Advances in MRI Around Metal

被引:168
作者
Jungmann, Pia M. [1 ,2 ,3 ]
Agten, Christoph A. [1 ,2 ]
Pfirrmann, Christian W. [1 ,3 ]
Sutter, Reto [1 ,3 ]
机构
[1] Balgrist Univ Hosp, Dept Radiol, Forchstr 340, CH-8008 Zurich, Switzerland
[2] Univ Zurich, Fac Med, Zurich, Switzerland
[3] Tech Univ Munich, Dept Radiol, Munich, Germany
关键词
orthopedics; metal implants; joint replacement; magnetic resonance imaging; artifacts; postoperative complications; TOTAL HIP-ARTHROPLASTY; TOTAL KNEE ARTHROPLASTY; ARTIFACT REDUCTION TECHNIQUES; RESONANCE-IMAGING ARTIFACT; LEAST-SQUARES ESTIMATION; LOCAL TISSUE-REACTIONS; SPIN-ECHO SEQUENCES; MAGNETIC-RESONANCE; SUSCEPTIBILITY ARTIFACTS; COMPUTED-TOMOGRAPHY;
D O I
10.1002/jmri.25708
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The prevalence of orthopedic metal implants is continuously rising in the aging society. Particularly the number of joint replacements is increasing. Although satisfying long-term results are encountered, patients may suffer from complaints or complications during follow-up, and often undergo magnetic resonance imaging (MRI). Yet metal implants cause severe artifacts on MRI, resulting in signal-loss, signal-pileup, geometric distortion, and failure of fat suppression. In order to allow for adequate treatment decisions, metal artifact reduction sequences (MARS) are essential for proper radiological evaluation of postoperative findings in these patients. During recent years, developments of musculoskeletal imaging have addressed this particular technical challenge of postoperative MRI around metal. Besides implant material composition, configuration and location, selection of appropriate MRI hardware, sequences, and parameters influence artifact genesis and reduction. Application of dedicated metal artifact reduction techniques including high bandwidth optimization, view angle tilting (VAT), and the multispectral imaging techniques multiacquisition variable-resonance image combination (MAVRIC) and slice-encoding for metal artifact correction (SEMAC) may significantly reduce metal-induced artifacts, although at the expense of signal-to-noise ratio and/or acquisition time. Adding advanced image acquisition techniques such as parallel imaging, partial Fourier transformation, and advanced reconstruction techniques such as compressed sensing further improves MARS imaging in a clinically feasible scan time. This review focuses on current clinically applicable MARS techniques. Understanding of the main principles and techniques including their limitations allows a considerate application of these techniques in clinical practice. Essential orthopedic metal implants and postoperative MR findings around metal are presented and highlighted with clinical examples.
引用
收藏
页码:972 / 991
页数:20
相关论文
共 165 条
[1]  
Agten CA, 2016, EUR RADIOL
[2]   Unicompartmental knee arthroplasty MRI: impact of slice-encoding for metal artefact correction MRI on image quality, findings and therapy decision [J].
Agten, Christoph A. ;
Del Grande, Filippo ;
Fucentese, Sandro F. ;
Blatter, Samuel ;
Pfirrmann, Christian W. A. ;
Sutter, Reto .
EUROPEAN RADIOLOGY, 2015, 25 (07) :2184-2193
[3]   Postoperative magnetic resonance imaging artifact with cobalt-chromium versus titanium spinal instrumentation [J].
Ahmad, Faiz U. ;
Sidani, Charif ;
Fourzali, Roberto ;
Wang, Michael Y. .
JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (05) :629-636
[4]   SEMAC-VAT and MSVAT-SPACE Sequence Strategies for Metal Artifact Reduction in 1.5T Magnetic Resonance Imaging [J].
Ai, Tao ;
Padua, Abraham ;
Goerner, Frank ;
Nittka, Mathias ;
Gugala, Zbigniew ;
Jadhav, Siddharth ;
Trelles, Miguel ;
Johnson, Raleigh F. ;
Lindsey, Ronald W. ;
Li, Xiaoming ;
Runge, Val M. .
INVESTIGATIVE RADIOLOGY, 2012, 47 (05) :267-276
[5]  
Allison Jerry, 2015, AJR Am J Roentgenol, V205, pW140, DOI 10.2214/AJR.14.14173
[6]   Advances in Metal Artifact Reduction Techniques for Periprosthetic Soft Tissue Imaging [J].
Ariyanayagam, Timothy ;
Malcolm, Paul Napier ;
Toms, Andoni Paul .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (04) :328-334
[7]   Knee implant imaging at 3 Tesla using high-bandwidth radiofrequency pulses [J].
Bachschmidt, Theresa J. ;
Sutter, Reto ;
Jakob, Peter M. ;
Pfirrmann, Christian W. A. ;
Nittka, Mathias .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (06) :1570-1580
[8]   SUSCEPTIBILITY ARTIFACTS IN 2DFT SPIN-ECHO AND GRADIENT-ECHO IMAGING - THE CYLINDER MODEL REVISITED [J].
BAKKER, CJG ;
BHAGWANDIEN, R ;
MOERLAND, MA ;
FUDERER, M .
MAGNETIC RESONANCE IMAGING, 1993, 11 (04) :539-548
[9]   Magnetic resonance imaging artefacts and fixed orthodontic attachments [J].
Beau, Aurelien ;
Bossard, Denis ;
Gebeile-Chauty, Sarah .
EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (01) :105-110
[10]   Postoperative MRI of the Shoulder [J].
Beltran, Luis S. ;
Bencardino, Jenny T. ;
Steinbach, Lynne S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (06) :1280-1297