The Investigation on the Flow Distortion Effect of Header to Guarantee the Measurement Accuracy of the Ultrasonic Gas Flowmeter

被引:8
作者
Chen, Wenlin [1 ,2 ]
Wu, Jianjun [1 ]
Li, Chunhui [3 ]
机构
[1] Lanzhou Univ, Coll Civil Engn & Mech, Lanzhou 730000, Peoples R China
[2] Xinjiang Inst Measurement & Testing Technol, Urumqi 830011, Peoples R China
[3] Natl Inst Metrol, Beijing 100011, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 08期
关键词
ultrasonic gas flowmeter; flow field distortion; flow conditioner; header; flow standard device; METER; SIMULATION; VELOCITY; FIELD;
D O I
10.3390/app11083656
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application This study investigated the flow distortion effect of the header on the measurement accuracy of the ultrasonic gas flowmeter by experiments and CFD, and the physical mechanism of characteristic parameters on measurement accuracy was explored. The quantification of the flow distortion effect on the measurement accuracy of the ultrasonic gas flowmeter downstream of the header is important but an area that has been of less concern in the research. By experiments and computational fluid dynamics (CFD), the influence of flow field distortion was studied. Experimental results under three different installation conditions showed that when there was flow field distortion downstream of the header, the measurement results of the gas ultrasonic flowmeter were 1% higher than those when there was no distortion, while a flow conditioner could effectively eliminate flow field distortion. Based on the experimental tests, the flow field distribution was analyzed with CFD, which showed that the flow field distortion effect generated by the header had a significant influence on the parameter of nonconforming Profile factor, while the parameters of Symmetry and Cross-flow could be obviously eliminated by the double-cross-section designing.
引用
收藏
页数:17
相关论文
共 47 条
[1]  
American Gas Association, 1998, MEASUREMENT GAS MULT
[2]  
[Anonymous], 2011, ASME PTC18 2011
[3]  
[Anonymous], 2014, ICS 7518030
[4]  
Brown G.J., 2006, P 18 IMEKO WORLD C R
[5]  
Chen W., 2015, Ph.D. Thesis
[6]   Correction of flow metering coefficients by using multi-dimensional non-linear curve fitting [J].
Chun, Sejong ;
Yoon, Byung-Ro ;
Lee, Duck-Ki ;
Choi, Hae-Man .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (11) :3479-3489
[7]   The manufacturing of ultrasonic gas flow meters [J].
Drenthen, JG ;
de Boer, G .
FLOW MEASUREMENT AND INSTRUMENTATION, 2001, 12 (02) :89-99
[8]  
Emerson Process Management, 2010, TODAYS ULTRASONIC ME
[9]   A numerical investigation of different parameters that affect the performance of a flow conditioner [J].
Erdal, A .
FLOW MEASUREMENT AND INSTRUMENTATION, 1997, 8 (02) :93-102
[10]   Flow conditioners efficiency a comparison based on numerical approach [J].
Frattolillo, A ;
Massarotti, N .
FLOW MEASUREMENT AND INSTRUMENTATION, 2002, 13 (1-2) :1-11