A new flexible reconstruction framework for motion correction in SPECT imaging

被引:8
作者
Schumacher, Hanno [1 ]
Fischer, Bernd [1 ]
机构
[1] Univ Lubeck, Inst Math, D-23554 Lubeck, Germany
关键词
data-driven motion correction; reconstruction algorithm; SPECT;
D O I
10.1109/TNS.2007.896211
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to the long imaging times in SPECT, patient motion is inevitable and constitutes a serious problem for any reconstruction algorithm. The measured inconsistent projection data lead to reconstruction artifacts which can significantly affect the diagnostic accuracy of SPECT if not corrected. Among the most, promising attempts for addressing this cause of artifficts is the so-called data-driven motion correction methodology, implemented, for example, in the OSEM scheme. At present, this algorithm is restricted to the exclusive use of a dual-head SPECT system with perpendicular heads and incorporating* in a subset only projection data obtained between a patient movement. The utilization within other SPECT systems may lead to unsatisfactory results. In this note we present a new reconstruction framework which overcomes these two shortcomings. Within the new framework, the user may choose any set of projection for the reconstruction and the scheme works for any SPECT system. As a byproduct, the well-known EM and OSEM reconstruction schemes may be written in terms of the new framework and therefore are included in the theoretical considerations. The paper is supplemented by a large set of test examples, underscoring the potential power of the proposed novel approach. Using both an academic example and images from a double-head detector we studied the extent of defects induced by simulated motion and validated the new schemes.
引用
收藏
页码:480 / 485
页数:6
相关论文
共 21 条
[1]  
BOTVINICK EH, 1993, J NUCL MED, V34, P303
[2]  
Bruyant PP, 2002, J NUCL MED, V43, P1343
[3]  
Chen Q., 1993, J NUCL MED TECHNOL, V21, P198
[4]  
COOPER JA, 1992, J NUCL MED, V33, P1566
[5]   Use of three-dimensional Gaussian interpolation in the projector/backprojector pair of iterative reconstruction for compensation of known rigid-body motion in SPECT [J].
Feng, Bing ;
Gifford, Howard C. ;
Beach, Richard D. ;
Boening, Guido ;
Gennert, Michael A. ;
King, Michael A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :838-844
[6]  
FRIEDMAN J, 1989, J NUCL MED, V30, P1718
[7]  
FULTON R, 2005, P IEEE NUCL SCI S ME
[8]   A practical 3D tomographic method for correcting patient head motion in clinical SPECT [J].
Fulton, RR ;
Eberl, S ;
Meikle, SR ;
Hutton, BF ;
Braun, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :667-672
[9]  
Golub GH, 2013, Matrix Computations, V4
[10]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609