Performance optimization of a two-stage parallel thermoelectric cooler with inhomogeneous electrical conductivity

被引:18
|
作者
Huang, Yuewu [1 ]
Chen, Zhuo [1 ]
Ding, Hui [1 ]
机构
[1] Donghua Univ, Coll Environm Sci & Engn, Shanghai 201620, Peoples R China
关键词
Inhomogeneous electrical conductivity; Thermoelectric cooler; Cooling capacity; Coefficient of performance; Thermocouples configuration; EXERGY ANALYSIS; HEAT; REFRIGERATOR; DESIGN; POWER;
D O I
10.1016/j.applthermaleng.2021.116696
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new concept of inhomogeneous thermoelectric materials is advanced recently. In the present study, a novel two-stage thermoelectric cooler (TEC) in electrically parallel configuration is investigated. It is made of the inhomogeneous materials with space-dependent electrical conductivity. The internal irreversibilities of the thermoelectric cooler are taken into account. The temperature profile and heat flux in the thermoelectric legs are derived. Thermal rectification can be realized through the modification of the constant properties model which can result in higher cooling capacity and coefficient of performance (COP). The optimal operating regions are explored. Furthermore, the ratio of thermocouples between two stages, the area-length ratio of legs and cold side temperature have significant effect on some important performance characteristics. In the case of optimal ratio of thermocouples between two stages and optimal area-length ratio of legs, coefficient of performance and cooling capacity rise 22.6% and 28.9% respectively by using inhomogeneous materials.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Design of heat sink for improving the performance of thermoelectric generator using two-stage optimization
    Wang, Chien-Chang
    Hung, Chen-I
    Chen, Wei-Hsin
    ENERGY, 2012, 39 (01) : 236 - 245
  • [22] Analysis of performance and optimum configuration of two-stage semiconductor thermoelectric module
    李开振
    梁瑞生
    魏正军
    Chinese Physics B, 2008, 17 (04) : 1349 - 1354
  • [23] Enhancement of maximum temperature drop across thermoelectric cooler through two-stage design and transient supercooling effect
    Lv, Hao
    Wang, Xiao-Dong
    Meng, Jing-Hui
    Wang, Tian-Hu
    Yan, Wei-Mon
    APPLIED ENERGY, 2016, 175 : 285 - 292
  • [24] Thermodynamic modelling and performance optimization of trapezoidal thermoelectric cooler using genetic algorithm
    Lamba, Ravita
    Manikandan, S.
    Kaushik, S. C.
    Tyagi, S. K.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 6 : 236 - 250
  • [25] RETRACTED: A novel configuration and performance for a two-stage thermoelectric heat pump system driven by a two-stage thermoelectric generator (Retracted Article)
    Chen, L.
    Meng, F.
    Sun, F.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2009, 223 (A4) : 329 - 339
  • [26] Optimization of electrically separated two-stage thermoelectric refrigeration systems using chemical reaction optimization algorithm
    Hadidi, Amin
    APPLIED THERMAL ENGINEERING, 2017, 123 : 514 - 526
  • [27] The influence of Thomson effect in the performance optimization of a two stage thermoelectric generator
    Manikandan, S.
    Kaushik, S. C.
    ENERGY, 2016, 100 : 227 - 237
  • [28] A two-stage sodium converter coupled to a two-stage TEG: Parametric optimization
    Peng, Wanli
    Gonzalez-Ayala, Julian
    Guo, Juncheng
    Dong, Jucan
    Qin, Qi
    APPLIED THERMAL ENGINEERING, 2023, 229
  • [29] Multi-objective optimization of two stage thermoelectric cooler using a modified teaching-learning-based optimization algorithm
    Rao, R. Venkata
    Patel, Vivek
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2013, 26 (01) : 430 - 445
  • [30] Maximum Efficient Power Performance Analysis and Multi-Objective Optimization of Two-Stage Thermoelectric Generators
    Tian, Lei
    Chen, Lingen
    Ge, Yanlin
    Shi, Shuangshuang
    ENTROPY, 2022, 24 (10)