Fabrication and drive test of pneumatic PDMS micro pump

被引:83
作者
Jeong, Ok Chan
Konishi, Satoshi
机构
[1] INJE Univ, Dept Biomed Engn, Gimhae 621749, Gyengnam, South Korea
[2] Ritsumeikan Univ, Dept Micro Syst Technol, Kusatsu, Shiga 5258577, Japan
基金
日本科学技术振兴机构;
关键词
PDMS; peristaltic micro pump; pneumatic actuation; flow rate;
D O I
10.1016/j.sna.2006.09.012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a pneumatically driven peristaltic PDMS micro pump toward harmless blood delivery system. Micro pump consists of three peristaltic-type actuators as dynamic valves and a micro channel connecting two chambers and two fluidic ports. Micro pump is fabricated through the PDMS mold process and the two-step curing process for irreversible bonding of PDMS layers. For the characterization of the pneumatic actuator, the deflection of actuator diaphragm is observed by using video camera. It is found out that the square-wave pneumatic input signal is preferable for the pneumatic action method to increase the volume stroke of the pneumatic PDMS actuators. Three types of the performance of micro pump in the frequency domain are performed while the square-wave input pneumatic pressure is applied to actuators. The maximum water suction volume speed from inlet port to micro pump is about 0.48 mu L/s at 0.3 Hz under 7 cmH(2)O of the hydraulic pressure difference between two fluidic ports. The maximum meniscus speed of the red-ink in the micro channel is about 0.83 mm/s at 5 Hz. In the case of the injection test, the injected volume is approximately estimated with the recorded video clips showing the generated dynamic valve area of the actuator chamber region. It is about 75 nL, at 1 Hz. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:849 / 856
页数:8
相关论文
共 20 条
[1]   MICROPHYSICAL INVESTIGATIONS ON MECHANICAL STRUCTURES REALIZED IN P(+) SILICON [J].
CABUZ, C ;
FUKATSU, K ;
KURABAYASHI, T ;
MINAMI, K ;
ESASHI, M .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1995, 4 (03) :109-118
[2]  
Cabuz C, 2001, PROC IEEE MICR ELECT, P519, DOI 10.1109/MEMSYS.2001.906593
[3]  
CABUZ C, 1999, TRANSDUCERS 99, P1890
[4]   THE BAND MODEL AND THE ETCHING MECHANISM OF SILICON IN AQUEOUS KOH [J].
CHEN, LC ;
CHEN, MJ ;
LIEN, CH ;
WAN, CC .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (01) :170-176
[5]   Fabrication of a peristaltic PDMS micropump [J].
Jeong, OC ;
Park, SW ;
Yang, SS ;
Pak, JJ .
SENSORS AND ACTUATORS A-PHYSICAL, 2005, 123-24 :453-458
[6]   Correlation between residual stress and boron concentration in boron-doped silicon films [J].
Jeong, OC ;
Yang, SS .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (1A) :350-357
[7]   Fabrication of a thermopneumatic microactuator with a corrugated p plus silicon diaphragm [J].
Jeong, OC ;
Yang, SS .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 80 (01) :62-67
[8]   Fabrication and test of a thermopneumatic micropump with a corrugated p plus diaphragm [J].
Jeong, OC ;
Yang, SS .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 83 (1-3) :249-255
[9]  
JEONG OC, 2005, P MICR TAS 2005 BOST, P202
[10]   All PDMS pneumatic microfinger with bidirectional motion and its application [J].
Jeong, Ok Chan ;
Konishi, Satoshi .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2006, 15 (04) :896-903