Human movement analysis using stereophotogrammetry - Part 1: theoretical background

被引:455
作者
Cappozzo, A
Della Croce, U
Leardini, A
Chiari, L
机构
[1] Ist Ortoped Rizzoli, Ctr Ric Codivilla Putti, Lab Anal Movimento, I-40136 Bologna, Italy
[2] Ist Univ Sci Motorie, I-00194 Rome, Italy
[3] Univ Sassari, Dipartimento Sci Biomed, I-07100 Sassari, Italy
[4] Univ Bologna, Dipartimento Elettron Informat & Sistemist, I-40136 Bologna, Italy
关键词
stereophotogrammetry; human movement analysis; joint kinematics;
D O I
10.1016/j.gaitpost.2004.01.010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This paper sets the stage for a series of reviews dealing with the problems associated with the reconstruction and analysis of in vivo skeletal system kinematics using optoelectronic stereophotogrammetric data. Instantaneous bone position and orientation and joint kinematic variable estimations are addressed in the framework of rigid body mechanics. The conceptual background to these exercises is discussed. Focus is placed on the experimental and analytical problem of merging the information relative to movement and that relative to the morphology of the anatomical body parts of interest. The various global and local frames that may be used in this context are defined. Common anatomical and mathematical conventions that can be used to describe joint kinematics are illustrated in a comparative fashion. The authors believe that an effort to systematize the different theoretical and experimental approaches to the problems involved and related nomenclatures, as currently reported in the literature, is needed to facilitate data and knowledge sharing. and to provide renewed momentum for the advancement of human movement analysis. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 196
页数:11
相关论文
共 39 条
  • [1] Correcting for deformation in skin-based marker systems
    Alexander, EJ
    Andriacchi, TP
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (03) : 355 - 361
  • [2] [Anonymous], HUMAN GAIT
  • [3] [Anonymous], 2001, MEASUREMENT HUMAN LO
  • [4] [Anonymous], 3 DIMENSIONAL ANAL H
  • [5] Basmajian J. V., 1985, MUSCLES ALIVE THEIR
  • [6] A COMPARISON OF THE ACCURACY OF SEVERAL HIP CENTER LOCATION PREDICTION METHODS
    BELL, AL
    PEDERSEN, DR
    BRAND, RA
    [J]. JOURNAL OF BIOMECHANICS, 1990, 23 (06) : 617 - 621
  • [7] Berme N., 1990, BIOMECHANICS HUMAN M, P140
  • [8] Multiple anatomical landmark calibration for optimal bone pose estimation
    Cappello, A
    Cappozzo, A
    LaPalombara, PF
    Lucchetti, L
    Leardini, A
    [J]. HUMAN MOVEMENT SCIENCE, 1997, 16 (2-3) : 259 - 274
  • [9] CAPPELLO A, 1997, 3 DIMENSIONAL ANAL H, P147
  • [10] Surface-marker cluster design criteria for 3-D bone movement reconstruction
    Cappozzo, A
    Cappello, A
    DellaCroce, U
    Pensalfini, F