Evaluation of the eazyplex MRSA assay for the rapid detection of Staphylococcus aureus in pleural and synovial fluid

被引:10
|
作者
Henares, D. [1 ]
Brotons, P. [1 ,2 ]
Buyse, X. [1 ]
Latorre, I. [1 ,3 ,4 ]
de Paz, H. D. [1 ]
Munoz-Almagro, C. [1 ,2 ,5 ]
机构
[1] Hosp St Joan de Deu, Dept Microbiol Mol, Inst Recerca Pediat, Barcelona, Spain
[2] CIBER Epidemiol & Salud Publ CIBERESP, Barcelona, Spain
[3] Inst Invest Germans Trias & Pujol, Badalona, Spain
[4] CIBER Enfermedades Resp CIBERES, Barcelona, Spain
[5] Univ Int Catalunya, Sch Med, Barcelona, Spain
关键词
MSSA; MRSA; Pleural and synovial fluid; eazyplex MRSA; Performance evaluation; MEDIATED ISOTHERMAL AMPLIFICATION; METHICILLIN-RESISTANT; GENE;
D O I
10.1016/j.ijid.2017.04.013
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objective: Loop-mediated isothermal amplification (LAMP) is a simple and sensitive technique for rapid microbiological diagnosis. The aim of this study was to evaluate the analytical and diagnostic performance of the LAMP eazyplex MRSA test for the direct detection and differentiation of methicillin-susceptible (MSSA) and methicillin-resistant Staphylococcus aureus (MRSA) in synovial/pleural fluid. Methods: Analytical validation included the determination of the limit of detection (LoD) and analytical specificity of the eazyplex MRSA test. A diagnostic evaluation of the eazyplex test against bacterial culture was performed on routine pleural/synovial samples collected prospectively from patients aged less than 18 years with complicated pneumonia with empyema or arthritis admitted to the Children's Hospital Sant Joan de Deu in Barcelona, Spain, between April 2015 and May 2016. Results: The new system appropriately detected a quality control panel of clinical samples with DNA of MSSA, MRSA, and other pathogens. The LoD was established at 6.4 x 10(3) CFU/ml for S. aureus and 1.0 x 10(4) CFU/ml for MRSA. Diagnostic validation of the eazyplex MRSA assay was performed on 51 prospective clinical invasive samples, resulting in sensitivity and specificity values of 83.3% and 97.8%, respectively, for S. aureus detection. The mean turnaround time was 70 min. Conclusions: The eazyplex MRSA assay was found to be a useful test for the rapid detection of S. aureus in invasive samples such as pleural/synovial fluid. (C) 2017 The Authors. Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 50 条
  • [1] Evaluation of the TPX MRSA assay for the detection of methicillin-resistant Staphylococcus aureus
    Stenholm, T.
    Hakanen, A. J.
    Salmenlinna, S.
    Pihlasalo, S.
    Harma, H.
    Hanninen, P. E.
    Huovinen, P.
    Vuopio, J.
    Kotilainen, P.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2011, 30 (10) : 1237 - 1243
  • [2] Evaluation of a rapid assay for detection of PBP2a Staphylococcus aureus
    Sainz-Rodriguez, Rocio
    de Toro-Peinado, Inmaculada
    Valverde-Troya, Miriam
    Bermudez Ruiz, Ma Pilar
    Palop-Borras, Begona
    REVISTA ESPANOLA DE QUIMIOTERAPIA, 2019, 32 (04) : 370 - 374
  • [3] Evaluation of the MRSA/SA ELITe MGB Assay for the Detection of Staphylococcus aureus in Bone and Joint Infections
    Labetoulle, R.
    Rigaill, J.
    Lleres-Vadeboin, M.
    Grattard, F.
    Pozzetto, B.
    Cazorla, C.
    Botelho-Nevers, E.
    Boyer, B.
    Dupieux-Chabert, C.
    Laurent, F.
    Verhoeven, P. O.
    Carricajo, A.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2022, 60 (01)
  • [4] Evaluation of an immunochromatographic assay for detection of PBP2a on non-Staphylococcus aureus clinical isolates
    Mantion, Benoit
    Cavalie, Laurent
    Prere, Marie-Francoise
    JOURNAL OF MICROBIOLOGICAL METHODS, 2015, 112 : 46 - 48
  • [5] Evaluation of colorimetric nitrate reductase assay for rapid detection of methicillin resistance in clinical isolates of Staphylococcus aureus
    Niveditha, N.
    Sistla, Sujatha
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2016, 143 : 87 - 91
  • [6] Evaluation of a novel optical assay for rapid detection of methicillin-resistant Staphylococcus aureus in liquid culture
    Knaack, Dennis
    Idelevich, Evgeny A.
    Koerber-Ingang, Barbara
    Kresken, Michael
    Becker, Karsten
    JOURNAL OF MICROBIOLOGICAL METHODS, 2018, 146 : 68 - 70
  • [7] Clinical utility of the Xpert MRSA assay for early detection of methicillin-resistant Staphylococcus aureus
    OH, Ae-Chin
    Lee, Jin Kyung
    Lee, Ha Na
    Hong, Young Jun
    Chang, Yoon Hwan
    Hong, Seok-Il
    Kim, Dong Ho
    MOLECULAR MEDICINE REPORTS, 2013, 7 (01) : 11 - 15
  • [8] Development of fluorescence-linked immunosorbent assay for rapid detection of Staphylococcus aureus
    Kim, Joo-Kyung
    Yun, Hyun-Young
    Kim, Jae-Seok
    Kim, Wooseong
    Lee, Chang-Soo
    Kim, Byung-Gee
    Jeong, Hee-Jin
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2024, 108 (01) : 1 - 10
  • [9] Loop-Mediated Isothermal Amplification Assay for the Rapid Detection of Staphylococcus aureus
    Lim, King Ting
    Teh, Cindy Shuan Ju
    Thong, Kwai Lin
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [10] GenomEra MRSA/SA, a fully automated homogeneous PCR assay for rapid detection of Staphylococcus aureus and the marker of methicillin resistance in various sample matrixes
    Hirvonen, Jari J.
    Kaukoranta, Suvi-Sirkku
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2013, 13 (07) : 655 - 665