Quality of vision after AMO array multifocal intraocular lens implantation

被引:99
|
作者
Sen, HN [1 ]
Sarikkola, AU [1 ]
Uusitalo, RJ [1 ]
Laatikainen, L [1 ]
机构
[1] Univ Helsinki, Hosp Eye, Helsinki 00029, Finland
来源
关键词
D O I
10.1016/j.jcrs.2004.04.049
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate safety and efficacy of Array(R) SA40N multifocal intraocular lens (IOL) (AMO) implantation in cataract surgery. Setting: Helsinki University Eye Hospital, Helsinki, Finland. Methods: In this prospective randomized comparative trial, 80 patients scheduled for cataract surgery were selected based on preoperative counseling and randomized to have multifocal or monofocal IOL implantation. Fifty-three eyes of 35 patients received a multifocal IOL and 67 eyes of 40 patients, a monofocal IOL. The incidence of complications and visual outcome in the multifocal and monofocal IOL groups were compared. Quality of vision was measured by comparing the severity of visual symptoms (glare, halos, and cataract symptoms score), changes in functional impairment measured by a 7-item visual function test (VF-7), changes in global measures of vision (trouble and satisfaction with vision), and range of accommodation and contrast sensitivity. Results: Intraoperative and postoperative complications and adverse events were few and required no further surgical intervention. Both distance and near visual acuities were significantly better in the multifocal group than in the monofocal group; the difference was most prominent in distance corrected near acuity (P<.001). Thirty-five eyes (67.3%) in the multifocal group and 10 eyes (14.9%) in the monofocal group achieved a distance corrected near acuity of J6 (20/40) or better; 30 eyes (56.6%) and 19 eyes (28.4%), respectively, achieved a best corrected distance acuity of 20/20 or better. Glare symptoms decreased postoperatively in both groups but were slightly more common in the multifocal group. In contrast, halos were significantly more common at 1 month in the multifocal group (P<.001). Contrast sensitivity values were slightly lower with multifocal IOLs at almost all spatial frequencies, but the difference was not significant. The change in the quality of life postoperatively, measured with the VF-7, was significant and identical in both groups. Conclusions: Pseudophakic eyes with multifocal IOLs had better distance and near acuity and range of accommodation than eyes with a monofocal IOL. Slightly lower contrast sensitivity and increased perception of halos by subjects with the multifocal IOL appear to be an acceptable compromise to enhanced near and distance vision.
引用
收藏
页码:2483 / 2493
页数:11
相关论文
共 50 条
  • [1] Piggyback implantation using the AMO Array multifocal intraocular lens
    Donoso, R
    Rodríguez, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (09): : 1506 - 1510
  • [2] The influence of personality on the quality of vision after multifocal intraocular lens implantation
    Pinheiro, Rosa L. L.
    Raimundo, Miguel
    Gil, Joao Q.
    Henriques, Jorge
    Rosa, Andreia M. M.
    Quadrado, Maria Joao
    Lobo, Conceicao
    Murta, Joaquim N. N.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (01) : 154 - 160
  • [3] The AMO array foldable silicone multifocal intraocular lens
    Fine, IH
    Hoffman, RS
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 2000, 40 (03) : 245 - 252
  • [4] EFFECT OF AGE AND ASTIGMATISM ON THE AMO ARRAY MULTIFOCAL INTRAOCULAR-LENS
    JACOBI, PC
    KONEN, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (05): : 556 - 561
  • [5] Quality of vision after bilateral multifocal intraocular lens implantation in pregeriatric Hispanic population, after refractive lens exchange
    Alberto Nava, Jose
    Rubi Morales-Mancillas, Nallely
    Valdez, Jorge E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [6] A comparative study on early vision quality after implantation of refractive segmental and diffractive multifocal intraocular lens
    Lian, Huifang
    Ma, Weisong
    Wei, Qiuhong
    Yuan, Xiaoyong
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2020, 36 (07) : 1607 - 1612
  • [7] Dissatisfaction after multifocal intraocular lens implantation
    Woodward, Maria A.
    Randleman, J. Bradley
    Stulting, R. Doyle
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06): : 992 - 997
  • [8] Dissatisfaction after multifocal intraocular lens implantation
    Tarib, Imane
    Asroui, Lara
    Ferguson, Tanner
    Randleman, James
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [9] A prospective comparative study of the AMO ARRAY zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lens
    Steinert, RF
    Aker, BL
    Trentacost, DJ
    Smith, PJ
    Tarantino, N
    OPHTHALMOLOGY, 1999, 106 (07) : 1243 - 1255
  • [10] The Preliminary Clinical Observation of Array Multifocal Intraocular Lens Implantation
    Zhende Lin
    Bo Feng
    Yizhi Liu
    Bing Cheng
    Yuping Zou
    眼科学报, 2001, (01) : 57 - 60