Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors

被引:9
|
作者
Tanoue, Shota [1 ]
Nakaura, Takeshi [1 ]
Nagayama, Yasunori [1 ]
Uetani, Hiroyuki [1 ]
Ikeda, Osamu [1 ]
Yamashita, Yasuyuki [1 ]
机构
[1] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Honjo 1-1-1, Kumamoto, Kumamoto 8608556, Japan
关键词
Tomography; X-ray computed; Radiography; Dual-energy scanned projection; Image enhancement; Brain neoplasms; HEAD CT; 120; KVP; RECONSTRUCTION; CONTRAST; HEMORRHAGE; VOLTAGE;
D O I
10.3348/kjr.2020.0677
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. Materials and Methods: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale. Results: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01). Conclusion: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.
引用
收藏
页码:951 / 958
页数:8
相关论文
共 50 条
  • [21] Evaluation of virtual monochromatic imaging with dual-energy computed tomography of small liver metastases from malignant abdominal tumours: Quantitative and qualitative analyses
    Okada, Hiroaki
    Matsunaga, Nozomu
    Yamamoto, Takahiro
    Yamauchi, Masato
    Suzuki, Kojiro
    ACTA RADIOLOGICA OPEN, 2023, 12 (12)
  • [22] Dual-energy computed tomography in acute ischemic stroke: state-of-the-art
    Mangesius, Stephanie
    Janjic, Tanja
    Steiger, Ruth
    Haider, Lukas
    Rehwald, Rafael
    Knoflach, Michael
    Widmann, Gerlig
    Gizewski, Elke
    Grams, Astrid
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 4138 - 4147
  • [23] Unsupervised deep learning based image outpainting for dual-source, dual-energy computed tomography
    Liu, Chi-Kuang
    Huang, Hsuan-Ming
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [24] Image Quality on Dual-energy CTPA Virtual Monoenergetic Images: Quantitative and Qualitative Assessment
    Dane, Bari
    Patel, Hersh
    O'Donnell, Thomas
    Girvin, Francis
    Brusca-Augello, Geraldine
    Alpert, Jeffrey B.
    Niu, Bowen
    Attia, Mariam
    Babb, James
    Ko, Jane P.
    ACADEMIC RADIOLOGY, 2018, 25 (08) : 1075 - 1086
  • [25] Dual-Energy Computed Tomography Applications in Lung Cancer
    Hartley-Blossom, Zachary J.
    Digumarthy, Subba R.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 987 - 994
  • [26] Improved detectability of hypoattenuating focal pancreatic lesions by dual-layer computed tomography using virtual monoenergetic images
    El Kayal, Nada
    Mohallel, Ahmed
    Maintz, David
    Eid, Mohamed
    Emara, Doaa Mokhtar
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01)
  • [27] Clinical Applications of Dual-Energy Computed Tomography for Acute Ischemic Stroke
    Chen, Huanwen
    Bodanapally, Uttam K.
    Colasurdo, Marco
    Malhotra, Ajay
    Gandhi, Dheeraj
    STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2024, 4 (02):
  • [28] Physics-informed Deep Learning for Dual-Energy Computed Tomography Image Processing
    Poirot, Maarten G.
    Bergmans, Rick H. J.
    Thomson, Bart R.
    Jolink, Florine C.
    Moum, Sarah J.
    Gonzalez, Ramon G.
    Lev, Michael H.
    Tan, Can Ozan
    Gupta, Rajiv
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [29] Dual-layer spectral computed tomography: measuring relative electron density
    Mei K.
    Ehn S.
    Oechsner M.
    Kopp F.K.
    Pfeiffer D.
    Fingerle A.A.
    Pfeiffer F.
    Combs S.E.
    Wilkens J.J.
    Rummeny E.J.
    Noël P.B.
    European Radiology Experimental, 2 (1)
  • [30] Development of a dual-energy computed tomography quality control program: Characterization of scanner response and definition of relevant parameters for a fast-kVp switching dual-energy computed tomography system
    Nute, Jessica L.
    Jacobsen, Megan C.
    Stefan, Wolfgang
    Wei, Wei
    Cody, Dianna D.
    MEDICAL PHYSICS, 2018, 45 (04) : 1444 - 1458