Simulation on the time dependence of breakdown strength in insulating polymers

被引:13
|
作者
Wu, Kai [1 ]
Cheng, Yonghong [1 ]
机构
[1] Xian Jiaotong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
关键词
D O I
10.1063/1.2715521
中图分类号
O59 [应用物理学];
学科分类号
摘要
On the basis of the percolation model for electrical breakdown in insulating polymers, a simulation approach was put forward for the process of electrical aging. The deteriorated regions formed by bond scission are expressed as the sites with lower trap barriers, and the local deterioration rate is related to both the electrical field and the size of existing deteriorated regions. Then the reduction of breakdown strength (or the percolation threshold) with the increase of deteriorated sites can be simulated. Assuming a parameter beta to reflect the effect of the size of existing deteriorated region, simulation results show two types of breakdown: percolationlike breakdown for beta <= 2 (in which the percolation threshold is reduced due to the gradual global increase of deteriorated sites) and avalanchelike breakdown for beta > 2 (in which breakdown occurs by the rapid growth of a filamentary structure). Moreover, it is indicated that the lifetime might not be in inverse proportion to the local deterioration rate in the case of percolationlike breakdown. (c) 2007 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] ON THE EXTREME CHARACTER OF THE DEPENDENCE ON TIME OF THE BREAKDOWN FORMATION ON THE MAGNETIC-FIELD STRENGTH
    KISHOV, MRG
    EHFENDIEV, AZ
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOFIZIKA, 1982, 25 (11): : 1256 - 1259
  • [22] The presence of a local minimum in the dependence of breakdown delay time on magnetic field strength
    K. M. -R. Kishov
    M. -R. G. Kishov
    Plasma Physics Reports, 2004, 30 : 714 - 715
  • [23] RELAXATION CURRENTS IN INSULATING POLYMERS AND THEIR DEPENDENCE ON THE POLYMER STRUCTURE
    HANSEL, H
    RELAXATION IN POLYMERS, 1989, 80 : 236 - 244
  • [24] EFFECT OF CONSTITUENTS OF INSULATING OILS ON THEIR GASSING PROPERTIES AND BREAKDOWN STRENGTH
    NOSSEIR, A
    LAWRENCE, R
    NATURE, 1965, 206 (4979) : 85 - &
  • [25] Influence of Nonmetallic Particles on the Breakdown Strength of Vegetable Insulating Oil
    Zhang, Jing
    Li, Jian
    Huang, Dali
    Zhang, Xiaomeng
    Liang, Suning
    Li, Xudong
    2015 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2015, : 609 - 612
  • [26] CARRIER INJECTION, SPACE CHARGE AND ELECTRICAL BREAKDOWN IN INSULATING POLYMERS.
    Ieda, M.
    IEEE transactions on electrical insulation, 1987, EI-22 (03): : 261 - 267
  • [27] CARRIER INJECTION, SPACE-CHARGE AND ELECTRICAL BREAKDOWN IN INSULATING POLYMERS
    IEDA, M
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1987, 22 (03): : 261 - 267
  • [28] DEPENDENCE OF IMPULSE BREAKDOWN STRENGTH ON CABLE LENGTH
    KANEKO, R
    SUGIYAMA, K
    ELECTRICAL ENGINEERING IN JAPAN, 1973, 93 (03) : 62 - 68
  • [29] VOLUME DEPENDENCE OF ELECTRIC STRENGTH OF POLYMERS
    MORTON, VM
    STANNETT, AW
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1968, 115 (12): : 1857 - &
  • [30] TEMPERATURE-DEPENDENCE OF STRENGTH OF POLYMERS
    SAVITSKII, AV
    MALCHEVSKII, VA
    SANFIROVA, TP
    ZOSIN, LP
    VYSOKOMOLEKULYARNYE SOEDINENIYA SERIYA A, 1974, 16 (09): : 2130 - 2135