A parallelizable real-time motion tracking algorithm with applications to ultrasonic strain imaging

被引:58
作者
Jiang, J. [1 ]
Hall, T. J. [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
关键词
D O I
10.1088/0031-9155/52/13/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasound-based mechanical strain imaging systems utilize signals from conventional diagnostic ultrasound systems to image tissue elasticity contrast that provides new diagnostically valuable information. Previous works ( Hall et al 2003 Ultrasound Med. Biol. 29 427, Zhu and Hall 2002 Ultrason. Imaging 24 161) demonstrated that uniaxial deformation with minimal elevation motion is preferred for breast strain imaging and real-time strain image feedback to operators is important to accomplish this goal. The work reported here enhances the real-time speckle tracking algorithm with two significant modifications. One fundamental change is that the proposed algorithm is a column-based algorithm (a column is defined by a line of data parallel to the ultrasound beam direction, i.e. an A-line), as opposed to a row-based algorithm ( a row is defined by a line of data perpendicular to the ultrasound beam direction). Then, displacement estimates from its adjacent columns provide good guidance for motion tracking in a significantly reduced search region to reduce computational cost. Consequently, the process of displacement estimation can be naturally split into at least two separated tasks, computed in parallel, propagating outward from the center of the region of interest ( ROI). The proposed algorithm has been implemented and optimized in a WindowsR (R) system as a stand-alone ANSIC++ program. Results of preliminary tests, using numerical and tissue-mimicking phantoms, and in vivo tissue data, suggest that high contrast strain images can be consistently obtained with frame rates (10 frames s(-1)) that exceed our previous methods.
引用
收藏
页码:3773 / 3790
页数:18
相关论文
共 38 条
[1]   QUANTITATIVE TISSUE MOTION ANALYSIS OF DIGITIZED M-MODE IMAGES - GESTATIONAL DIFFERENCES OF FETAL LUNG [J].
ADLER, RS ;
RUBIN, JM ;
BLAND, PH ;
CARSON, PL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (06) :561-569
[2]  
Bamber JC, 1996, ACOUST IMAG, V22, P285
[3]   Quantitative elasticity imaging: what can and cannot be inferred from strain images [J].
Barbone, PE ;
Bamber, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (12) :2147-2164
[4]   Error analysis in acoustic elastography .1. Displacement estimation [J].
Bilgen, M ;
Insana, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (02) :1139-1146
[5]   Target detectability in acoustic elastography [J].
Bilgen, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (05) :1128-1133
[6]   2-D motion estimation using two parallel receive beams [J].
Bohs, LN ;
Gebhart, SC ;
Anderson, ME ;
Geiman, BJ ;
Trahey, GE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (02) :392-408
[7]   METHODS FOR ESTIMATION OF SUBSAMPLE TIME DELAYS OF DIGITIZED ECHO SIGNALS [J].
CESPEDES, I ;
HUANG, Y ;
OPHIR, J ;
SPRATT, S .
ULTRASONIC IMAGING, 1995, 17 (02) :142-171
[8]   2-D companding for noise reduction in strain imaging [J].
Chaturvedi, P ;
Insana, MF ;
Hall, TJ .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) :179-191
[9]   EXPERIMENTAL EVALUATION OF THE CORRELATION INTERPOLATION TECHNIQUE TO MEASURE REGIONAL TISSUE VELOCITY [J].
DEJONG, PGM ;
ARTS, T ;
HOEKS, APG ;
RENEMAN, RS .
ULTRASONIC IMAGING, 1991, 13 (02) :145-161
[10]   Intravascular elasticity imaging using ultrasound: Feasibility studies in phantoms [J].
deKorte, CL ;
Cespedes, EI ;
vanderSteen, AFW ;
Lancee, CT .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) :735-746