Magnetic resonance imaging at high magnetic fields

被引:0
|
作者
Fitzsimmons, JR [1 ]
Duensing, GR [1 ]
Peterson, DM [1 ]
机构
[1] Univ Florida, Dept Radiol, Gainesville, FL 32601 USA
关键词
magnetic resonance imaging; high magnetic fields; radio frequency probes; coils;
D O I
10.1117/12.300053
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic Resonance imaging (MRI) has made significant advances since its introduction over fifteen years ago. The technology has been driven by a combination of higher magnetic fields, more efficient pulse sequence design and technical advances in transducer technology associated with the capture of weak magnetic resonance signals. This paper explores those advances with particular emphasis on state of the art high field MRI systems and the latest radio frequency (RF) transducers or RF coils as they are commonly referred to. The design and construction of large bore (human body sized) magnets operating at high magnetic fields (3 Tesla and above) has been the special purview of a limited number of engineering companies while the design and construction of RF coils has been addressed by a wider range of physicists and engineers working at major universities as well as those engineers working within industry. Our work at the University of Florida has been mainly focused on developing these RF coils to address the unique problems presented by operating at high magnetic fields and frequencies.
引用
收藏
页码:156 / 167
页数:12
相关论文
共 50 条
  • [31] A practical guide to in vivo proton magnetic resonance spectroscopy at high magnetic fields
    Xin, Lijing
    Tkac, Ivan
    ANALYTICAL BIOCHEMISTRY, 2017, 529 : 30 - 39
  • [32] Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields
    Cassidy, PJ
    Schneider, JE
    Grieve, SM
    Lygate, C
    Neubauer, S
    Clarke, K
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (02) : 229 - 237
  • [33] High-throughput magnetic resonance imaging
    Golding, SJ
    ACADEMIC RADIOLOGY, 1996, 3 : S53 - S53
  • [34] High resolution magnetic resonance imaging of retinoblastoma
    Schueler, AO
    Hosten, N
    Bechrakis, NE
    Lemke, AJ
    Foerster, P
    Felix, R
    Foerster, MH
    Bornfeld, N
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (03) : 330 - 335
  • [35] High-Field Magnetic Resonance Imaging
    Kangarlu, Alayar
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2009, 19 (01) : 113 - +
  • [36] High resolution and microscopic magnetic resonance imaging
    Cho, Z.H.
    Biomedical Engineering - Applications, Basis and Communications, 1994, 6 (05): : 654 - 659
  • [37] SQUID-detected magnetic resonance imaging in microtesla fields
    Clarke, John
    Hatridge, Michael
    Moessle, Michael
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2007, 9 : 389 - 413
  • [38] Magnetic resonance imaging with stepped B0 fields
    Lee, KJ
    Paley, MN
    Wilkinson, ID
    Griffiths, PD
    MAGNETIC RESONANCE IMAGING, 2003, 21 (06) : 625 - 629
  • [39] Effects of magnetic resonance imaging fields on upper eyelid implants
    Schrom, T
    Bauknecht, H
    Berghaus, A
    Scherer, H
    HNO, 2005, 53 (08) : 741 - 746
  • [40] Cross-encoded magnetic resonance imaging in inhomogeneous fields
    Paquin, Raphael
    Pelupessy, Philippe
    Bodenhausen, Geoffrey
    JOURNAL OF MAGNETIC RESONANCE, 2009, 201 (02) : 199 - 204