Relationship between left atrium catheter contact force and pacing threshold

被引:7
作者
Barrio-Lopez, Teresa [1 ,2 ,3 ]
Ortiz, Mercedes [1 ,2 ]
Castellanos, Eduardo [1 ,2 ]
Lazaro, Carla [1 ,2 ]
Salas, Jefferson [1 ,2 ]
Madero, Sergio [1 ,2 ]
Almendral, Jesus [1 ,2 ]
机构
[1] Univ CEU San Pablo, Grp HM Hosp, Hosp Monteprincipe, Electrophysiol Lab, Madrid, Spain
[2] Univ CEU San Pablo, Grp HM Hosp, Hosp Monteprincipe, Arrhythmia Unit, Madrid, Spain
[3] Hosp Madrid Monteprincipe, Unidad Electrofisiol, Avda Monteprincipe 25, Madrid 28660, Spain
关键词
Contact force; Pacing threshold; Left atrium; Ablation; ELECTRODE-TISSUE CONTACT; PULMONARY VEIN ISOLATION; RADIOFREQUENCY ABLATION; POOR PREDICTORS; CANINE HEART; LESION SIZE; STEAM POP; IMPEDANCE; FIBRILLATION; AMPLITUDE;
D O I
10.1007/s10840-017-0253-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study is to analyze the relationship between contact force (CF) and pacing threshold in left atrium (LA). Six to ten LA sites were studied in 28 consecutive patients with atrial fibrillation undergoing pulmonary vein isolation. Median CF, bipolar and unipolar electrogram voltage, impedance, and bipolar and unipolar thresholds for consistent constant capture and for consistent intermittent capture were measured at each site. Pacing threshold measurements were performed at 188 LA sites. Both unipolar and bipolar pacing thresholds correlated significantly with median CF; however, unipolar pacing threshold correlated better (unipolar: Pearson R -0.45; p < 0.001; Spearman Rho -0.62; p < 0.001, bipolar: Pearson R -0.39; p < 0.001; Spearman Rho -0.52; p < 0.001). Consistent constant capture threshold had better correlation with median CF than consistent intermittent capture threshold for both unipolar and bipolar pacing (Pearson R -0.45; p < 0.001 and Spearman Rho -0.62; p < 0.001 vs. Pearson R -0.35; p < 0.001; Spearman Rho -0.52; p < 0.001). The best pacing threshold cutoff point to detect a good CF (> 10 g) was 3.25 mA for unipolar pacing with 69% specificity and 73% sensitivity. Both increased to 80% specificity and 74% sensitivity for sites with normal bipolar voltage and a pacing threshold cutoff value of 2.85 mA. Pacing thresholds correlate with CF in human not previously ablated LA. Since the combination of a normal bipolar voltage and a unipolar pacing threshold < 2.85 mA provide reasonable parameters of validity, pacing threshold could be of interest as a surrogate for CF in LA.
引用
收藏
页码:147 / 155
页数:9
相关论文
共 23 条
[1]   The effects of electrode-tissue contact on radiofrequency lesion generation [J].
Avitall, B ;
Mughal, K ;
Hare, J ;
Helms, R ;
Krum, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (12) :2899-2910
[2]   Ablation Effect Indicated by Impedance Fall is Correlated with Contact Force Level During Ablation for Atrial Fibrillation [J].
De Bortoli, Alessandro ;
Sun, Li-Zhi ;
Solheim, Eivind ;
Hoff, Per Ivar ;
Schuster, Peter ;
Ohm, Ole-Jorgen ;
Chen, Jian .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (11) :1210-1215
[3]   Relationship Between Catheter Forces, Lesion Characteristics, "Popping," and Char Formation: Experience with Robotic Navigation System [J].
Di Biase, Luigi ;
Natale, Andrea ;
Barrett, Conor ;
Tan, Carmela ;
Elayi, Claude S. ;
Ching, Chi Keong ;
Wang, Paul ;
Al-Ahmad, Amin ;
Arruda, Mauricio ;
Burkhardt, J. David ;
Wisnoskey, Brian J. ;
Chowdhury, Punam ;
De Marco, Shari ;
Armaganijan, Luciana ;
Litwak, Kenneth N. ;
Schweikert, Robert A. ;
Cummings, Jennifer E. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (04) :436-440
[4]   The LETR-Principle: A novel method to assess electrode-tissue contact in radiofrequency ablation [J].
Eick, OJ ;
Wittkampf, FH ;
Bronneberg, T ;
Schumacher, B .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (11) :1180-1185
[5]   Circumferential pulmonary vein isolation and linear left atrial ablation as a single-catheter technique to achieve bidirectional conduction block: The pace-and-ablate approach [J].
Eitel, Charlotte ;
Hindricks, Gerhard ;
Sommer, Philipp ;
Gaspar, Thomas ;
Kircher, Simon ;
Wetzel, Ulrike ;
Dagres, Nicos ;
Esato, Masahiro ;
Bollmann, Andreas ;
Husser, Daniela ;
Hilbert, Sebastian ;
Zaker-Shahrak, Ruzbeh ;
Arya, Arash ;
Piorkowski, Christopher .
HEART RHYTHM, 2010, 7 (02) :157-164
[6]   Relationship Between Catheter Contact Force and Radiofrequency Lesion Size and Incidence of Steam Pop in the Beating Canine Heart Electrogram Amplitude, Impedance, and Electrode Temperature Are Poor Predictors of Electrode-Tissue Contact Force and Lesion Size [J].
Ikeda, Atsushi ;
Nakagawa, Hiroshi ;
Lambert, Hendrik ;
Shah, Dipen C. ;
Fonck, Edouard ;
Yulzari, Aude ;
Sharma, Tushar ;
Pitha, Jan V. ;
Lazzara, Ralph ;
Jackman, Warren M. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (06) :1174-1180
[7]  
Kay N, 2011, CLIN CARDIAC PACING, P40
[8]   Effects of electrode-myocardial separation on cardiac stimulation in conductive solution [J].
Knisley, SB ;
Pollard, AE ;
Fast, VG .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (10) :1132-1143
[9]   Predictive value of impedance changes for real-time contact force measurements during catheter ablation of atrial arrhythmias in humans [J].
Kumar, Saurabh ;
Haqqani, H. M. ;
Chan, Martin ;
Lee, Justin ;
Yudi, Matias ;
Wong, Michael C. G. ;
Morton, Joseph B. ;
Ling, Liang-Han ;
Robinson, Timothy ;
Heck, Patrick M. ;
Kelland, Nicholas F. ;
Halloran, Karen ;
Spence, Steven J. ;
Kistler, Peter M. ;
Kalman, Jonathan M. .
HEART RHYTHM, 2013, 10 (07) :962-969
[10]   In Vivo Contact Force Analysis and Correlation With Tissue Impedance During Left Atrial Mapping and Catheter Ablation of Atrial Fibrillation [J].
Makimoto, Hisaki ;
Lin, Tina ;
Rillig, Andreas ;
Metzner, Andreas ;
Wohlmuth, Peter ;
Arya, Anita ;
Antz, Matthias ;
Mathew, Shibu ;
Deiss, Sebastian ;
Wissner, Erik ;
Rausch, Peter ;
Bardyszewski, Aleksander ;
Kamioka, Masashi ;
Li, Xuping ;
Kuck, Karl-Heinz ;
Ouyang, Feifan ;
Tilz, Roland Richard .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (01) :46-54