Corrosion behaviour of steel in concrete in the presence of stray current

被引:190
作者
Bertolini, Luca [1 ]
Carsana, Maddalena [1 ]
Pedeferri, Pietro [1 ]
机构
[1] Politecn Milan, Dipartimento Chim, I-20131 Milan, Italy
关键词
steel reinforced concrete; galvanostatic; passivity; stray current;
D O I
10.1016/j.corsci.2006.05.048
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Effects of stray current on the corrosion behaviour of steel in concrete have been studied, with regards to both corrosion initiation and propagation. Results showed that DC current can induce corrosion initiation on the reinforcement in the anodic zone only after it has circulated for a certain time, which depends on the anodic current density, the presence of chloride in the concrete and interruptions in the current. AC current proved to be much less dangerous than DC, although it can influence the corrosion rate of steel in chloride-contaminated concrete and stimulate macrocouples. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1056 / 1068
页数:13
相关论文
共 9 条
  • [1] BERTOLINI L, 1996, IND ITALIANA CEMENTO, V709, P268
  • [2] Bertolini L., 1993, Progress in the Understanding and Prevention of Corrosion, P658
  • [3] Bertolini L, 2004, Corrosion of Steel in Concrete: Prevention, Diagnosis, Repair
  • [4] BERTOLINI L, 1996, METALL ITAL, V88, P345
  • [5] BERTOLINI L, 2001, INT C EUR 01 EUR FED
  • [6] HAMLIN AW, 1986, MATER PERFORMANCE, V25, P55
  • [7] Heim G, 1993, 3R INT, V32, P246
  • [8] EFFECT OF ALTERNATING-CURRENT ON CORROSION OF LOW-ALLOY AND CARBON-STEELS
    JONES, DA
    [J]. CORROSION, 1978, 34 (12) : 428 - 433
  • [9] Shreir L L., 1994, Corrosion