Three-dimensional nonstationary electrical impedance tomography with a single electrode layer

被引:14
|
作者
Voutilainen, A. [1 ,2 ]
Lehikoinen, A. [1 ,2 ]
Vauhkonen, M. [1 ,2 ]
Kaipio, J. P. [1 ,2 ,3 ]
机构
[1] Univ Kuopio, Dept Phys, FIN-70211 Kuopio, Finland
[2] Numcore Ltd, FIN-70210 Kuopio, Finland
[3] Univ Auckland, Dept Math, Auckland, New Zealand
基金
芬兰科学院;
关键词
electrical impedance tomography; state estimation; electrode configuration; IN-PROCESS TOMOGRAPHY; CURRENT COMPUTED-TOMOGRAPHY; EXTENDED KALMAN FILTER; STATE ESTIMATION; MODELS; RECONSTRUCTION;
D O I
10.1088/0957-0233/21/3/035107
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In a tubular vessel equipping a single electrode layer, true three-dimensional electrical impedance tomography imaging is generally not considered possible. In a nonstationary setting, however, the accumulation of information over an epoch can possibly allow for 3D imaging if appropriate evolution models are available. Such an evolution model is the stochastic convection-diffusion model if the flow field is such that the main flow is along the tube. A single electrode layer sensor would obviously be much cheaper and could be installed in locations in which a multi-layer sensor possibly could not be. In this paper, we assess this possibility both computationally and experimentally. The results show that a single electrode layer system is a potential technique in nonstationary estimation.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Three-dimensional electrical impedance tomography using complete electrode model
    Vauhkonen, M
    Vauhkonen, PJ
    Kaipio, JP
    Karjalainen, PA
    COMPUTATIONAL, EXPERIMENTAL, AND NUMERICAL METHODS FOR SOLVING ILL-POSED INVERSE IMAGING PROBLEMS: MEDICAL AND NONMEDICAL APPLICATIONS, 1997, 3171 : 166 - 174
  • [2] Three-dimensional electrical impedance tomography based on the complete electrode model
    Vauhkonen, PJ
    Vauhkonen, M
    Savolainen, T
    Kaipio, JP
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (09) : 1150 - 1160
  • [3] Electrical impedance tomography for three-dimensional drug release monitoring
    Rimpilainen, Ville
    Kuosmanen, Marko
    Ketolainen, Jarkko
    Jarvinen, Kristiina
    Vauhkonen, Marko
    Heikkinen, Lasse M.
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 41 (02) : 407 - 413
  • [4] Compressed sampling for boundary measurements in three-dimensional electrical impedance tomography
    Javaherian, Ashkan
    Soleimani, Manuchehr
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (09) : 1133 - 1149
  • [5] Estimation of electrode contact impedance and conductivity of single-layer graphene using electrical impedance tomography
    Khambampati, Anil Kumar
    Sharma, Sunam Kumar
    Kim, Kyung Youn
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (08)
  • [6] RECOVERING CONDUCTIVITY AT THE BOUNDARY IN THREE-DIMENSIONAL ELECTRICAL IMPEDANCE TOMOGRAPHY
    Nakamura, Gen
    Ronkanen, Paivi
    Siltanen, Samuli
    Tanuma, Kazumi
    INVERSE PROBLEMS AND IMAGING, 2011, 5 (02) : 485 - 510
  • [7] Local detection of three-dimensional inclusions in electrical impedance tomography
    Ide, T.
    Isozaki, H.
    Nakata, S.
    Siltanen, S.
    INVERSE PROBLEMS, 2010, 26 (03)
  • [8] Electrical impedance tomography reconstruction for three-dimensional imaging of the prostate
    Borsic, A.
    Halter, R.
    Wan, Y.
    Hartov, A.
    Paulsen, K. D.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (08) : S1 - S16
  • [9] An image reconstruction algorithm for three-dimensional electrical impedance tomography
    Le Hyaric, A
    Pidcock, MK
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (02) : 230 - 235
  • [10] Design of Three-Dimensional Electrical Impedance Tomography System for Rock Samples
    Peng, Xin
    Chun, Shaoheng
    Su, Benyu
    Chen, Rujun
    Hou, Shenglan
    Xu, Chao
    Zhang, Haojie
    APPLIED SCIENCES-BASEL, 2024, 14 (04):