The value of the left atrial appendage orifice perimeter of 3D model based on 3D TEE data in the choice of device size of LAmbre™ occluder

被引:8
作者
Jia, Dan [1 ]
Zhou, Qing [1 ]
Song, Hong-ning [1 ]
Zhang, Lan [1 ]
Chen, Jin-ling [1 ]
Liu, Yu [2 ]
Kong, Bin [2 ]
He, Fa-zhi [3 ]
Wang, Yi-jia [1 ]
Yang, Yuan-ting [1 ]
机构
[1] Wuhan Univ, Renmin Hosp, Dept Ultrasound Imaging, Wuhan, Hubei, Peoples R China
[2] Wuhan Univ, Renmin Hosp, Dept Cardiol, Wuhan, Hubei, Peoples R China
[3] Wuhan Univ, Comp Sci & Technol Sch, Wuhan, Hubei, Peoples R China
关键词
Left atrial appendage closure; Size; Orifice; Three-dimensional transesophageal echocardiography; Computed tomography; Three-dimensional model; CLOSURE DEVICE; OCCLUSION;
D O I
10.1007/s10554-019-01627-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Preoperative optimal selection of the occluder size is crucial in percutaneous left atrial appendage (LAA) occlusion, and the maximal width of the LAA orifice is the main reference index, however it can not fully meet the practical operation requirements. We retrospectively analyzed three-dimensional (3D) transesophageal echocardiography (TEE) and computed tomography (CT) imaging dataset of the 41 patients who underwent LAA occlusion with LAmbre (TM) system. The LAA orifice parameters were overall evaluated to determine their role in device size selection. Eight LAA 3D models of the four cases who had been replaced their device during the procedure based on TEE and CT were printed out to verify the optimal parameter decision strategy. There was a significant concordance of the results between 3D TEE and CT in the LAA orifice evaluation. The correlations between the perimeter and maximal width measurements by 3D TEE and the closure disk of the device were stronger than that between the area measurements and the closure disk (r = 0.93, 0.95, 0.86, respectively and p < 0.001 all), and the result was similar to that by CT (r = 0.92, 0.93, 0.84, respectively and p < 0.001 all). The ratios of the maximal width to the minimal width of the four cases were all > 1.4, however the rest 37 cases were all <= 1.4. Based on the comprehensive assessment of the LAA orifice perimeter and maximal width of the 3D printed models, the experiments were all succeed just for one try. The LAA orifice perimeter of 3D printed model based on 3D TEE may help in choosing the optimal device size of LAmbre (TM), especially for the LAA with flater ostial shape.
引用
收藏
页码:1841 / 1851
页数:11
相关论文
共 23 条
  • [1] The Left Atrial Appendage: Anatomy, Function, and Noninvasive Evaluation
    Beigel, Roy
    Wunderlich, Nina C.
    Ho, Siew Yen
    Arsanjani, Reza
    Siegel, Robert J.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2014, 7 (12) : 1251 - 1265
  • [2] Prospective randomized evaluation of the watchman left atrial appendage closure device in patients with atrial fibrillation versus long-term warfarin therapy The PREVAIL trial
    Belgaid, Djouhar Roufeida
    Khan, Zara
    Zaidi, Mariam
    Hobbs, Adrian
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 219 : 177 - 179
  • [3] Left atrial appendage occlusion simulation based on three-dimensional printing: new insights into outcome and technique
    Ciobotaru, Vlad
    Combes, Nicolas
    Martin, Claire A.
    Marijon, Eloi
    Maupas, Eric
    Bortone, Augustin
    Bruguiere, Eric
    Thambo, Jean-Benoit
    Teiger, Emmanuel
    Pujadas-Berthault, Penelope
    Ternacle, Julien
    Iriart, Xavier
    [J]. EUROINTERVENTION, 2018, 14 (02) : 176 - 184
  • [4] Cruz-González I, 2018, REV ESP CARDIOL, V71, P755, DOI [10.1016/j.rec.2017.04.015, 10.1016/j.recesp.2017.02.023]
  • [5] Percutaneous left atrial appendage occlusion for stroke prevention in atrial fibrillation: an update
    De Backer, O.
    Arnous, S.
    Ihlemann, N.
    Vejlstrup, N.
    Jorgensen, E.
    Pehrson, S.
    Krieger, T. D. W.
    Meier, P.
    Sondergaard, L.
    Franzen, O. W.
    [J]. OPEN HEART, 2014, 1 (01):
  • [6] Goitein O, 2017, EUROINTERVENTION, V13, P1076, DOI 10.4244/EIJ-D-16-00921
  • [7] Cardiac CT Angiography (CCTA) predicts left atrial appendage occluder device size and procedure outcome
    Goitein, Orly
    Fink, Noam
    Hay, Ilan
    Di Segni, Elio
    Guetta, Victor
    Goitein, David
    Brodov, Yafim
    Konen, Eli
    Glikson, Michael
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (05) : 739 - 747
  • [8] Cardiac 3D printing for better understanding of congenital heart disease
    Hadeed, Khaled
    Acar, Philippe
    Dulac, Yves
    Cuttone, Fabio
    Alacoque, Xavier
    Karsenty, Clement
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2018, 111 (01) : 1 - 4
  • [9] 3D printing for sizing left atrial appendage closure device: head-to-head comparison with computed tomography and transoesophageal echocardiography
    Hell, Michaela M.
    Achenbach, Stephan
    Yoo, In Seong
    Franke, Joerg
    Blachutzik, Florian
    Roether, Jens
    Graf, Verena
    Raaz-Schrauder, Dorette
    Marwan, Mohamed
    Schlundt, Christian
    [J]. EUROINTERVENTION, 2017, 13 (10) : 1234 - 1241
  • [10] Role of cardiac imaging and three-dimensional printing in percutaneous appendage closure
    Iriart, Xavier
    Ciobotaru, Vlad
    Martin, Claire
    Cochet, Hubert
    Jalal, Zakaria
    Thambo, Jean-Benoit
    Quessard, Astrid
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2018, 111 (6-7) : 411 - 420