A comparison between the use of a redox mediator in solution and of surface modified electrodes in the electrocatalytic oxidation of nicotinamide adenine dinucleotide

被引:20
作者
Antiochia, R [1 ]
Lavagnini, I [1 ]
Pastore, P [1 ]
Magno, F [1 ]
机构
[1] Univ Padua, Dipartimento Chim Inorgan Met & Anal, I-35131 Padua, Italy
关键词
NADH oxidation; cyclic voltammetry; p-methylamino-phenolsulphate; 3,4-dihydroxybenzaldehyde; modified electrode; carbon nanotube paste electrode;
D O I
10.1016/j.bioelechem.2004.01.002
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Cyclic voltammetry was successfully applied to study the oxidation of nicotinamide adenine dinucleotide (NADH) both in homogeneous and heterogeneous phase. The first case was realized with a solution containing p-methylamino-phenolsulphate (MAP) as redox mediator and the diaphorase (DI) from Clostridium kluveri as enzyme while the second one by using both a glassy carbon (GC) and a carbon nanotube paste (CNTP) electrode modified with electrodeposited films derived from 3,4-dihydroxybenzaldehyde (3,4-DHB). Such systems were successively coupled with glucose dehydrogenase (GDH) reaction to realize the redox chain present in glucose biosensors. A critical comparison of the two systems was also reported. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 37 条
[1]  
ANDRIEUX CP, 1978, J ELECTROANAL CHEM, V93, P163, DOI 10.1016/S0022-0728(78)80230-7
[2]   The interference of oxygen on diaphorase from Clostridium kluveri in the mediated electrocatalytic oxidation of reduced dihydronicotinamide adenine dinucleotide [J].
Antiochia, R ;
Lavagnini, I ;
Magno, F .
ELECTROANALYSIS, 2003, 15 (21) :1713-1718
[3]  
Antiochia R, 1999, ELECTROANAL, V11, P129, DOI 10.1002/(SICI)1521-4109(199902)11:2<129::AID-ELAN129>3.0.CO
[4]  
2-S
[5]  
Antiochia R, 2001, ELECTROANAL, V13, P582, DOI 10.1002/1521-4109(200105)13:7<582::AID-ELAN582>3.0.CO
[6]  
2-M
[7]   Purification and sensor applications of an oxygen insensitive, thermophilic diaphorase [J].
Antiochia, R ;
Cass, AEG ;
Palleschi, G .
ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) :17-28
[8]  
ANTIOCHIA R, 2004, IN PRESS ELECTROANAL
[9]   Modified electrodes for NADH oxidation and dehydrogenase-based biosensors [J].
Bartlett, PN ;
Simon, E ;
Toh, CS .
BIOELECTROCHEMISTRY, 2002, 56 (1-2) :117-122
[10]   CHEMICALLY MODIFIED ELECTRODES FOR THE ELECTROCATALYTIC OXIDATION OF NICOTINAMIDE COENZYMES [J].
GORTON, L .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1245-1258