Short-term assessment of radial artery grafts with multidetector computed tomography

被引:6
|
作者
Qiao, En [1 ]
Wang, Yuetang [1 ]
Yu, Jun [1 ]
Wang, Xu [1 ]
Luo, Xinjin [1 ]
Wang, Wei [1 ]
机构
[1] Peking Union Med Coll, Chinese Acad Med Sci, Fuwai Hosp, Struct Heart Dis Ctr,Natl Ctr Cardiovasc Dis, 167 Beilishi Rd, Beijing, Peoples R China
关键词
Coronary artery bypass grafting; Radial artery; Coronary artery disease; Multidetector computed tomography; CORONARY; FLOW; PATENCY; OUTCOMES; HARVEST;
D O I
10.1186/s13019-021-01465-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The clinical use of the radial artery (RA) in coronary artery bypass grafting (CABG) is still limited worldwide, although it has been recommended by several guidelines. Multidetector computed tomography (MDCT) is widely used to evaluate graft patency, as invasive coronary angiography could cause potentially serious risks including bleeding, dissection and stroke. This study aims to report the short-term results of the RA in CABG with MDCT. Methods: The study population consists of 41 consecutive patients undergoing elective CABG with the RA graft between 2017 to 2018, with MDCT performed to evaluate graft patency during follow-up, and target vessels for the RA were non-left anterior descending coronary arteries with > 70% stenosis. Results: A total of 150 grafts were assessed by MDCT during follow-up (mean, 8.9 +/- 5.1 months). MDCT could clearly show the structure and patency of grafts, even for complex coronary artery revascularization. Graft patency of the left internal mammary artery was 92.9% (39/42), with the RA patency of 84.4% (38/45) and the patency of the saphenous vein graft of 81.1% (30/37). And the RA anastomosed to the left coronary artery system might have better patency than the RA anastomosed to the right coronary artery system (25/29, 86.2% vs 13/16, 81.3%, p = 0.686). Conclusions: The short-term patency rate of RA grafts is good, and the RA might be associated with better patency when anastomosed to the left but not the right coronary artery. MDCT could provide excellent visualization of grafts in CABG.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Multidetector computed tomography pulmonary angiogram in the assessment of myocardial infarction
    Moore, William
    Fields, Jack
    Mieczkowski, Brian
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (05) : 800 - 803
  • [12] Left main coronary artery atresia diagnosed by multidetector computed tomography
    Saito, Takahiko
    Motohashi, Masatoshi
    Matsushima, Shouji
    Saito, Naotaka
    Kubota, Takehiro
    Tasai, Kimitaka
    Asajima, Hiroshi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 135 (01) : E27 - E29
  • [13] Multidetector computed tomography imaging of coronary artery anomalies
    Turkvatan, Aysel
    Guray, Yesim
    Altinsoy, Dilek
    CARDIOLOGY IN THE YOUNG, 2013, 23 (05) : 661 - 674
  • [14] Diagnostic Accuracy of 64 row Multidetector Computed Tomography for Coronary Artery Disease Assessment
    Hamon, M.
    JOURNAL DE RADIOLOGIE, 2009, 90 (7-8): : 779 - 785
  • [15] Three-Dimensional Images of Extra-Routine Grafts in CABG by Multidetector Computed Tomography
    Nabuchi, Akihiro
    Kurata, Atsushi
    Okuyama, Hiroshi
    Kondo, Takeshi
    Muto, Yasuji
    Endo, Yuki
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 14 (05) : 333 - 335
  • [16] A 16-slice multidetector computed tomography protocol for evaluation of the gastroepiploic artery grafts in patients after coronary artery bypass surgery
    Dorgelo, J
    Willems, TP
    van Ooijen, PMA
    Panday, GFV
    Boonstra, PW
    Zijlstra, F
    Oudkerk, M
    EUROPEAN RADIOLOGY, 2005, 15 (09) : 1994 - 1999
  • [17] A 16-slice multidetector computed tomography protocol for evaluation of the gastroepiploic artery grafts in patients after coronary artery bypass surgery
    J. Dorgelo
    T. P. Willems
    P. M. A. van Ooijen
    G. F. V. Panday
    P. W. Boonstra
    F. Zijlstra
    M. Oudkerk
    European Radiology, 2005, 15 : 1994 - 1999
  • [18] Coronary artery aneurysms as seen on multidetector computed Tomography angiography
    Roy, Sion K.
    Kadakia, Jigar
    Shittu, Adekunle
    Budoff, Matthew J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (07) : 1127 - 1132
  • [19] Use of multidetector computed tomography for evaluating coronary artery disease in patients undergoing dialysis
    Park, Moo Yong
    Choi, Soo Jeong
    Kim, Jin Kuk
    Hwang, Seung Duk
    Suh, Jon
    Seo, Hye Sun
    Kim, Dong Hun
    NEPHROLOGY, 2011, 16 (03) : 285 - 289
  • [20] Study of coronary artery bypass using the PAS-Port device: Assessment by multidetector computed tomography
    Fujii T.
    Watanabe Y.
    Shiono N.
    Ozawa T.
    Hamada S.
    Masuhara H.
    Teramoto C.
    Hara M.
    Koyama N.
    General Thoracic and Cardiovascular Surgery, 2009, 57 (2) : 79 - 86