Analysis and design of notch filter-based PLLs for grid-connected applications

被引:41
|
作者
Khazraj, Hesam [1 ]
da Silva, F. Faria [1 ]
Bak, Claus Leth [1 ]
Golestan, Saeed [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Frequency estimation; Notch filter; Phase detection; Phase-locked loop; Synchronous reference frame; Synchronization; Three-phase systems; PHASE-LOCKED LOOP; SYNCHRONIZATION; IMPROVEMENT; INVERTERS; TRACKING; SYSTEM;
D O I
10.1016/j.epsr.2017.02.009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using multiple notch filters (NFs) inside the control loop of a standard PLL is a basic strategy to improve its filtering capability. Often, adaptive NFs (ANFs) are employed for this purpose as they can block the disturbance components even under off-nominal grid frequencies. This advantage is at the cost of a rather considerable increase in the PLL implementation complexity and computational effort, particularly when ANFs have their own frequency estimation mechanism. The non-adaptive NFs (NNFs), contrary to ANFs, are easy to implement. They, however, have received a little attention in PLL applications. Therefore, their performance characteristics are rather unclear. To gain insight about the advantages and disadvantages of NNF-based PLLs (NNF-PLLs), analysis and design of these PLLs is conducted in this paper. This procedure includes: (1) selecting the appropriate number of NNFs inside the PLL control loop, (2) approximating dynamics of cascaded NNFs with a simple first-order low-pass filter, which simplifies the tuning procedure, (3) applying the symmetrical optimum method for selecting the control parameters of the NNF-PLL, and (4) performing extensive experimental results. The obtained results indicate that NNFs can sufficiently mitigate disturbances caused by the presence of harmonics in the PLL input while maintaining a fast dynamic response for the PLL. To be more exact, the NNF-PLL can provide a settling time around 2 cycle of the nominal frequency during phase and frequency jumps while having a peak-to-peak phase error less than 0.2 degrees under a heavily distorted grid condition (THD = 15%). It, however, may not be able to effectively reject the double-frequency disturbance component caused by the grid voltage unbalance. To deal with this problem, a hybrid combination of adaptive/nonadaptive NFs is suggested in this paper. The experimental results show that the resultant PLL, which is called the HNF-PLL, completely removes the grid voltage unbalance, effectively suppresses harmonics, and offers a fast dynamic response (a settling time around 1.5 cycle of the nominal frequency). The ease of implementation is kept in the HNF-PLL as only one of the NFs is adaptive and this NF does not require a separate frequency estimation mechanism. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 69
页数:8
相关论文
共 50 条
  • [1] A Simple Approach to Enhance the Performance of Complex-Coefficient Filter-Based PLL in Grid-Connected Applications
    Ramezani, Malek
    Golestan, Saeed
    Li, Shuhui
    Guerrero, Josep M.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (06) : 5081 - 5085
  • [2] Steady-State Linear Kalman Filter-Based PLLs for Power Applications: A Second Look
    Golestan, Saeed
    Guerrero, Josep M.
    Vasquez, Juan. C.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (12) : 9795 - 9800
  • [3] A phase-locked loop using ESO-based loop filter for grid-connected converter: performance analysis
    Guo, Baoling
    Bacha, Seddik
    Alamir, Mazen
    Pouget, Julien
    CONTROL THEORY AND TECHNOLOGY, 2021, 19 (01) : 49 - 63
  • [4] Grid-Connected Phase-Locked Loop Technology Based on a Cascade Second-Order IIR Filter
    Ke, Shanwen
    Li, Yuren
    ENERGIES, 2023, 16 (09)
  • [5] A Novel Grid Synchronization PLL Method Based on Adaptive Low-Pass Notch Filter for Grid-Connected PCS
    Lee, Kyoung-Jun
    Lee, Jong-Pil
    Shin, Dongsul
    Yoo, Dong-Wook
    Kim, Hee-Je
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (01) : 292 - 301
  • [6] Digital Notch Filter Design for Grid Side Current Control of LCL-Filtered Grid-Connected Converter
    Boi, Mauro
    Bossi, Giuseppe
    Damiano, Alfonso
    2024 27TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, SPEEDAM 2024, 2024, : 332 - 338
  • [7] Stability Enhancement for Parallel Grid-Connected Inverters by Improved Notch Filter
    Yang, Ling
    Chen, Yandong
    Luo, An
    Huai, Kunshan
    IEEE ACCESS, 2019, 7 : 65667 - 65678
  • [8] An LCL-LC Filter for Grid-Connected Converter: Topology, Parameter, and Analysis
    Li, Fei
    Zhang, Xing
    Zhu, Hong
    Li, Haoyuan
    Yu, Changzhou
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) : 5067 - 5077
  • [9] Improvement of the power quality of single-phase grid-connected inverter by filter-based control scheme
    Alqatamin, Moath
    McIntyre, Michael L.
    IET POWER ELECTRONICS, 2020, 13 (08) : 1667 - 1674
  • [10] A Filter-Based Topology and Modulation Strategy With Leakage Current Mitigation for Grid-Connected CHB Photovoltaic Inverters
    Bahrami-Fard, Milad
    Moeini, Narges
    Shahabadini, Masoud
    Iman-Eini, Hossein
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (09) : 11164 - 11175