摘要
Using multiple notch filters (NFs) inside the control loop of a standard PLL is a basic strategy to improve its filtering capability. Often, adaptive NFs (ANFs) are employed for this purpose as they can block the disturbance components even under off-nominal grid frequencies. This advantage is at the cost of a rather considerable increase in the PLL implementation complexity and computational effort, particularly when ANFs have their own frequency estimation mechanism. The non-adaptive NFs (NNFs), contrary to ANFs, are easy to implement. They, however, have received a little attention in PLL applications. Therefore, their performance characteristics are rather unclear. To gain insight about the advantages and disadvantages of NNF-based PLLs (NNF-PLLs), analysis and design of these PLLs is conducted in this paper. This procedure includes: (1) selecting the appropriate number of NNFs inside the PLL control loop, (2) approximating dynamics of cascaded NNFs with a simple first-order low-pass filter, which simplifies the tuning procedure, (3) applying the symmetrical optimum method for selecting the control parameters of the NNF-PLL, and (4) performing extensive experimental results. The obtained results indicate that NNFs can sufficiently mitigate disturbances caused by the presence of harmonics in the PLL input while maintaining a fast dynamic response for the PLL. To be more exact, the NNF-PLL can provide a settling time around 2 cycle of the nominal frequency during phase and frequency jumps while having a peak-to-peak phase error less than 0.2 degrees under a heavily distorted grid condition (THD = 15%). It, however, may not be able to effectively reject the double-frequency disturbance component caused by the grid voltage unbalance. To deal with this problem, a hybrid combination of adaptive/nonadaptive NFs is suggested in this paper. The experimental results show that the resultant PLL, which is called the HNF-PLL, completely removes the grid voltage unbalance, effectively suppresses harmonics, and offers a fast dynamic response (a settling time around 1.5 cycle of the nominal frequency). The ease of implementation is kept in the HNF-PLL as only one of the NFs is adaptive and this NF does not require a separate frequency estimation mechanism. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 69
页数:8
相关论文
共 50 条
  • [21] An accurate and robust adaptive notch filter-based phase-locked loop
    Jinbo Li
    Qin Wang
    Lan Xiao
    Zehao Liu
    Qunfang Wu
    Journal of Power Electronics, 2020, 20 : 1514 - 1525
  • [22] Design and implementation of LCL-filter-based grid-connected inverters without damping
    Yao, Z. (nhyzl@163.com), 2013, Science Press (39): : 1232 - 1237
  • [23] Analysis of Inverter Output Current Ripple and Design of Inverter-Side Output Filter Inductor for Grid-Connected Applications
    Mondal, Bishal
    Karuppaswamy, B. Arun
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2025, 61 (01) : 686 - 702
  • [24] A New Control Scheme for LCL-type Grid-connected Inverter With a Notch Filter
    Zhao, Qiangsong
    Liang, Fen
    Li, Weifeng
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 4073 - 4077
  • [25] Frequency Locked Loop for Grid-Connected VSI Synchronization and Power Analysis
    Cardenas, Alben
    Guzman, Cristina
    Agbossou, Kodjo
    2012 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2012, : 1386 - 1392
  • [26] Analysis and Comparison of Notch Filter and Capacitor Voltage Feedforward Active Damping Techniques for LCL Grid-Connected Converters
    Rodriguez-Diaz, Enrique
    Freijedo, Francisco D.
    Vasquez, Juan C.
    Guerrero, Josep M.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (04) : 3958 - 3972
  • [27] A novel synchronization scheme for grid-connected converters by using adaptive linear optimal filter based PLL (ALOF-PLL)
    Han, Yang
    Xu, Lin
    Khan, Muhammad Mansoor
    Yao, Gang
    Zhou, Li-Dan
    Chen, Chen
    SIMULATION MODELLING PRACTICE AND THEORY, 2009, 17 (07) : 1299 - 1345
  • [28] Design of Dual-Notch-Filter-Based Controllers for Enhancing the Dynamic Response of Universal Single-Phase Grid-Connected Power Converters
    Borafker, Sahar
    Strajnikov, Pavel
    Kuperman, Alon
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [29] An Improved Current Control Scheme for Grid-Connected DG Unit Based Distribution System Harmonic Compensation
    He, Jinwei
    Li, Yun Wei
    Wang, Xiongfei
    Blaabjerg, Frede
    2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013), 2013, : 986 - 991
  • [30] Synchronization Technique of Grid-Connected Power Converters Based on a Limit Cycle Oscillator
    Oviedo, Erick
    Vazquez, Nimrod
    Femat, Ricardo
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (01) : 709 - 717