ESTIMATION OF COMPUTED TOMOGRAPHY DOSE INDEX IN CONE BEAM COMPUTED TOMOGRAPHY: MOSFET MEASUREMENTS AND MONTE CARLO SIMULATIONS

被引:12
作者
Kim, Sangroh [2 ]
Yoshizumi, Terry [1 ,3 ,4 ]
Toncheva, Greta [1 ,3 ]
Yoo, Sua [4 ]
Yin, Fang-Fang [4 ]
Frush, Donald [3 ]
机构
[1] Duke Univ, Med Ctr, Div Radiat Safety, Durham, NC 27710 USA
[2] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[3] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
来源
HEALTH PHYSICS | 2010年 / 98卷 / 05期
关键词
computed tomography; medical radiation; dose assessment; Monte Carlo; FLAT-PANEL IMAGER; RADIATION-THERAPY; CT; CBCT;
D O I
10.1097/HP.0b013e3181cd3ec3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To address the lack of accurate dose estimation method in cone beam computed tomography (CBCT), we performed point dose metal oxide semiconductor field-effect transistor (MOSFET) measurements and Monte Carlo ( MC) simulations. A Varian On-Board Imager (R) (OBI) was employed to measure point doses in the polymethyl methacrylate (PMMA) CT phantoms with MOSFETs for standard and low dose modes. A MC model of the OBI x-ray tube was developed using BEAMnrc/EGSnrc MC system and validated by the half value layer, x-ray spectrum and lateral and depth dose profiles. We compared the weighted computed tomography dose index (CTDIw) between MOSFET measurements and MC simulations. The CTDIw was found to be 8.39 cGy for the head scan and 4.58 cGy for the body scan from the MOSFET measurements in standard dose mode, and 1.89 cGy for the head and 1.11 cGy for the body in low dose mode, respectively. The CTDIw from MC compared well to the MOSFET measurements within 5% differences. In conclusion, a MC model for Varian CBCT has been established and this approach may be easily extended from the CBCT geometry to multi-detector CT geometry. Health Phys. 98(5):683-691; 2010
引用
收藏
页码:683 / 691
页数:9
相关论文
共 30 条
  • [1] [Anonymous], PIRS794REVB NRCC
  • [2] *BEST MED CAN, 4TN10124804 BEST MED
  • [3] In-room CT techniques for image-guided radiation therapy
    Charlie, CM
    Paskalev, K
    [J]. MEDICAL DOSIMETRY, 2006, 31 (01) : 30 - 39
  • [4] Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy
    Ding, George X.
    Duggan, Dennis M.
    Coffey, Charles W.
    [J]. MEDICAL PHYSICS, 2008, 35 (03) : 1135 - 1144
  • [5] Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy
    Ding, George X.
    Duggan, Dennis M.
    Coffey, Charles W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (06) : 1595 - 1615
  • [6] Dixon RL, 2003, MED PHYS, V30, P1272, DOI 10.1118/1.1576952
  • [7] Herman M G, 2000, J Appl Clin Med Phys, V1, P38, DOI 10.1120/1.308249
  • [8] Clinical use of electronic portal imaging: Report of AAPM radiation therapy committee Task Group 58
    Herman, MG
    Balter, JM
    Jaffray, DA
    McGee, KP
    Munro, P
    Shalev, S
    Van Herk, M
    Wong, JW
    [J]. MEDICAL PHYSICS, 2001, 28 (05) : 712 - 737
  • [9] *I PHYS ENG MED, 1997, 78 IPEM
  • [10] *INT XRAY ABS SOC, XRAY DAT W