100A AC-DC current measurements to within ±25ppm from 3 Hz to 1kHz

被引:2
|
作者
Clarke, KK
机构
[1] Clarke-Hess Communication Research Corporation, 300 Riverside Drive, New York
关键词
Software-controlled digitizing voltmeters - Thermal convertors;
D O I
10.1049/ip-smt:20000527
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper uses a set of computer controlled commercial equipment in conjunction with a software-controlled digitising voltmeter to produce accurate 100A current measurements at +/-DC and in the frequency range from 0.1Hz to 1kHz. Overall uncertainties in the region of +/-20ppm appear possible. The paper concentrates on 100A results; however, the concepts work down to 10A and up to at least 1kA. The resultant system is nearly immune to the thermal problems and warm-up times that plague shunts and thermal convertors, particularly for currents greater than 20A. A method to separate the transfer functions of the amplifier and the transducer is proposed. Experimental verification of the method and of the system performance is provided.
引用
收藏
页码:186 / 189
页数:4
相关论文
共 15 条
  • [1] Extending ac-dc current transfer measurement to 100 A, 100 kHz
    Rydler, Karl-Erik
    Tarasso, Valter
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 28 - 29
  • [2] Extending AC-DC Current Transfer to 100 A, 100 kHz in UME
    Arifovic, Mehedin
    Kanatoglu, Naylan
    Uzun, Serdar
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [3] Extension of the NIST AC-DC difference calibration service for current to 100 kHz
    Kinard, JR
    Lipe, TE
    Childers, CB
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1997, 102 (01) : 75 - 83
  • [4] 20-A to 100-A AC-DC coaxial current shunts for 100 kHz frequency range
    Filipski, Piotr S.
    Boecker, Michael
    Garcocz, Martin
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 518 - +
  • [5] 20-A to 100-A AC-DC coaial current shunts for 100-kHz frequency range
    Filipski, Piotr S.
    Boecker, Michael
    Garcocz, Martin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (08) : 1637 - 1641
  • [6] Design Method of DC Power Supply for Superposing 20kHz/100A Peak to Peak Sinusoidal Current with Several Hundred DC Current to Analyze Battery AC Impedance
    Xu, Jin
    Kishimoto, Toshihiko
    Shimosato, Noboru
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 5338 - 5343
  • [7] Characterization of AC-DC Transfer Shunts up to 100 A at 100 kHz Using Two-Stage, Amplifier-Aided Current Transformers
    Kinard, Joseph
    Laug, Owen
    Waltrip, Bryan
    Lipe, Thomas
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 107 - 110
  • [8] Establishment of High-Voltage AC-DC Voltage Transfer Standards in 1-100-kHz Range at NMIJ
    Fujiki, Hiroyuki
    Amagai, Yasutaka
    Okawa, Kenjiro
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (06) : 1921 - 1926
  • [9] ACCURATE AC MEASUREMENTS OF THE QUANTIZED HALL RESISTANCE FROM 1-HZ TO 1,6-KHZ
    DELAHAYE, F
    METROLOGIA, 1995, 31 (05) : 367 - 373
  • [10] System conversion from DC 1, 5 kV to AC 25 kV 50 Hz
    Keseljevic, Christophe
    Courtois, Christian
    Aeberhard, Martin
    eb - Elektrische Bahnen, 2015, 113 (6-7): : 313 - 321