhang, Yuzhen
    Wang, Chunming
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1323 - 1331
  • [32] Simultaneous quantitative determination of resorcinol and 1-naphthol in haircolor products by high-performance liquid chromatography
    Wang, LH
    Kuo, YP
    [J]. CHROMATOGRAPHIA, 1999, 49 (3-4) : 208 - 211
  • [33] Wang L, 2007, INT J ELECTROCHEM SC, V2, P216
  • [34] Deformation of Single-Walled Carbon Nanotubes by Interaction with Graphene: A First-Principles Study
    Wang, Xiao
    Yang, Juan
    Li, Ruoming
    Jiang, Hong
    Li, Yan
    [J]. JOURNAL OF COMPUTATIONAL CHEMISTRY, 2015, 36 (10) : 717 - 722
  • [35] Gold nanoparticle-graphene nanohybrid bridged 3-amino-5-mercapto-1,2,4-triazole-functionalized multiwall carbon nanotubes for the simultaneous determination of hydroquinone, catechol, resorcinol and nitrite
    Yang, Chunli
    Chai, Yaqin
    Yuan, Ruo
    Xu, Wenju
    Chen, Shihong
    [J]. ANALYTICAL METHODS, 2013, 5 (03) : 666 - 672
  • [36] Simultaneous voltammetry determination of dihydroxybenzene isomers by poly-bromophenol Blue/Carbon nanotubes composite modified electrode
    Yang, Pinghua
    Wei, Wanzhi
    Tao, Chunyuan
    Zeng, Jinxiang
    [J]. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2007, 79 (01) : 5 - 10
  • [37] High sensitive simultaneous determination of catechol and hydroquinone at mesoporous carbon CMK-3 electrode in comparison with multi-walled carbon nanotubes and Vulcan XC-72 carbon electrodes
    Yu, Jingjing
    Du, Wei
    Zhao, Faqiong
    Zeng, Baizhao
    [J]. ELECTROCHIMICA ACTA, 2009, 54 (03) : 984 - 988
  • [38] Application of multielectrode array modified with carbon nanotubes to simultaneous amperometric determination of dihydroxybenzene isomers
    Zhang, Dongdong
    Peng, Yage
    Qi, Honglan
    Gao, Qiang
    Zhang, Chengxiao
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 136 (01) : 113 - 121
  • [39] Simultaneous determination of hydroquinone and catechol at PASA/MWNTs composite film modified glassy carbon electrode
    Zhao, Dong-Ming
    Zhang, Xiu-Hua
    Feng, Li-Jun
    Jia, Li
    Wang, Sheng-Fu
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 74 (01) : 317 - 321
  • [40] A sensitive chemiluminescence method for determination of hydroquinone and catechol
    Zhao, Lijun
    Lv, Baoqiang
    Yuan, Hongyan
    Zhou, Zaide
    Xiao, Dan
    [J]. SENSORS, 2007, 7 (04) : 578 - 588