The effect of direct and indirect force transmission on peri-implant bone stress - a contact finite element analysis

被引:18
作者
Rand, Annike [1 ]
Stiesch, Meike [1 ]
Eisenburger, Michael [1 ]
Greuling, Andreas [1 ]
机构
[1] Hannover Med Sch, Dept Prosthet Dent & Biomed Mat Sci, Hannover, Germany
关键词
Non-linear contact analysis; peri-implant bone stress; occlusal loading area; finite element analysis; prosthodontics; OSSEOINTEGRATED IMPLANTS; DENTAL IMPLANTS; MASTICATION; OCCLUSION; ZIRCONIA; POSTS; TOOTH; LOAD;
D O I
10.1080/10255842.2017.1338691
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In almost all finite element (FE) studies in dentistry, virtual forces are applied directly to dentures. The purpose of this study was to develop a FE model with non-linear contact simulation using an antagonist as force transmitter and to compare this with a similar model that uses direct force transmission. Furthermore, five contact situations were created in order to examine their influence on the peri-implant bone stresses, which are relevant to the survival rate of implants. It was found that the peri-implant bone stresses were strongly influenced by the kind of force transmission and contact number.
引用
收藏
页码:1132 / 1139
页数:8
相关论文
共 36 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]   Effect of framework material and vertical misfit on stress distribution in implant-supported partial prosthesis under load application: 3-D finite element analysis [J].
Bacchi, Atais ;
Xediek Consani, Rafael Leonardo ;
Mesquita, Marcelo Ferraz ;
Fernandes dos Santos, Mateus Bertolini .
ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (05) :1243-1249
[3]  
Bastos FS, 2010, IOP C SER MAT SCI EN, V10, P1
[4]   Brief communication: Comparing loading scenarios in lower first molar supporting bone structure using 3D finite element analysis [J].
Benazzi, Stefano ;
Kullmer, Ottmar ;
Grosse, Ian R. ;
Weber, Gerhard W. .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2012, 147 (01) :128-134
[5]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[6]  
Byrne G., 2014, FUNDAMENTALS IMPLANT, V1A
[7]   Tooth displacement due to occlusal contacts: a three-dimensional finite element study [J].
de Oliveira, S. Gomes ;
Seraidarian, P. I. ;
Landre, J., Jr. ;
Oliveira, D. D. ;
Cavalcanti, B. N. .
JOURNAL OF ORAL REHABILITATION, 2006, 33 (12) :874-880
[8]   Three-dimensional finite element analysis of molars with thin-walled prosthetic crowns made of various materials [J].
Dejak, Beata ;
Mlotkowski, Andrzej ;
Langot, Cezary .
DENTAL MATERIALS, 2012, 28 (04) :433-441
[9]   The use of acoustic microscopy to study the mechanical properties of glass-ionomer cement [J].
Denisova, LA ;
Maev, RG ;
Poyurovskaya, IY ;
Grineva, TV ;
Denisov, AF ;
Maeva, EY ;
Bakulin, EY .
DENTAL MATERIALS, 2004, 20 (04) :358-363
[10]   Influence of abutment design on the success of immediately loaded dental implants: Experimental and numerical studies [J].
Hasan, I. ;
Roeger, B. ;
Heinemann, F. ;
Keilig, L. ;
Bourauel, C. .
MEDICAL ENGINEERING & PHYSICS, 2012, 34 (07) :817-825