Vertically Ordered Silica Mesochannel Modified Bipolar Electrode for Electrochemiluminescence Imaging Analysis

被引:36
作者
Guo, Weiliang [1 ]
Lin, Xingyu [1 ]
Yan, Fei [1 ]
Su, Bin [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
关键词
antibiofouling; bipolar electrodes; electrochemiluminescence imaging; ordered silica mesochannels; sensors; SOLID-STATE ELECTROCHEMILUMINESCENCE; MICROCHIP CAPILLARY-ELECTROPHORESIS; INDIUM TIN OXIDE; ELECTROGENERATED CHEMILUMINESCENCE; THIN-FILMS; ECL REACTION; RU(BPY)(3)(2+); PLATFORM; SYSTEM; ELECTROCHEMISTRY;
D O I
10.1002/celc.201500329
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This paper describes a miniaturized bipolar electrode (BPE) sensor that is constructed with an indium tin oxide (ITO) microband and a slice of poly(dimethylsioxane) (PDMS). The ITO microband modified by vertically ordered silica mesochannels (SMCs) functions as the BPE. Owing to the uniform pore size of approximate to 2-3nm in diameter and negatively charged surface, the SMCs can significantly accelerate the mass transport of positively charged species via strong electrostatic interactions. Thus, an increase of more than two orders of magnitude in sensitivity for tri-n-propylamine (TPrA) analysis was achieved for the electrochemluminescence (ECL) of tris(2,2-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) at a relatively low concentration (10m). Moreover, the SMC film with ultrasmall channels can effectively serve as an antifouling layer of the underlying ITO electrode to prevent the access of undesired large molecules, allowing the electrochemical detection in real complex media, such as atropine and l-proline in human blood serum.
引用
收藏
页码:480 / 486
页数:7
相关论文
共 65 条
[1]   ELECTROGENERATED CHEMI-LUMINESCENCE .40. A CHEMI-LUMINESCENT POLYMER BASED ON THE TRIS(4-VINYL-4'-METHYL-2,2'-BIPYRIDYL)RUTHENIUM(II) SYSTEM [J].
ABRUNA, HD ;
BARD, AJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1982, 104 (09) :2641-2642
[2]   Bipolar Electrode Focusing: Faradaic Ion Concentration Polarization [J].
Anand, Robbyn K. ;
Sheridan, Eoin ;
Knust, Kyle N. ;
Crooks, Richard M. .
ANALYTICAL CHEMISTRY, 2011, 83 (06) :2351-2358
[3]   Electrosynthesis of polythiophene nanowires via mesoporous silica thin film templates [J].
Angelica del Valle, Ma. ;
Gacitua, Manuel ;
Diaz, Fernando R. ;
Armijo, Francisco ;
del Rio, Rodrigo .
ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (11) :2117-2120
[4]   A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device [J].
Arora, A ;
Eijkel, JCT ;
Morf, WE ;
Manz, A .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3282-3288
[5]   Determination of atropine using Mn-doped ZnS quantum dots as novel luminescent sensitizers [J].
Azizi, Seyed Naser ;
Chaichi, Mohammad Javad ;
Shakeri, Parmis ;
Bekhradnia, Ahmadreza .
JOURNAL OF LUMINESCENCE, 2013, 144 :34-40
[6]   Approaches Toward Allowing Electroanalytical Devices to be Used in Biological Fluids [J].
Barfidokht, Abbas ;
Gooding, J. Justin .
ELECTROANALYSIS, 2014, 26 (06) :1182-1196
[7]   Surface chemistry to minimize fouling from blood-based fluids [J].
Blaszykowski, Christophe ;
Sheikh, Sonia ;
Thompson, Michael .
CHEMICAL SOCIETY REVIEWS, 2012, 41 (17) :5599-5612
[8]   Lighting Up Redox Propulsion with Luminol Electrogenerated Chemiluminescence [J].
Bouffier, Laurent ;
Zigah, Dodzi ;
Adam, Catherine ;
Sentic, Milica ;
Fattah, Zahra ;
Manojlovic, Dragan ;
Kuhn, Alexander ;
Sojic, Neso .
CHEMELECTROCHEM, 2014, 1 (01) :95-98
[9]   Two-channel microelectrochemical bipolar electrode sensor array [J].
Chang, Byoung-Yong ;
Chow, Kwok-Fan ;
Crooks, John A. ;
Mavre, Francois ;
Crooks, Richard M. .
ANALYST, 2012, 137 (12) :2827-2833
[10]   Wireless electrochemical DNA microarray sensor [J].
Chow, Kwok-Fan ;
Mavre, Francois ;
Crooks, Richard M. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (24) :7544-+