Safety and efficacy of hybrid vascular closure technique using both a suture- and collagen-mediated closure device after transfemoral transcatheter aortic valve implantation

被引:8
作者
Al-Ani, Ahmed [1 ]
Hoffmann, Pavel [1 ]
von Lueder, Thomas [2 ]
Opdahl, Anders [1 ]
机构
[1] Oslo Univ Hosp, Div Cardiovasc & Pulm Dis, Sect Intervent Cardiol Ulleval, Dept Cardiol, Postboks 4950 Nydalen, N-0424 Oslo, Norway
[2] Oslo Univ Hosp, Div Med, Dept Cardiol, Oslo, Norway
关键词
AVDP-aortic valve disease; percutaneous intervention; TVI-transcatheter valve implantation; VCLO-vascular closure; ACCESS SITE CLOSURE; LARGE-BORE ACCESS; COMPLICATIONS; OUTCOMES; REPLACEMENT; PROGLIDE;
D O I
10.1002/ccd.28419
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To evaluate the clinical utility and feasibility of a hybrid technique for obtaining vascular hemostasis by combining a suture- and a collagen-mediated system after transfemoral transcatheter aortic valve implantation (TF TAVI) in a real-world setting. Methods In 75 consecutive TF TAVI procedures, we investigated a hybrid closing method to achieve hemostasis at the large bore puncture site using a combination of one presuture closure system (ProGlide) and one collagen-mediated system (Angio-Seal). Vascular complications at puncture site were recorded until discharge. Results Successful hemostasis by the hybrid technique was achieved in 74 out of 75 patients, and the method was well tolerated by all patients. In 73 patients, (97.3%) neither puncture site related complications nor serious early or late bleedings were observed during a median hospital stay of 2 days postprocedure. Conclusion This single-center registry study indicates that a percutaneous hybrid closure technique is safe and efficacious in closing large bore arteriotomies. It is an easy and reliable technique that may contribute to simplifying TAVI procedures. Study registration The data was collected from an internal quality control registry on treatment of patients with valvular heart disease with or without coronary artery disease, No 2014/17280, Oslo University Hospital, Ulleval.
引用
收藏
页码:1171 / 1175
页数:5
相关论文
共 17 条
[1]  
Amponsah MK, 2017, INT J ANGIOL, V26, P116, DOI 10.1055/s-0037-1598252
[2]   MANTA versus ProGlide vascular closure devices in transfemoral transcatheter aortic valve implantation [J].
Biancari, Fausto ;
Romppanen, Hannu ;
Savontaus, Mikko ;
Siljander, Antti ;
Makikallio, Timo ;
Piira, Olli-Pekka ;
Piuhola, Jarkko ;
Vilkki, Viivi ;
Ylitalo, Antti ;
Vasankari, Tuija ;
Airaksinen, Juhani K. E. ;
Niemela, Matti .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 263 :29-31
[3]   Impact of percutaneous femoral arteriotomy closure using the MANTATM device on vascular and bleeding complications after transcatheter aortic valve replacement [J].
De Palma, Rodney ;
Settergren, Magnus ;
Ruck, Andreas ;
Linder, Rikard ;
Saleh, Nawzad .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (05) :954-961
[4]   Simple, Effective and Safe Vascular Access Site Closure with the Double-ProGlide Preclose Technique in 162 Patients Receiving Transfemoral Transcatheter Aortic Valve Implantation [J].
Griese, Daniel P. ;
Reents, Wilko ;
Diegeler, Anno ;
Kerber, Sebastian ;
Babin-Ebell, Joerg .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (05) :E734-E741
[5]  
Hoffmann P, 2018, CVIR ENDOVASCULAR, V1, P1
[6]   Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery. [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael ;
Miller, D. Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Brown, David L. ;
Block, Peter C. ;
Guyton, Robert A. ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Douglas, Pamela S. ;
Petersen, John L. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (17) :1597-1607
[7]  
Maniotis C, 2017, CARDIOVASC REVASCULA, V18, P145, DOI 10.1016/j.carrev.2016.11.004
[8]   Incidence, Predictors, and Mid-Term Outcomes of Percutaneous Closure Failure After Transfemoral Aortic Valve Implantation Using an Expandable Sheath (from the Optimized Transcatheter Valvular Intervention [OCEAN-TAVI] Registry) [J].
Nara, Yugo ;
Watanabe, Yusuke ;
Kozuma, Ken ;
Kataoka, Akihisa ;
Nakashima, Makoto ;
Hioki, Hirofumi ;
Kawashima, Hideyuki ;
Nagura, Fukuko ;
Shirai, Shinichi ;
Tada, Norio ;
Araki, Motoharu ;
Naganuma, Toru ;
Yamanaka, Futoshi ;
Yamamoto, Masanori ;
Hayashida, Kentaro .
AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (04) :611-617
[9]   Plug vs. suture: Who wins in large bore access closure? [J].
Shatila, Wassim ;
Krajcer, Zvonimir .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (05) :962-963
[10]   Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients [J].
Smith, Craig R. ;
Leon, Martin B. ;
Mack, Michael J. ;
Miller, Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Williams, Mathew ;
Dewey, Todd ;
Kapadia, Samir ;
Babaliaros, Vasilis ;
Thourani, Vinod H. ;
Corso, Paul ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (23) :2187-2198