Influence of phantom diameter, kVp and scan mode upon computed tomography dose index

被引:88
|
作者
Nickoloff, EL [1 ]
Dutta, AK [1 ]
Lu, ZF [1 ]
机构
[1] Columbia Univ, Dept Radiol, New York, NY 10962 USA
关键词
D O I
10.1118/1.1543149
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The computed tomography (CT) radiation dose to pediatric patients has received considerable attention recently. Moreover, it is important to be able to determine CT radiation doses for various patient sizes ranging from infants to large adults. The current AAPM protocol only measures CT radiation dose using a 16 cm acrylic phantom to represent an adult head and a 32 cm acrylic phantom to represent an adult body. The goal of this paper is to study the dependence of the computed tomography dose index (CTDI) upon the size of the phantom, the kVp selected and the scan mode employed. Our measurements were done on phantom sizes ranging from 6 cm to 32 cm. The x-ray tube potential ranged from 80 to 140 kVp. The scan modes utilized for the measurements included: consecutive axial scans, single-slice helical scans with variable pitch and multislice helical scans with variable pitch. The results were consolidated into simplified equations which related the phantom diameter and kVp to the measured CTDI. Some generalizations were made about the relationship between the scan modes of the various CT units to the measured radiation doses. The CTDI appears to be an exponential function of phantom diameter. For the same kVp and mAs, the radiation doses for smaller phantoms are much greater than for larger sizes. The derived relationship can be used to estimate the radiation doses for a variety of scan conditions and modes from measurements with the two standard reference phantoms. A method was also given for converting axial CT dose measurements to appropriate MSAD values for helical CT scans. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:395 / 402
页数:8
相关论文
共 50 条
  • [1] Influence of phantom diameter, KVp and scan mode upon CT radiation doses
    Nickoloff, E
    Dutta, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1345 - 1345
  • [2] Influence of the Phantom Length in Computed Tomography Dose Profile Dosimetry
    Takei, Y.
    Suzuki, S.
    Koshida, K.
    Kataoka, Y.
    Kobayashi, M.
    Ootsuka, T.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [3] Clinical effectiveness of computed tomography dose index, multiple scan average dose and dose free in air on the axis of rotation for patients in computed tomography
    Hidajat, N
    Wolf, M
    Schroeder, RJ
    Felix, R
    RADIOLOGY, 1997, 205 : 1400 - 1400
  • [4] Performance assessment of a new dynamic scan mode for perfusion computed tomography using a biological phantom
    Haberland, U.
    Klotz, E.
    Abolmaali, N.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [5] Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study
    Iranmakani, Sepideh
    Jahanshahi, Amir Reza
    Mehnati, Parinaz
    Mortezazadeh, Tohid
    Khezerloo, Davood
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2022, 12 (01): : 64 - 68
  • [6] Dental and Maxillofacial Cone Beam Computed Tomography Dose Index in Full-Fan and Full-Scan Mode
    Jia, S.
    Zhang, L.
    Xing, Y.
    Gao, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E524 - E525
  • [7] Upgrading a Computed Tomography Dose Index (CTDI) Phantom to an Electron Density (ED) Phantom for Commissioning a CT Simulator
    Elaziz, Rehab A.
    Azzam, Alia A.
    Awad, Ibrahim A.
    Osama, Mohamed
    Oraby, Ahmed H.
    Iranian Journal of Medical Physics, 2024, 21 (03) : 154 - 159
  • [8] Calculation of Phantom Volume for Computed Tomography (CT) Scan Images
    Adi, Kusworo
    Widodo, Catur Edi
    Sugiharto, Aris
    Maulana, Qidir B. S.
    Pamungkas, Adi
    2016 3RD INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY, COMPUTER, AND ELECTRICAL ENGINEERING (ICITACEE), 2016, : 220 - 222
  • [9] Simulation of Computed Tomography Dose based on Voxel Phantom
    Liu, Chunyu
    Lv, Xiangbo
    Li, Zhaojun
    SEVENTH INTERNATIONAL CONFERENCE ON ELECTRONICS AND INFORMATION ENGINEERING, 2017, 10322
  • [10] Identification of the computed tomography dose index for tube voltage variations in a polyester-resin phantom
    Fatichah, Lintang N.
    Anam, Choirul
    Sutanto, Heri
    Naufal, Ariij
    Rukmana, Dito A.
    Dougherty, Geoff
    APPLIED RADIATION AND ISOTOPES, 2023, 192