Fat suppression at 2D MR imaging of the hands: Dixon method versus CHESS technique and STIR sequence

被引:25
作者
Kirchgesner, Thomas [1 ]
Perlepe, Vasiliki [1 ]
Michoux, Nicolas [1 ]
Larbi, Ahmed [1 ]
Berg, Bruno Vande [1 ]
机构
[1] Catholic Univ Louvain, Clin Univ St Luc, IREC, Musculoskeletal Imaging Unit, Ave Hippocrate 10, B-1200 Brussels, Belgium
关键词
MRI; Fat; Dixon; IDEAL; Artifacts; Hands; TAU INVERSION-RECOVERY; RHEUMATOID-ARTHRITIS; MUSCULOSKELETAL SYSTEM; BRACHIAL-PLEXUS; RICE PADS; 3.0; T; WATER; IDEAL; SEPARATION; SPINE;
D O I
10.1016/j.ejrad.2017.01.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the effectiveness of fat suppression and the signal-to-noise ratio (SNR) of the Dixon method with those of the CHESS (Chemical Shift-Selective) technique and STIR (Short Tau Inversion Recovery) sequence in hands of normal subjects at 2D MR imaging. Material and methods: 14 healthy volunteers (mean age of 29.4 years) consented to have both hands prospectively imaged with SE T1 Dixon, T1 CHESS, T2 Dixon, T2 CHESS and STIR sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFSBm) and soft tissues (EFSST) in 20 joints per subject. One radiologist measured the SNR in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects, paired t-test and observed agreement to assess differences in effectiveness of fat suppression, differences in SNR and inter-observer agreement. Results: EFSBM was statistically significantly higher for T1 Dixon than for T1 CHESS and for T2 Dixon than for T2 CHESS (p < 0.0001). EFSBM was significantly higher for T2 Dixon than for STIR in the coronal plane (p = 0.0020). The SNR was significantly higher for T1 Dixon than for T1 CHESS and for T2 Dixon than for STIR (p < 0.0001). The SNR was significantly lower for T2 Dixon than for T2 CHESS (p < 0.0001). Conclusion: The Dixon method yields more effective fat suppression and higher SNR than the CHESS technique at 2D TI-weighted MR imaging of the hands. At T2-weighted MR imaging, fat suppression is more effective with the Dixon method while SNR is higher with the CHESS technique. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 22 条
[21]   Usefulness of IDEAL T2 imaging for homogeneous fat suppression and reducing susceptibility artefacts in brachial plexus MRI at 3.0 T [J].
Tagliafico, Alberto ;
Bignotti, Bianca ;
Tagliafico, Giulio ;
Martinoli, Carlo .
RADIOLOGIA MEDICA, 2016, 121 (01) :45-53
[22]   Short tau inversion recovery and three-point Dixon water-fat separation sequences in acute traumatic bone fractures at open 0.35 tesia MRI [J].
Wohlgemuth, WA ;
Roemer, FW ;
Bohndorf, K .
SKELETAL RADIOLOGY, 2002, 31 (06) :343-348