New sporopollenin-based β-cyclodextrin functionalized magnetic hybrid adsorbent for magnetic solid-phase extraction of nonsteroidal anti-inflammatory drugs from water samples

被引:18
|
作者
Yaacob, Syed Fariq Fathullah Syed [1 ]
Kamboh, Muhammad Afzal [3 ]
Ibrahim, Wan Aini Wan [4 ]
Mohamadu, Sharifah [1 ,2 ]
机构
[1] Univ Malaya, Fac Sci, Dept Chem, Kuala Lumpur, Malaysia
[2] Univ Malaya, UMCiL, Kuala Lumpur, Malaysia
[3] Shaheed Benazir Bhutto Univ, Dept Chem, Shaheed Benazirabad, Sindh, Pakistan
[4] Univ Teknol Malaysia, Fac Sci, Dept Chem, Separat Sci & Technol Grp SepSTec, Johor Baharu, Johor, Malaysia
来源
ROYAL SOCIETY OPEN SCIENCE | 2018年 / 5卷 / 07期
关键词
sporopollenin; magnetic nanoparticles; beta-cyclodextrin; NSAIDs; magnetic solid-phase extraction; POLYCYCLIC AROMATIC-HYDROCARBONS; ORGANOPHOSPHORUS PESTICIDES; ENVIRONMENTAL WATER; AQUEOUS-SOLUTION; HUMAN URINE; NANOPARTICLES; CHROMATOGRAPHY; REMOVAL; MICROEXTRACTION; SEPARATION;
D O I
10.1098/rsos.171311
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A magnetic solid-phase extraction (MSPE) procedure on the newly synthesized magnetic beta-cyclodextrin functionalized wi th toluene diisocyanate (TDI) as a linker arid further modified with bio-polymeric spores of sporopollenin (MSp-TDI-beta CD), was developed for the extraction of nonsteroidal anti-inflammatory drugs (NSAIDs), namely, indoprofen (INP), ketoprofen (KTP), ibuprofen (IBP) and fenoprofen (FNP) from water samples prior to their HPLC-DAD determination. The newly synthesized MSp-TDI-beta CD was comprehensibly characterized using FT-IR, XRD, SEM-EDX, BET and VSM analyses. The separation of selected NSAIDs on MSp-TDI-beta CD from aqueous solution was simply achieved by applying an external magnetic field via a permanent magnet. The MSPE parameters affecting extraction performance, i.e. sorbent do sage, sample volume, extraction and desorption time, type of organic eluent and volume and solution pH were investigated and optimized. The proposed method showed linear range between 0.5 and 500 ng ml(-1), low limit of detection at S/N = 3 (0.16-0.37 ng ml(-1)) and limit of quantification at S/N = 10 (0.53-1.22 ng ml(-1)). The inter-day (n = 15) and intra-day (n = 5) precision for the proposed methods given by relative standard deviation (RSD%) was in the range of 2.5-4.0 and 2.1-5.5, respectively. The extraction recoveries of NSAIDs from environmental samples (tap, drinking and river water) ranged from 92.5% to 123.6%, with satisfactory precision (RSD% less than 12.4%).
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Rapid and simple magnetic solid-phase extraction of bisphenol A from bottled water, baby bottle, and urine samples using green magnetic hydroxyapatite/β-cyclodextrin polymer nanocomposite
    Bayatloo, Mohammad Reza
    Nojavan, Saeed
    MICROCHEMICAL JOURNAL, 2022, 175
  • [42] Magnetic dispersive solid-phase extraction of triazole and triazine pesticides from vegetable samples using a hydrophilic-lipophilic sorbent based on maltodextrin- and β-cyclodextrin-functionalized graphene oxide
    Majd, Mahshid
    Nojavan, Saeed
    MICROCHIMICA ACTA, 2021, 188 (11)
  • [43] New chrysin-functionalized silica-core shell magnetic nanoparticles for the magnetic solid phase extraction of copper ions from water samples
    Ali, Layth Imad Abd
    Ibrahim, Wan Aini Wan
    Sulaiman, Azli
    Kamboh, Muhammad Afzal
    Sanagi, Mohd Marsin
    TALANTA, 2016, 148 : 191 - 199
  • [44] Magnetic coffee residue as sorbent for magnetic solid-phase extraction and determination of titanium dioxide nanoparticles in water samples
    Firomesa, Hundera
    Amde, Meseret
    Bekana, Deribachew
    Temesgen, Ayalew
    CHEMICAL PAPERS, 2022, 76 (04) : 2267 - 2277
  • [45] 1-Octyl-3-methylimidazolium hexafluorophosphate-functionalised magnetic poly β-cyclodextrin for magnetic solid-phase extraction ofpyrethroids from tea infusions
    Xu, Qinqin
    Liu, Zikai
    Yan, Chen
    Lu, Runhua
    Zhou, Wenfeng
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (10): : 1743 - 1754
  • [46] Magnetic polydopamine modified with deep eutectic solvent for the magnetic solid-phase extraction of sulfonylurea herbicides in water samples
    Wang, Dan-Dan
    Zhao, Yue
    Yang, Mei-Nan Ou
    Guo, Hao-Ming
    Yang, Zhong-Hua
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1601 : 53 - 59
  • [47] Use of hydroxypropyl β-cyclodextrin hybrid monolithic material as adsorbent for dispersive solid-phase extraction of fluoroquinolones from environmental water samples
    Zhou, Li
    Yu, Jia
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (13) : 2310 - 2320
  • [48] Magnetic reduced graphene oxide functionalized with β-cyclodextrin as magnetic solid-phase extraction adsorbents for the determination of phytohormones in tomatoes coupled with high performance liquid chromatography
    Li, Na
    Chen, Juan
    Shi, Yan-Ping
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1441 : 24 - 33
  • [49] Magnetic nanoparticle of metal-organic framework with core-shell structure as an adsorbent for magnetic solid phase extraction of non-steroidal anti-inflammatory drugs
    Liu, Siyu
    Li, Shuo
    Yang, Wei
    Gu, Fan
    Xu, Haiyan
    Wang, Ting
    Sun, Duhong
    Hou, Xiaohong
    TALANTA, 2019, 194 : 514 - 521
  • [50] Magnetic polyethyleneimine functionalized reduced graphene oxide as a novel magnetic solid-phase extraction adsorbent for the determination of polar acidic herbicides in rice
    Li, Na
    Chen, Juan
    Shi, Yan-Ping
    ANALYTICA CHIMICA ACTA, 2017, 949 : 23 - 34