Procedural Guidance Using Advance Imaging Techniques for Percutaneous Edge-to-Edge Mitral Valve Repair

被引:19
作者
Quaife, Robert A. [1 ]
Salcedo, Ernesto E. [1 ]
Carroll, John D. [1 ]
机构
[1] Univ Colorado Denver, Div Cardiol, Aurora, CO 80045 USA
关键词
Guidance; Structural heart disease; Mitral clip procedure; 3dimensional; Trans-esophageal echocardiogram; Percutaneous edge-to-edge mitral valve repair; Imaging techniques; 3-DIMENSIONAL ECHOCARDIOGRAPHY; TEE;
D O I
10.1007/s11886-013-0452-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The complexity of structural heart disease interventions such as edge-to edge mitral valve repair requires integration of multiple highly technical imaging modalities. Real time imaging with 3-dimensional (3D) echocardiography is a relatively new technique that first, allows clear volumetric imaging of target structures such as the mitral valve for both pre-procedural diagnosis and planning in patients with degenerative or functional mitral valve regurgitation. Secondly it provides intra-procedural, real-time panoramic volumetric 3D view of structural heart disease targets that facilitates eye-hand coordination while manipulating devices within the heart. Xray fluoroscopy and RT 3D TEE images are used in combination to display specific targets and movement of catheter based technologies in 3D space. This integration requires at least two different image display monitors and mentally fusing the individual datasets by the operator. Combined display technology such as this, allow rotation and orientation of both dataset perspectives necessary to define targets and guidance of structural disease device procedures. The inherently easy concept of direct visual feedback and eye-hand coordination allows safe and efficient completion of MitraClip procedures. This technology is now merged into a single structural heart disease guidance mode called EchoNavigator (TM) (Philips Medical Imaging Andover, MA). These advanced imaging techniques have revolutionized the field of structural heart disease interventions and this experience is exemplified by a cooperative imaging approach used for guidance of edge-to-edge mitral valve repair procedures.
引用
收藏
页数:9
相关论文
共 22 条
[1]  
Amin Z, 2004, CIRCULATION, V110, P566
[2]  
[Anonymous], 2006, AM J CARDIOL, V98, p1M
[3]   Utility of Combined Two-Dimensional and Three-Dimensional Transesophageal Imaging for Catheter-Based Mitral Valve Clip Repair of Mitral Regurgitation [J].
Biner, Simon ;
Perk, Gila ;
Kar, Saibal ;
Rafique, Asim M. ;
Slater, James ;
Shiota, Takahiro ;
Hussaini, Asma ;
Chou, Stanley ;
Kronzon, Itzhak ;
Siegel, Robert J. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (06) :611-617
[4]   INTEGRATED 3D ECHO-X-RAY IMAGE GUIDANCE FOR STRUCTURAL HEART INTERVENTIONS [J].
Clegg, Stacey D. ;
Chen, James ;
Salcedo, Ernesto ;
Quaife, Robert ;
Carroll, John .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) :E326-E326
[5]  
Eng MJ, 2013, CATHETER CARDIOVASC, DOI [10.1002/ccd.2505219, DOI 10.1002/CCD.2505219]
[6]   Side-by-Side Comparison of Fluoroscopy, 2D and 3D TEE During Percutaneous Edge-to-Edge Mitral Valve Repair [J].
Faletra, Francesco F. ;
Pedrazzini, Giovanni ;
Pasotti, Elena ;
Moccetti, Tiziano .
JACC-CARDIOVASCULAR IMAGING, 2012, 5 (06) :656-661
[7]   Percutaneous mitral valve repair using the edge-to-edge technique: Six-month results of the EVEREST phase I clinical trial [J].
Feldman, T ;
Wasserman, HS ;
Herrmann, HC ;
Gray, W ;
Block, PC ;
Whitlow, P ;
Goar, FS ;
Rodriguez, L ;
Silvestry, F ;
Schwartz, A ;
Sanborn, TA ;
Condado, JA ;
Foster, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (11) :2134-2140
[8]   Intraprocedure guidance for percutaneous mitral valve interventions: TTE, TEE, ICE, or X-ray? [J].
Feldman, T .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (03) :395-396
[9]   Interventional three-dimensional echocardiography: Using real-time three-dimensional echocardiography to guide and evaluate intracardiac therapies [J].
Gill, Edward A. ;
Liang, David H. .
CARDIOLOGY CLINICS, 2007, 25 (02) :335-+
[10]   Three-dimensional echocardiography: Historical development and current applications [J].
Lange, A ;
Palka, P ;
Burstow, DJ ;
Godman, MJ .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (05) :403-412