Short-term assessment of radial artery grafts with multidetector computed tomography

被引:6
作者
Qiao, En [1 ]
Wang, Yuetang [1 ]
Yu, Jun [1 ]
Wang, Xu [1 ]
Luo, Xinjin [1 ]
Wang, Wei [1 ]
机构
[1] Peking Union Med Coll, Chinese Acad Med Sci, Fuwai Hosp, Struct Heart Dis Ctr,Natl Ctr Cardiovasc Dis, 167 Beilishi Rd, Beijing, Peoples R China
关键词
Coronary artery bypass grafting; Radial artery; Coronary artery disease; Multidetector computed tomography; CORONARY; FLOW; PATENCY; OUTCOMES; HARVEST;
D O I
10.1186/s13019-021-01465-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The clinical use of the radial artery (RA) in coronary artery bypass grafting (CABG) is still limited worldwide, although it has been recommended by several guidelines. Multidetector computed tomography (MDCT) is widely used to evaluate graft patency, as invasive coronary angiography could cause potentially serious risks including bleeding, dissection and stroke. This study aims to report the short-term results of the RA in CABG with MDCT. Methods: The study population consists of 41 consecutive patients undergoing elective CABG with the RA graft between 2017 to 2018, with MDCT performed to evaluate graft patency during follow-up, and target vessels for the RA were non-left anterior descending coronary arteries with > 70% stenosis. Results: A total of 150 grafts were assessed by MDCT during follow-up (mean, 8.9 +/- 5.1 months). MDCT could clearly show the structure and patency of grafts, even for complex coronary artery revascularization. Graft patency of the left internal mammary artery was 92.9% (39/42), with the RA patency of 84.4% (38/45) and the patency of the saphenous vein graft of 81.1% (30/37). And the RA anastomosed to the left coronary artery system might have better patency than the RA anastomosed to the right coronary artery system (25/29, 86.2% vs 13/16, 81.3%, p = 0.686). Conclusions: The short-term patency rate of RA grafts is good, and the RA might be associated with better patency when anastomosed to the left but not the right coronary artery. MDCT could provide excellent visualization of grafts in CABG.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Diagnostic Accuracy of Dual-Source 64-Slice Multidetector Computed Tomography in Evaluation of Coronary Artery Bypass Grafts
    Sahiner, Levent
    Canpolat, Ugur
    Yorgun, Hikmet
    Hazirolan, Tuncay
    Karcaaltincaba, Musturay
    Sunman, Hamza
    Kaya, Ergun Baris
    Aytemir, Kudret
    Oto, Ali
    JOURNAL OF INVESTIGATIVE MEDICINE, 2012, 60 (08) : 1180 - 1185
  • [32] Long-term internal thoracic artery bypass graft patency and geometry assessed by multidetector computed tomography
    Zacho, Mette
    Damgaard, Sune
    Lilleoer, Nikolaj Thomas
    Kelbaek, Henning
    Steinbruchel, Daniel
    Nielsen, Michael Bachmann
    Kofoed, Klaus Fuglsang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06) : 1577 - 1583
  • [33] Coronary Artery Disease in an Asymptomatic Population Undergoing a Multidetector Computed Tomography (MDCT) Coronary Angiography
    Zaid, Ghassan
    Yehudai, Dana
    Rosenschein, Uri
    Zeina, Abdel-Rauf
    OPEN CARDIOVASCULAR MEDICINE JOURNAL, 2010, 4 : 7 - 13
  • [34] Long-Term Radial Artery Grafts with Previous Midterm Proven Patency
    Silva, Roberto Rocha e
    Goncharov, Maxim
    de Freitas, Fabiane Leticia
    Mejia, Omar Asdrubal Vilca
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2023, 38 (02) : 244 - 247
  • [35] There an Indication for Computed Tomography and Magnetic Resonance Imaging in the Evaluation of Coronary Artery Bypass Grafts?
    Dikkers, R.
    van der Zaag-Loonen, H. J.
    Willems, T. P.
    Post, W. J.
    Oudkerk, M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (03) : 317 - 327
  • [36] Multidetector computed tomography (MDCT) for preoperative airway assessment in children with mucopolysaccharidoses
    Ingelmo, P. M.
    Parini, R.
    Grimaldi, M.
    Mauri, F.
    Romagnoli, M.
    Tagliabue, G.
    Somaini, M.
    Sahillioglu, E.
    Frawley, G.
    MINERVA ANESTESIOLOGICA, 2011, 77 (08) : 774 - 780
  • [37] Multidetector computed tomography assessment of venous invasion in hepatic alveolar echinococcosis
    Zhang, Tieliang
    Zhang, Yuan
    Wang, Jian
    Hou, Juan
    Liu, Wenya
    ABDOMINAL RADIOLOGY, 2023, 48 (01) : 297 - 305
  • [38] Investigation of proper hepatic artery and gastroduodenal artery variations by multidetector computed tomography angiography method
    Ekingen, Arzu
    Tuncer, Mehmet Cudi
    Ertugrul, Ozgur
    ACTA CHIRURGICA BELGICA, 2020, 120 (02) : 102 - 115
  • [39] Assessment of mastoid emissary foramen morphology: a multidetector computed tomography study
    Erturk, Ahmet Faruk
    Unsal, Gurkan
    Goksel, Sevde
    Celebi, Elif
    Tunc, Hamit
    Marrapodi, Maria Maddalena
    Cicciu, Marco
    Minervini, Giuseppe
    ORAL RADIOLOGY, 2025, : 372 - 377
  • [40] Multidetector computed tomography assessment of venous invasion in hepatic alveolar echinococcosis
    Tieliang Zhang
    Yuan Zhang
    Jian Wang
    Juan Hou
    Wenya Liu
    Abdominal Radiology, 2023, 48 : 297 - 305