Experimental Study of Corona Discharge Generated in a Modified Wire-Plate Electrode Configuration for Electrostatic Process Applications

被引:15
作者
Bendaoud, Abdelber [1 ]
Tilmatine, Amar [1 ]
Medles, Karim [1 ]
Younes, Mohamed [1 ]
Blejan, Octavian [2 ]
Dascalescu, Lucian [3 ]
机构
[1] Univ Djillali Liabes Sidi Bel Abbes, IRECOM Lab, Sidi Bel Abbes 22000, Algeria
[2] Renault Technol Roumanie, Voluntari 077190, Romania
[3] Univ Poitiers, ENSMA, IUT Angouleme,Electrohydrodynam Grp,CNRS, Elect Dispersed Media Res Unit,P Inst,UPR 3346, F-16021 Angouleme, France
关键词
Corona discharge; electrostatic precipitator; rotary spark gap; SPACE-CHARGE; PARTICLES; FIELD;
D O I
10.1109/TIA.2010.2041092
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Parallel wire-plate electrode arrangements are widely used to generate corona discharges in various electrostatic processes. This paper analyzes the characteristic features of a slight modification of such an electrode configuration. In all the experiments, a stainless steel wire of diameter 0.18 or 0.57 mm was used as the corona electrode, energized from a reversible dc high-voltage supply. The modified two-level grounded electrode consisted of three metallic plate segments, which are parallel to the wire and located at 20, 15 (or 10), and 20 mm from it, respectively. In a first set of experiments, the current-voltage characteristics of this electrode arrangement were obtained for both polarities of the high-voltage supply and compared to those of a standard wire-plate electrode system. In a second set of experiments, two of the plate segments were made of several aluminum strips insulated from each other and successively connected to a microammeter, in order to characterize the distribution of the corona current at the surface of the modified grounded electrode. The third set of experiments described in this paper was performed with the corona electrode energized from a rotary spark gap connected at the output of the dc high-voltage supply. Finally, the possibility of applying this modified electrode configuration for the precipitation of dust contained in flue gases is briefly discussed.
引用
收藏
页码:666 / 671
页数:6
相关论文
共 28 条
  • [1] ELECTRIC-FIELD AROUND PARALLEL DC AND MULTIPHASE AC TRANSMISSION-LINES
    ABDELSALAM, M
    ELMOHANDES, MT
    ELKISHKY, H
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1990, 25 (06): : 1145 - 1152
  • [2] A FINITE-ELEMENT ANALYSIS OF BIPOLAR IONIZED FIELD
    ABDELSALAM, M
    ALHAMOUZ, Z
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (03) : 477 - 483
  • [3] Particle charging by unipolar ionic bombardment in an AC electric field
    Adamiak, K
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) : 421 - 426
  • [4] Finite-element solution of monopolar corona on bundle conductors
    Al-Hamouz, ZM
    Abdel-Salam, M
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (02) : 380 - 386
  • [5] ALHAMOUZ AZ, 1995, IEEE T IND APPL, V34, P57
  • [6] Corona charging of granular layers of insulating particles at the surface of a grounded electrode
    Bendaoud, A
    Dascalescu, L
    Blajan, M
    Samuila, A
    Stochita, A
    Notingher, PV
    [J]. JOURNAL OF ELECTROSTATICS, 2005, 63 (6-10) : 643 - 647
  • [7] Characterization of dual corona-electrostatic electrodes for electrostatic processes applications
    Bendaoud, Abdelber
    Tilmatine, Amar
    Medles, Karim
    Rahli, Mostefa
    Huzau, Mihai
    Dascalescu, Lupian
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (03) : 692 - 698
  • [8] Current-density approximation for efficient computation of the electrostatic field in wire-plate precipitators
    Beux, F
    Iollo, A
    Salvetti, MV
    Soldati, A
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (03) : 858 - 865
  • [9] Blejan O, 2007, IEEE IND APPLIC SOC, P1111
  • [10] Bolognesi A., 2008, INT C URB DRAIN, P1, DOI DOI 10.1109/ICDL.2008.4622490