Development and validation of a low dose simulator for computed tomography

被引:32
作者
Joemai, R. M. S. [1 ,2 ]
Geleijns, J. [2 ]
Veldkamp, W. J. H. [2 ]
机构
[1] Leiden Univ, Dept Radiol, Med Ctr, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Dept Radiol, Med Ctr, NL-2333 ZA Leiden, Netherlands
关键词
Computed tomography; X-ray; Radiation; Physics; Computer simulation; Noise; IMAGE QUALITY; CT; REDUCTION; COLONOGRAPHY; FEASIBILITY;
D O I
10.1007/s00330-009-1617-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To develop and validate software for facilitating observer studies on the effect of radiation exposure on the diagnostic value of computed tomography (CT). A low dose simulator was developed which adds noise to the raw CT data. For validation two phantoms were used: a cylindrical test object and an anthropomorphic phantom. Images of both were acquired at different dose levels by changing the tube current of the acquisition (500 mA to 20 mA in five steps). Additionally, low dose simulations were performed from 500 mA downwards to 20 mA in the same steps. Noise was measured within the cylindrical test object and in the anthropomorphic phantom. Finally, noise power spectra (NPS) were measured in water. The low dose simulator yielded similar image quality compared with actual low dose acquisitions. Mean difference in noise over all comparisons between actual and simulated images was 5.7 +/- 4.6% for the cylindrical test object and 3.3 +/- 2.6% for the anthropomorphic phantom. NPS measurements showed that the general shape and intensity are similar. The developed low dose simulator creates images that accurately represent the image quality of acquisitions at lower dose levels and is suitable for application in clinical studies.
引用
收藏
页码:958 / 966
页数:9
相关论文
共 12 条
  • [1] [Anonymous], 2009, National Council on Radiation Protection and Measurement report No. 160: Ionizing radiation exposure of the population of the United States
  • [2] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284
  • [3] Addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: an example application to X-ray CT of the brain
    Britten, AJ
    Crotty, M
    Kiremidjian, H
    Grundy, A
    Adam, EJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (916) : 323 - 328
  • [4] Appendicitis in children: Low-dose CT with a phantom-based simulation technique-initial observations
    Fefferman, NR
    Bomsztyk, E
    Yim, AM
    Rivera, R
    Amodio, JB
    Pinkney, LP
    Strubel, NA
    Noz, ME
    Rusinek, H
    [J]. RADIOLOGY, 2005, 237 (02) : 641 - 646
  • [5] Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study
    Florie, Jasper
    van Gelder, Rogier E.
    Schutter, Michiel P.
    van Randen, Adrienne
    Venema, Henk W.
    de Jager, Steven
    van der Hulst, Victor P. M.
    Prent, Anna
    Bipat, Shandra
    Bossuyt, Patrick M. M.
    Baak, Lubbertus C.
    Stoker, Jaap
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (12) : 3112 - 3122
  • [6] Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients
    Frush, DP
    Slack, CC
    Hollingsworth, CL
    Bisset, GS
    Donnelly, LF
    Hsieh, J
    Lavin-Wensell, T
    Mayo, JR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) : 1107 - 1113
  • [7] Computer-simulation technique for low dose computed tomographic screening
    Hanai, Kouzou
    Horiuchi, Tetsuya
    Sekiguchi, Junko
    Muramatsu, Yoshihisa
    Kakinuma, Ryutaro
    Moriyama, Noriyuki
    Tuchiiya, Ryosuke
    Niki, Noboru
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (06) : 955 - 961
  • [8] Validation of CT dose-reduction simulation
    Massoumzadeh, Parinaz
    Don, Steven
    Hildebolt, Charles F.
    Bae, Kyongtae T.
    Whiting, Bruce R.
    [J]. MEDICAL PHYSICS, 2009, 36 (01) : 174 - 189
  • [9] Simulated dose reduction in conventional chest CT: Validation study
    Mayo, JR
    Whittall, KP
    Leung, AN
    Hartman, TE
    Park, CS
    Primack, SL
    Chambers, GK
    Limkeman, MK
    Toth, TL
    Fox, SH
    [J]. RADIOLOGY, 1997, 202 (02) : 453 - 457
  • [10] Multi-detector row CT pulmonary angiography: Comparison of standard-dose and simulated low-dose techniques
    Tack, D
    De Maertelaer, V
    Petit, W
    Scillia, P
    Muller, P
    Suess, C
    Gevenois, PA
    [J]. RADIOLOGY, 2005, 236 (01) : 318 - 325