DETERMINATION AND CHARACTERIZATION OF SELECTED FLUOROQUINOLONES OXIDATION PRODUCTS UNDER POTASSIUM PERMANGANATE TREATMENT

被引:0
作者
Hubicka, Urszula [1 ]
Zmudzki, Pawel [2 ]
Zuromska-Witek, Barbara [1 ]
Zajdel, Pawel [2 ]
Krzek, Jan [1 ]
机构
[1] Jagiellonian Univ, Coll Med, Fac Pharm, Dept Inorgan & Analyt Chem, 9 Med St, PL-30688 Krakow, Poland
[2] Jagiellonian Univ, Coll Med, Fac Pharm, Dept Med Chem, PL-30688 Krakow, Poland
来源
ACTA POLONIAE PHARMACEUTICA | 2015年 / 72卷 / 06期
关键词
fluoroquinolones; oxidation; kinetic evaluation; UPLC-MS/MS; ALKALINE PERMANGANATE; ANTIBACTERIAL AGENTS; ENROFLOXACIN; DEGRADATION; OZONATION; TRANSFORMATION; CIPROFLOXACIN; NORFLOXACIN; KINETICS; OZONE;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A simple, sensitive and reproducible ultra-performance liquid chromatography (UPLC) method for the determination of: danofloxacin. enrofloxacin, marbofloxacin, orbifloxacin and pefloxacin oxidation stability under permanganate treatment in acidic conditions at pH from 3.0 to 6.0, was developed. Chromatographic separations were carried out using the Acquity UPLC BEH C-18 column; (2.1 x 100 mm, 1.7 mu m particle size). The column was maintained at 40 degrees C, and eluted under gradient conditions using from 100% to 75% of eluent A over 10 min for danofloxacin, enrofloxacin, marbofloxacin, orbifloxacin or 95% to 75% of eluent A over 10 min for pefloxacin, at a flow rate of 0.3 mL/min. Eluent A: 1% (v/v) formic acid in water; eluent B: 0.1% (v/v) formic acid in acetonitrile. Satisfactory resolution was obtained for oxidation products. The correlation coefficients and determination coefficients (R-2) obtained for linear model for all examined fluoroquinolones were greater than 0.99. Linearity range was observed in the concentration range 0.06-0.13 mg/mL. Sensitivity of the method was good. The LOD and LOQ values were found to be 0.01 mg/mL and from 0.02 to 0.04 mg/mL, respectively. Good precision and intermediate precision with %RSD less than 2.0% was observed. The oxidation processes followed kinetic of the second order reaction and depended upon solution acidity. Oxidation of fluoroquinolones proceeded at piperazine moiety yielding respective hydroxy and oxo analogs, and leaving the quinolone fragment intact. Structures of products formed were assigned on a basis of UPLC/MS/MS fragmentation pathways.
引用
收藏
页码:1101 / 1114
页数:14
相关论文
共 38 条
[31]   Wet carbon-based solid acid/potassium permanganate as an efficient heterogeneous reagents for oxidation of alcohols under mild conditions [J].
Shokrolahi, Arash ;
Zali, Abbas ;
Keshavarz, Mohammad Hossein .
CHINESE CHEMICAL LETTERS, 2008, 19 (11) :1274-1276
[32]   Silica sulfuric acid/potassium permanganate/wet SiO2 as an efficient heterogeneous method for the oxidation of alcohols under mild conditions [J].
Mirjalili, BF ;
Zolfigol, MA ;
Bamoniri, A ;
Zarei, A .
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2003, 24 (03) :400-402
[33]   Ozone oxidation of antidepressants in wastewater –Treatment evaluation and characterization of new by-products by LC-QToFMS [J].
André Lajeunesse ;
Mireille Blais ;
Benoît Barbeau ;
Sébastien Sauvé ;
Christian Gagnon .
Chemistry Central Journal, 7
[34]   Hydrothermal treatment of microcrystalline cellulose under mild conditions: characterization of solid and liquid-phase products [J].
Seehra, M. S. ;
Popp, B. V. ;
Goulay, F. ;
Pyapalli, S. K. ;
Gullion, T. ;
Poston, J. .
CELLULOSE, 2014, 21 (06) :4483-4495
[35]   Trace determination of peptides in water samples using packed capillary liquid chromatography with UV and MS detection and characterization of peptide oxidation products by MS [J].
Thomas Bjellaas ;
Anders Holm ;
Paal Molander ;
John Aasulf Tørnes ;
Tyge Greibrokk ;
Elsa Lundanes .
Analytical and Bioanalytical Chemistry, 2004, 378 :1021-1030
[36]   Trace determination of peptides in water samples using packed capillary liquid chromatography with UV and MS detection and characterization of peptide oxidation products by MS [J].
Bjellaas, T ;
Holm, A ;
Molander, P ;
Tornes, JA ;
Greibrokk, T ;
Lundanes, E .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (04) :1021-1030
[37]   Characterization of polysorbate 80 with liquid chromatography mass spectrometry and nuclear magnetic resonance spectroscopy: Specific determination of oxidation products of thermally oxidized polysorbate 80 [J].
Hvattum, Erlend ;
Yip, Wai Lam ;
Grace, David ;
Dyrstad, Knut .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 62 :7-16
[38]   Development and Validation of Stability-Indicating HPLC Methods for the Estimation of Lomefloxacin and Balofloxacin Oxidation Process under ACVA, H2O2, or KMnO4 Treatment. Kinetic Evaluation and Identification of Degradation Products by Mass Spectrometry [J].
Zuromska-Witek, Barbara ;
Zmudzki, Pawel ;
Szlosarczyk, Marek ;
Maslanka, Anna ;
Hubicka, Urszula .
MOLECULES, 2020, 25 (22)