Strain of the anterior band of the inferior glenohumeral ligament during capsule failure

被引:45
作者
Stefko, JM
Tibone, JE
Cawley, PW
ElAttrache, NE
McMahon, PJ
机构
[1] KERLAN JOBE ORTHOPAED CLIN, INGLEWOOD, CA 90301 USA
[2] UNIV CALIF IRVINE, DEPT ORTHOPAED SURG, IRVINE, CA 92717 USA
[3] DON JOY BIOMECH & RES LAB, CARLSBAD, CA 92008 USA
关键词
D O I
10.1016/S1058-2746(97)70055-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Efficacious surgical treatment of glenohumeral instability requires a combination of anterior band origin repair and capsuloligamentous plication. The purpose of this article was to determine anterior band of the inferior glenohumeral ligament stretching at the time of glenohumeral failure. Thirteen Fresh-frozen cadaver glenohumeral joints were thawed and dissected of soft tissue except for the capsuloligamentous structures. Testing was performed with a material testing system device, simulating the anterior instability apprehension position of the shoulder with 90 degrees of shoulder abduction and the humerus externally rotated until the bicipital groove was aligned with the supraglenoid tubercle. The length of each anterior band of the inferior glenohumeral ligament was obtained, and a variable reluctance transducer was applied to the anterior band midsubstance. Tensile testing at a strain rate of 100%/sec ensued until complete capsular failure occurred. Mid-substance strain of the anterior band of the inferior glenohumeral ligament at the time of capsular failure averaged 7.23% +/- 2.25% (mean +/- SD) with a range of 3.68% to 10.68%. Load to failure was 712.9 +/- 238.2 N (range 363.6 to 1136.9 N). All of the glenohumeral capsules failed at the glenoid origin, simulating a Bankart lesion, except for one that failed at the humeral insertion. When the intact capsuloligamentous tissue of the glenohumeral joint is tensile-tested in the apprehension position, there is only slight anterior band strain and failure occurring, predominantly at the glenoid insertion site. This has implications For the success of surgical procedures designed for acute repair of Bankart lesions.
引用
收藏
页码:473 / 479
页数:7
相关论文
共 40 条
[1]   TENSILE PROPERTIES OF HUMAN KNEE-JOINT CARTILAGE .1. INFLUENCE OF IONIC CONDITIONS, WEIGHT BEARING, AND FIBRILLATION ON THE TENSILE MODULUS [J].
AKIZUKI, S ;
MOW, VC ;
MULLER, F ;
PITA, JC ;
HOWELL, DS ;
MANICOURT, DH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1986, 4 (04) :379-392
[2]   DISRUPTION OF THE LATERAL CAPSULE OF THE SHOULDER - A CAUSE OF RECURRENT DISLOCATION [J].
BACH, BR ;
WARREN, RF ;
FRONEK, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (02) :274-276
[3]   The pathology and treatment of recurrent dislocation of the shoulder-joint [J].
Bankart, ASB .
BRITISH JOURNAL OF SURGERY, 1938, 26 (101) :23-29
[4]   Recurrent or habitual dislocation of the shoulder-joint [J].
Bankart, ASB .
BRITISH MEDICAL JOURNAL, 1923, 1923 :1132-1133
[5]   TENSILE PROPERTIES OF THE INFERIOR GLENOHUMERAL LIGAMENT [J].
BIGLIANI, LU ;
POLLOCK, RG ;
SOSLOWSKY, LJ ;
FLATOW, EL ;
PAWLUK, RJ ;
MOW, VC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (02) :187-197
[6]   INFERIOR CAPSULAR SHIFT PROCEDURE FOR ANTERIOR-INFERIOR SHOULDER INSTABILITY IN ATHLETES [J].
BIGLIANI, LU ;
KURZWEIL, PR ;
SCHWARTZBACH, GC ;
WOLFE, IN ;
FLATOW, EL .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (05) :578-584
[7]  
BROCA A, 1890, B SOC ANAT PARIS, V65, P312
[8]   DYNAMIC PERFORMANCE-CHARACTERISTICS OF THE LIQUID-METAL STRAIN-GAUGE [J].
BROWN, TD ;
SIGAL, L ;
NJUS, GO ;
NJUS, NM ;
SINGERMAN, RJ ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1986, 19 (02) :165-173
[9]   ANTERIOR STABILITY OF THE GLENOHUMERAL JOINT - A DYNAMIC-MODEL [J].
CAIN, PR ;
MUTSCHLER, TA ;
FU, FH ;
LEE, SK .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1987, 15 (02) :144-148
[10]   ABDUCTION OF ARM IN SCAPULAR PLANE - SCAPULAR AND GLENOHUMERAL MOVEMENTS - A ROENTGENOGRAPHIC STUDY [J].
FREEDMAN, L ;
MUNRO, RR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1966, A 48 (08) :1503-&