Analysis and design of notch filter-based PLLs for grid-connected applications

被引:41
作者
Khazraj, Hesam [1 ]
da Silva, F. Faria [1 ]
Bak, Claus Leth [1 ]
Golestan, Saeed [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Frequency estimation; Notch filter; Phase detection; Phase-locked loop; Synchronous reference frame; Synchronization; Three-phase systems; PHASE-LOCKED LOOP; SYNCHRONIZATION; IMPROVEMENT; INVERTERS; TRACKING; SYSTEM;
D O I
10.1016/j.epsr.2017.02.009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using multiple notch filters (NFs) inside the control loop of a standard PLL is a basic strategy to improve its filtering capability. Often, adaptive NFs (ANFs) are employed for this purpose as they can block the disturbance components even under off-nominal grid frequencies. This advantage is at the cost of a rather considerable increase in the PLL implementation complexity and computational effort, particularly when ANFs have their own frequency estimation mechanism. The non-adaptive NFs (NNFs), contrary to ANFs, are easy to implement. They, however, have received a little attention in PLL applications. Therefore, their performance characteristics are rather unclear. To gain insight about the advantages and disadvantages of NNF-based PLLs (NNF-PLLs), analysis and design of these PLLs is conducted in this paper. This procedure includes: (1) selecting the appropriate number of NNFs inside the PLL control loop, (2) approximating dynamics of cascaded NNFs with a simple first-order low-pass filter, which simplifies the tuning procedure, (3) applying the symmetrical optimum method for selecting the control parameters of the NNF-PLL, and (4) performing extensive experimental results. The obtained results indicate that NNFs can sufficiently mitigate disturbances caused by the presence of harmonics in the PLL input while maintaining a fast dynamic response for the PLL. To be more exact, the NNF-PLL can provide a settling time around 2 cycle of the nominal frequency during phase and frequency jumps while having a peak-to-peak phase error less than 0.2 degrees under a heavily distorted grid condition (THD = 15%). It, however, may not be able to effectively reject the double-frequency disturbance component caused by the grid voltage unbalance. To deal with this problem, a hybrid combination of adaptive/nonadaptive NFs is suggested in this paper. The experimental results show that the resultant PLL, which is called the HNF-PLL, completely removes the grid voltage unbalance, effectively suppresses harmonics, and offers a fast dynamic response (a settling time around 1.5 cycle of the nominal frequency). The ease of implementation is kept in the HNF-PLL as only one of the NFs is adaptive and this NF does not require a separate frequency estimation mechanism. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 69
页数:8
相关论文
共 50 条
  • [31] Synchronization Technique of Grid-Connected Power Converters Based on a Limit Cycle Oscillator
    Oviedo, Erick
    Vazquez, Nimrod
    Femat, Ricardo
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (01) : 709 - 717
  • [32] Grid-Connected Shunt Active Photovoltaic Filter
    Alali, Mohamad Alaa Eddin
    Sabiri, Zakaria
    Shtessel, Yuri B.
    Barbot, Jean-Pierre
    2020 IEEE 29TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2020, : 120 - 125
  • [33] Modeling and Resonant Characteristics Analysis of Multiple Paralleled Grid-connected Inverters with LCL Filter
    Hu Wei
    Sun Jianjun
    Ma Qian
    Yin Chenxu
    Liu Fei
    Zha Xiaoming
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 3371 - 3377
  • [34] Structure evolving and comparative analysis of grid-connected converter output filter
    Zhou, XiaoJie
    Huang, YouRui
    ELECTRICAL ENGINEERING, 2023, 105 (03) : 1849 - 1865
  • [35] dq-Frame Cascaded Delayed Signal Cancellation-Based PLL: Analysis, Design, and Comparison With Moving Average Filter-Based PLL
    Golestan, Saeed
    Ramezani, Malek
    Guerrero, Josep M.
    Monfared, Mohammad
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (03) : 1618 - 1632
  • [36] State Observer for Sensorless Control of a Grid-Connected Converter Equipped With an LCL Filter: Direct Discrete-Time Design
    Kukkola, Jarno
    Hinkkanen, Marko
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 5511 - 5518
  • [37] Robust Control Scheme for Three-Phase Grid-Connected Inverters With LCL-Filter Under Unbalanced and Distorted Grid Conditions
    Lai, Ngoc-Bao
    Kim, Kyeong-Hwa
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (02) : 506 - 515
  • [38] Optimal passive LCL filter design for grid-connected converters in weak grids
    Abbas, Hayder Hassan
    Shafiee, Qobad
    Bevrani, Hassan
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 235
  • [39] An Adaptive Quadrature Signal Generation-Based Single-Phase Phase-Locked Loop for Grid-Connected Applications
    Golestan, Saeed
    Guerrero, Josep M.
    Abusorrah, Abdullah
    Al-Hindawi, Mohammed M.
    Al-Turki, Yusuf
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (04) : 2848 - 2854
  • [40] Switching-Cycle-Based Startup for Grid-Connected Inverters
    He, Yuchen
    Li, Yuan
    Zhou, Bokang
    Peng, Fang Zheng
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN INDUSTRIAL ELECTRONICS, 2024, 5 (03): : 950 - 961