Sensitivity analysis of structural parameters of a low-temperature heat pump sludge drying system

被引:12
作者
Cai, Jingyong [1 ]
Zhou, Haihua [1 ]
Zhang, Tao [1 ]
Shi, Zhengrong [1 ]
Meng, Qingliang [2 ]
机构
[1] Shanghai Univ Elect Power, Coll Energy & Mech Engn, Shanghai 201306, Peoples R China
[2] Beijing Inst Space Mech & Elect, Beijing 100094, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat pump; Sludge drying; Steady-state models; Sensitivity analysis; AIR-SIDE PERFORMANCE; MASS-TRANSFER; SIMULATION ANALYSIS; SEWAGE-SLUDGE; TUBE ROWS; DEHUMIDIFICATION; EXCHANGERS; NUMBER; MODEL; SIZE;
D O I
10.1016/j.applthermaleng.2022.118172
中图分类号
O414.1 [热力学];
学科分类号
摘要
Optimizations of the heat exchanger of the heat pump drying system were usually carried out individually, linkage effect of the whole system in practical operating was usually not considered. In addition, for a heat pump sludge drying system, optimizations mainly concentrated on the operation parameters, few theoretical analyses focused on the effect of structural parameters to the system performance. In the present study, based on the laws of energy conservation and mass conservation, a steady-state model for the heat pump sludge drying system, which interconnects the refrigerant circulation and the moist air circulation, was established. Three variables which are coefficient of performance (COP), dehumidification rate (DR), and specific moisture extraction rate (SMER) are simultaneously introduced to evaluate the system's operating and drying performances. Effects of the number of horizontal tube rows, the number of longitudinal tube rows, and the fin spacing to the above three variables are analyzed. The results show that the COP decreases with increasing the number of horizontal tube rows while increases with increasing the number of longitudinal tube rows and fin spacing. The DR increases with increasing the number of horizontal tube rows and fin spacing and decreases with increasing the number of longitudinal tube rows. The SMER has a similar variation trend to that of the DR due to their directly proportional relationship. Finally, based on the sensitivity analysis, the heat pump sludge drying system achieves better operating and drying performances when the fin spacing is 2.85 mm, the numbers of horizontal tube rows of the evaporator and condenser are 18 and 14, and the numbers of longitudinal tube rows are respectively 12 and 9.
引用
收藏
页数:16
相关论文
共 44 条
[1]   Performance characteristics of a dual-evaporator heat pump system for effective dehumidifying and heating of a cabin in electric vehicles [J].
Ahn, Jae Hwan ;
Kang, Hoon ;
Lee, Ho Seong ;
Kim, Yongchan .
APPLIED ENERGY, 2015, 146 :29-37
[2]   Modeling and Simulation of Heat and Mass Transfer During Convective Drying of Wastewater Sludge with Introduction of Shrinkage Phenomena [J].
Bennamoun, Lyes ;
Fraikin, Laurent ;
Leonard, Angelique .
DRYING TECHNOLOGY, 2014, 32 (01) :13-22
[3]   Determination of the mass transfer coefficient during hot-air-drying of celery root [J].
Bialobrzewski, Ireneusz .
JOURNAL OF FOOD ENGINEERING, 2007, 78 (04) :1388-1396
[4]   Comparison of the working domains of some compression heat pumps and a compression-absorption heat pump [J].
Brunin, O ;
Feidt, M ;
Hivet, B .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1997, 20 (05) :308-318
[5]   A novel PV/T-air dual source heat pump water heater system: Dynamic simulation and performance characterization [J].
Cai, Jingyong ;
Ji, Jie ;
Wang, Yunyun ;
Zhou, Fan ;
Yu, Bendong .
ENERGY CONVERSION AND MANAGEMENT, 2017, 148 :635-645
[6]   Thermal characteristics of heat pump dryer for ginger drying [J].
Chapchaimoh, Khanuengnit ;
Poomsa-ad, Nattapol ;
Wiset, Lamul ;
Morris, John .
APPLIED THERMAL ENGINEERING, 2016, 95 :491-498
[7]   Sludge dewatering and drying [J].
Chen, GH ;
Yue, PL ;
Mujumdar, AS .
DRYING TECHNOLOGY, 2002, 20 (4-5) :883-916
[8]   A new drying kinetic model for sewage sludge drying in presence of CaO and NaClO [J].
Danish, Mohammed ;
Hu Jing ;
Zhou Pin ;
Lou Ziyang ;
Qian Pansheng .
APPLIED THERMAL ENGINEERING, 2016, 106 :141-152
[9]   Simulation analysis on dynamic performance of a combined solar/air dual source heat pump water heater [J].
Deng, Weishi ;
Yu, Jianlin .
ENERGY CONVERSION AND MANAGEMENT, 2016, 120 :378-387
[10]   Thermal characteristics of a novel enclosed cascade-like heat pump dryer used in a tunnel type drying system [J].
Duan, Quancheng ;
Wang, Dechang ;
Li, Xuerui ;
Li, Yanhui ;
Zhang, Shaohong .
APPLIED THERMAL ENGINEERING, 2019, 155 :206-216