Reliability of reference distances used in photogrammetry

被引:17
|
作者
Aksu, Muge [1 ]
Kaya, Demet
Kocadereli, Ilken [1 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Orthodont, TR-06100 Ankara, Turkey
关键词
Photogrammetry; Reference distances; TISSUE FACIAL PROFILE; ORTHOGNATHIC SURGERY; SURGICAL-CORRECTION; NASAL CHANGES; ASYMMETRY; PHOTOGRAPHS; DEFORMITIES; SYSTEM; ADULTS; FACES;
D O I
10.2319/070309-372.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To determine the reliability of the reference distances used for photogrammetric assessment. Materials and Methods: The sample consisted of 100 subjects with mean ages of 22.97 +/- 2.98 years. Five lateral and four frontal parameters were measured directly on the subjects' faces. For photogrammetric assessment, two reference distances for the profile view and three reference distances for the frontal view were established. Standardized photographs were taken and all the parameters that had been measured directly on the face were measured on the photographs. The reliability of the reference distances was checked by comparing direct and indirect values of the parameters obtained from the subjects' faces and photographs. Repeated measure analysis of variance (ANOVA) and Bland-Altman analyses were used for statistical assessment. Results: For profile measurements, the indirect values measured were statistically different from the direct values except for Sn-Sto in male subjects and Prn-Sn and Sn-Sto in female subjects. The indirect values of Prn-Sn and Sn-Sto were reliable in both sexes. The poorest results were obtained in the indirect values of the N-Sn parameter for female subjects and the Sn-Me parameter for male subjects according to the Sa-Sba reference distance. For frontal measurements, the indirect values were statistically different from the direct values in both sexes except for one in male subjects. The indirect values measured were not statistically different from the direct values for Go-Go. The indirect values of Ch-Ch were reliable in male subjects. The poorest results were obtained according to the P-P reference distance. Conclusions: For profile assessment, the T-Ex reference distance was reliable for Prn-Sn and Sn-Sto in both sexes. For frontal assessment, Ex-Ex and En-En reference distances were reliable for Ch-Ch in male subjects. (Angle Orthod. 2010;80:670-677.)
引用
收藏
页码:670 / 677
页数:8
相关论文
共 50 条
  • [1] Generalized reliability based on distances
    Xu, Meng
    Reiss, Philip T.
    Cribben, Ivor
    BIOMETRICS, 2021, 77 (01) : 258 - 270
  • [2] Reliability of frames of reference used for tibial component rotation in total knee arthroplasty
    Page, Stephen R.
    Deakin, Angela H.
    Payne, Anthony P.
    Picard, Frederic
    COMPUTER AIDED SURGERY, 2011, 16 (02) : 86 - 92
  • [3] An assessment of the reliability and standardisation of tests used to elicit reference muscular actions for electromyographical normalisation
    Ball, N.
    Scurr, J.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2010, 20 (01) : 81 - 88
  • [4] Reference Station of Aerial Photogrammetry with GPS/INS by VRS
    Song, Taemin
    Kwon, Jay Hyoun
    KOREAN JOURNAL OF REMOTE SENSING, 2008, 24 (04) : 381 - 388
  • [5] Efficient detection and recognition algorithm of reference points in photogrammetry
    Li, Weimin
    Liu, Gang
    Zhu, Lichun
    Li, Xiaofeng
    Zhang, Yuhai
    Shan, Siyu
    OPTICS, PHOTONICS AND DIGITAL TECHNOLOGIES FOR IMAGING APPLICATIONS IV, 2016, 9896
  • [6] Reliability of Using Stereo Photogrammetry to Estimate Modal Parameters
    Sabino, Danilo Damasceno
    Poozesh, Peyman
    Pereira, Joao Antonio
    Niezrecki, Christopher
    TOPICS IN MODAL ANALYSIS & TESTING, VOL 10, 2017, : 147 - 151
  • [7] RELIABILITY INDEXES OF POPLITEAL ANGLE ANALYSIS THROUGH PHOTOGRAMMETRY
    Duarte, Ricardo B.
    Romanatti, Sandro V.
    Gongora, Helcio
    Antonietti, Leandro Stetner
    Pires, Leonardo
    Cohen, Moises
    REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2014, 20 (06) : 416 - 420
  • [8] ANALYSIS OF THE RELIABILITY AND REPRODUCIBILITY OF GONIOMETRY COMPARED TO HAND PHOTOGRAMMETRY
    Ferreira de Carvalho, Rosana Martins
    Mazzer, Nilton
    Barbieri, Claudio Henrique
    ACTA ORTOPEDICA BRASILEIRA, 2012, 20 (03): : 139 - 149
  • [9] RATIONALIZED SURVEYING - PHOTOGRAMMETRY USED IN AUSTRIAN MONUMENT PROTECTION
    FORAMITT.H
    PHOTOGRAMMETRIC ENGINEERING, 1970, 36 (06): : 591 - &
  • [10] Computerized Photogrammetry Used to Calculate the Brow Position Index
    Naif Thadeu Naif-de-Andrade
    Bernardo Hochman
    Camila Zirlis Naif-de-Andrade
    Lydia Masako Ferreira
    Aesthetic Plastic Surgery, 2012, 36 : 1047 - 1051