Development of 60 MHz integrated backscatter intravascular ultrasound and tissue characterization of attenuated signal coronary plaques that cause myocardial injury after percutaneous coronary intervention

被引:5
作者
Sahashi, Yuki [1 ]
Kawasaki, Masanori [3 ]
Okubo, Munenori [3 ]
Kawamura, Itta [3 ]
Kawase, Yoshiaki [3 ]
Yoshida, Akihiro [1 ]
Tanaka, Toshiki [1 ]
Hattori, Arihiro [3 ]
Matsuo, Hitoshi [3 ]
Ozaki, Yukio [2 ]
机构
[1] Gifu Univ, Dept Cardiol, Grad Sch Med, Gifu, Japan
[2] Fujita Med Univ, Dept Cardiol, Toyoake, Aichi, Japan
[3] Gifu Heart Ctr, Dept Cardiovasc Med, 4-14-4 Yabuta Minami, Gifu 5008384, Japan
关键词
Coronary artery disease; Integrated backscatter; Intravascular ultrasound; Tissue characterization; Attenuated plaque; ARTERY CALCIFICATION; VULNERABLE PLAQUES; HISTOLOGY;
D O I
10.1007/s00380-022-02080-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the present study was to develop a 60 MHz integrated backscatter intravascular ultrasound (IB-IVUS) and to evaluate its usefulness for the detection of lipid area with backward attenuation of ultrasound signal (AT) that for the prediction of post-procedural myocardial injury (PMI) after percutaneous coronary intervention (PCI). In a pathological study, images were acquired from 221 cross-sections of 18 coronary arteries from 13 cadavers obtained at autopsy. In the clinical training study, we compared non-targeted plaques in 38 patients by a previous IB-IVUS system (38 MHz) and a new IB-IVUS system (60 MHz). In the clinical testing study, we included 70 consecutive patients who underwent PCI. Serum troponin-I was measured just before and 24 h after PCI to evaluate PMI. As the % microcalcification + % cholesterol cleft area increased, the attenuation of IB values increased (r = 0.56, p < 0.001). The slopes of regression lines of the area of each tissue component between 38 and 60 MHz IB-IVUS were excellent. The lipid pool area with AT tended to be more useful than that of the conventional lipid pool area for the prediction of PMI (p = 0.11). We developed a 60 MHz IB-IVUS imaging system for tissue characterization of coronary plaques. Cutoff value of purple color was the most reliable value for the prediction of PMI.
引用
收藏
页码:1689 / 1700
页数:12
相关论文
共 29 条
[1]   Effect of Cholesterol Crystals on Plaques and Intima in Arteries of Patients With Acute Coronary and Cerebrovascular Syndromes [J].
Abela, George S. ;
Aziz, Kusai ;
Vedre, Ameeth ;
Pathak, Dorothy R. ;
Talbott, John D. ;
DeJong, Joyce .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (07) :959-968
[2]   Diagnostic Performance of High-Resolution Intravascular Ultrasound for Abnormal Post-Stent Findings After Stent Implantation A Comparison Study Between High-Resolution Intravascular Ultrasound and Optical Coherence Tomography [J].
Ando, Hirohiko ;
Nakano, Yusuke ;
Sawada, Hiroaki ;
Ohashi, Hirofumi ;
Takashima, Hiroaki ;
Suzuki, Akihiro ;
Sakurai, Shinichiro ;
Amano, Tetsuya .
CIRCULATION JOURNAL, 2021, 85 (06) :883-+
[3]   Detailed Characterization of Vulnerable Plaque Morphology by High-Resolution Intravascular Ultrasound [J].
Ando, Hirohiko ;
Ohashi, Hirofumi ;
Nakano, Yusuke ;
Takashima, Hiroaki ;
Amano, Tetsuya .
CIRCULATION JOURNAL, 2020, 84 (09) :1606-1606
[4]   Effects of transducer position on backscattered intensity in coronary arteries [J].
Courtney, BK ;
Robertson, AL ;
Maehara, A ;
Luna, J ;
Kitamura, K ;
Morino, Y ;
Achalu, R ;
Kirti, S ;
Yock, PG ;
Fitzgerald, PJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (01) :81-91
[5]  
Ferreira RM, 2017, CARDIOVASC REVASCULA, V18, P255, DOI 10.1016/j.carrev.2017.01.008
[6]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[7]  
Hara Hisao, 2006, Acute Card Care, V8, P110, DOI 10.1080/14628840600637781
[8]  
Ito Shigenori, 2004, J Invasive Cardiol, V16, P669
[9]   Volumetric quantitative analysis of tissue characteristics of coronary plaques after statin therapy using three-dimensional integrated backscatter intravascular ultrasound [J].
Kawasaki, M ;
Sano, K ;
Okubo, M ;
Yokoyama, H ;
Ito, Y ;
Murata, I ;
Tsuchiya, K ;
Minatoguchi, S ;
Zhou, XR ;
Fujita, H ;
Fujiwara, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (12) :1946-1953
[10]   In vivo quantitative tissue characterization of human coronary arterial plaques by use of integrated backscatter intravascular ultrasound and comparison with angioscopic findings [J].
Kawasaki, M ;
Takatsu, H ;
Noda, T ;
Sano, K ;
Ito, Y ;
Hayakawa, K ;
Tsuchiya, K ;
Arai, M ;
Nishigaki, K ;
Takemura, G ;
Minatoguchi, S ;
Fujiwara, T ;
Fujiwara, H .
CIRCULATION, 2002, 105 (21) :2487-2492