Advances in MRI Around Metal

被引:168
作者
Jungmann, Pia M. [1 ,2 ,3 ]
Agten, Christoph A. [1 ,2 ]
Pfirrmann, Christian W. [1 ,3 ]
Sutter, Reto [1 ,3 ]
机构
[1] Balgrist Univ Hosp, Dept Radiol, Forchstr 340, CH-8008 Zurich, Switzerland
[2] Univ Zurich, Fac Med, Zurich, Switzerland
[3] Tech Univ Munich, Dept Radiol, Munich, Germany
关键词
orthopedics; metal implants; joint replacement; magnetic resonance imaging; artifacts; postoperative complications; TOTAL HIP-ARTHROPLASTY; TOTAL KNEE ARTHROPLASTY; ARTIFACT REDUCTION TECHNIQUES; RESONANCE-IMAGING ARTIFACT; LEAST-SQUARES ESTIMATION; LOCAL TISSUE-REACTIONS; SPIN-ECHO SEQUENCES; MAGNETIC-RESONANCE; SUSCEPTIBILITY ARTIFACTS; COMPUTED-TOMOGRAPHY;
D O I
10.1002/jmri.25708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The prevalence of orthopedic metal implants is continuously rising in the aging society. Particularly the number of joint replacements is increasing. Although satisfying long-term results are encountered, patients may suffer from complaints or complications during follow-up, and often undergo magnetic resonance imaging (MRI). Yet metal implants cause severe artifacts on MRI, resulting in signal-loss, signal-pileup, geometric distortion, and failure of fat suppression. In order to allow for adequate treatment decisions, metal artifact reduction sequences (MARS) are essential for proper radiological evaluation of postoperative findings in these patients. During recent years, developments of musculoskeletal imaging have addressed this particular technical challenge of postoperative MRI around metal. Besides implant material composition, configuration and location, selection of appropriate MRI hardware, sequences, and parameters influence artifact genesis and reduction. Application of dedicated metal artifact reduction techniques including high bandwidth optimization, view angle tilting (VAT), and the multispectral imaging techniques multiacquisition variable-resonance image combination (MAVRIC) and slice-encoding for metal artifact correction (SEMAC) may significantly reduce metal-induced artifacts, although at the expense of signal-to-noise ratio and/or acquisition time. Adding advanced image acquisition techniques such as parallel imaging, partial Fourier transformation, and advanced reconstruction techniques such as compressed sensing further improves MARS imaging in a clinically feasible scan time. This review focuses on current clinically applicable MARS techniques. Understanding of the main principles and techniques including their limitations allows a considerate application of these techniques in clinical practice. Essential orthopedic metal implants and postoperative MR findings around metal are presented and highlighted with clinical examples.
引用
收藏
页码:972 / 991
页数:20
相关论文
共 165 条
[111]   Treatment of fracture sequelae of the proximal humerus: anatomical vs reverse shoulder prosthesis [J].
Mansat, Pierre ;
Bonnevialle, Nicolas .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (02) :349-354
[112]   Phantom based qualitative and quantitative evaluation of artifacts in MR images of metallic hip prostheses [J].
Mansson, Sven ;
Muller, Gunilla M. ;
Wellman, Fredrik ;
Nittka, Mathias ;
Lundin, Bjorn .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (02) :173-178
[113]   Optimized Imaging of the Postoperative Spine [J].
McLellan, Anne Marie ;
Daniel, Simon ;
Corcuera-Solano, Idoia ;
Joshi, Vivek ;
Tanenbaum, Lawrence N. .
NEUROIMAGING CLINICS OF NORTH AMERICA, 2014, 24 (02) :349-+
[114]   MR imaging with metal artifact-reducing sequences and gadolinium contrast agent in a case-control study of periprosthetic abnormalities in patients with metal-on-metal hip prostheses [J].
Mueller, Gunilla M. ;
Mansson, Sven ;
Mueller, Markus F. ;
von Schewelov, Thord ;
Nittka, Mathias ;
Ekberg, Olle ;
Lundin, Bjorn .
SKELETAL RADIOLOGY, 2014, 43 (08) :1101-1112
[115]   Postsurgical Spinal Magnetic Resonance Imaging With Iterative Decomposition of Water and Fat With Echo Asymmetry and Least-Squares Estimation [J].
Murakami, Mizuho ;
Mori, Harushi ;
Kunimatsu, Akira ;
Abe, Osamu ;
Chikuda, Hirotaka ;
Ono, Takashi ;
Kabasawa, Hiroyuki ;
Uchiumi, Kazuyuki ;
Sato, Jiro ;
Amemiya, Shiori ;
Komatsu, Shuhei ;
Ohtomo, Kuni .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (01) :16-20
[116]   Magnetic resonance imaging of joint replacements [J].
Naraghi, AM ;
White, LM .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2006, 10 (01) :98-106
[117]   Metal artifact suppression at the hip: diagnostic performance at 3.0 T versus 1.5 Tesla [J].
Nardo, Lorenzo ;
Han, Misung ;
Kretschmar, Martin ;
Guindani, Michele ;
Koch, Kevin ;
Vail, Thomas ;
Krug, Roland ;
Link, Thomas M. .
SKELETAL RADIOLOGY, 2015, 44 (11) :1609-1616
[118]  
Nwawka O Kenechi, 2014, HSS J, V10, P213, DOI 10.1007/s11420-014-9399-3
[119]   Optimized protocols for cardiac magnetic resonance imaging in patients with thoracic metallic implants [J].
Olivieri, Laura J. ;
Cross, Russell R. ;
O'Brien, Kendall E. ;
Ratnayaka, Kanishka ;
Hansen, Michael S. .
PEDIATRIC RADIOLOGY, 2015, 45 (10) :1455-1464
[120]  
Otazo Ricardo., 2016, Magnetic Resonance in Medicine