Performance of six types of oxygen delivery devices at varying respiratory rates

被引:104
作者
Wagstaff, T. A. J. [1 ]
Soni, N. [1 ]
机构
[1] Chelsea & Westminster Hosp, Magill Dept Anaesthesia Intens Care & Pain Manage, London SW10 9NH, England
关键词
D O I
10.1111/j.1365-2044.2007.05026.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The administration of a known concentration of oxygen is an important part of routine care of the sick patient. Many devices are currently available. The actual concentration of oxygen that can be delivered by these devices can be affected by several factors, both from the patient as well as the device itself. Measuring the F(i)o(2) delivered to the lungs in vivo can be both difficult and potentially uncomfortable for the subjects. We constructed a model using a resuscitation manikin, a ventilator and a set of bellows to simulate ventilation. With this model we tested a series of devices - variable performance, fixed performance and high flow - at two fixed tidal volumes. The respiratory rate was increased and its effect on the oxygen concentration assessed. Variable performance systems such as the Hudson mask deliver a significantly reduced oxygen concentration at high respiratory rates. Fixed performance systems delivering 24-40% oxygen deliver appropriate oxygen concentrations across the range of respiratory rates, whereas those delivering 60% show a reduction in performance. High flow systems show no failure of performance at increased respiratory rates.
引用
收藏
页码:492 / 503
页数:12
相关论文
共 23 条
  • [1] INSPIRED OXYGEN AND NITROUS-OXIDE CONCENTRATIONS IN VOLUNTEERS DURING NITROUS-OXIDE SEDATION WITH A HUDSON MASK
    ANDERSON, BJ
    DYSON, A
    HENDERSON, AM
    [J]. ANAESTHESIA AND INTENSIVE CARE, 1988, 16 (04) : 423 - 426
  • [2] VARIABILITY OF INSPIRED OXYGEN CONCENTRATION WITH NASAL CANNULAS
    BAZUAYE, EA
    STONE, TN
    CORRIS, PA
    GIBSON, GJ
    [J]. THORAX, 1992, 47 (08) : 609 - 611
  • [3] 100% inspired oxygen from a Hudson mask - a realistic goal?
    Boumphrey, SM
    Morris, EAJ
    Kinsella, SM
    [J]. RESUSCITATION, 2003, 57 (01) : 69 - 72
  • [4] Hyperthermic, supersaturated humidification in the treatment of xerostomia
    Criswell, MA
    Sinha, CK
    [J]. LARYNGOSCOPE, 2001, 111 (06) : 992 - 996
  • [5] Dinesen Timothy, 2003, Respir Care, V48, P120
  • [6] Nasopharyngeal oxygen in adult intensive care - Lower flows and increased comfort
    Eastwood, GM
    Reeves, JH
    Cowie, BS
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2004, 32 (05) : 670 - 671
  • [7] OXYGEN DELIVERY SYSTEMS - A COMPARISON OF 2 DEVICES
    FAIRFIELD, JE
    GOROSZENIUK, T
    TULLY, AM
    ADAMS, AP
    [J]. ANAESTHESIA, 1991, 46 (02) : 135 - 138
  • [8] PERFORMANCE OF VENTURI OXYGEN DELIVERY DEVICES
    FRACCHIA, G
    TORDA, TA
    [J]. ANAESTHESIA AND INTENSIVE CARE, 1980, 8 (04) : 426 - 430
  • [9] The OxyArM™:: A supplemental oxygen delivery device
    Futrell, JW
    Moore, JL
    [J]. ANESTHESIA AND ANALGESIA, 2006, 102 (02) : 491 - 494
  • [10] Numerical simulation of the flow and concentration fields for oxygen delivery systems
    Hangan, H
    Bekele, S
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (05): : 648 - 662