Coupled complex adjoint sensitivities for frequency-domain fluorescence tomography: theory and vectorized implementation

被引:56
作者
Fedele, F
Laible, JP
Eppstein, MJ [1 ]
机构
[1] Univ Vermont, Dept Comp Sci, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Civil & Environm Engn, Burlington, VT 05405 USA
关键词
adjoint sensitivities; vectorization; fluorescence tomography; coupled elliptic equations;
D O I
10.1016/S0021-9991(03)00150-5
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a computationally efficient and accurate adjoint method for calculating coupled sensitivities of complex frequency-domain excitation and emission fluence to any underlying optical parameters in highly scattering media. The method is shown to be general and accurate. Novel vectorized implementations for finite element global matrix assembly and adjoint sensitivity calculations are shown to speed up calculations by orders of magnitude over traditional loop implementations, thereby making least-squares approaches to fluorescence tomography computationally practical. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:597 / 619
页数:23
相关论文
共 42 条
  • [1] Synthesis, in vitro receptor binding, and in vivo evaluation of fluorescein and carbocyanine peptide-based optical contrast agents
    Achilefu, S
    Jimenez, HN
    Dorshow, RB
    Bugaj, JE
    Webb, EG
    Wilhelm, RR
    Rajagopalan, R
    Johler, J
    Erion, JL
    [J]. JOURNAL OF MEDICINAL CHEMISTRY, 2002, 45 (10) : 2003 - 2015
  • [2] [Anonymous], 1995, ADJOINT EQUATIONS AN, DOI DOI 10.1007/978-94-017-0621-6
  • [3] PHOTON-MEASUREMENT DENSITY-FUNCTIONS .1. ANALYTICAL FORMS
    ARRIDGE, SR
    [J]. APPLIED OPTICS, 1995, 34 (31): : 7395 - 7409
  • [4] PHOTON-MEASUREMENT DENSITY-FUNCTIONS .2. FINITE-ELEMENT-METHOD CALCULATIONS
    ARRIDGE, SR
    SCHWEIGER, M
    [J]. APPLIED OPTICS, 1995, 34 (34): : 8026 - 8037
  • [5] Optical tomography in medical imaging
    Arridge, SR
    [J]. INVERSE PROBLEMS, 1999, 15 (02) : R41 - R93
  • [6] Receptor-targeted optical imaging of tumors with near-infrared fluorescent ligands
    Becker, A
    Hessenius, C
    Licha, K
    Ebert, B
    Sukowski, U
    Semmler, W
    Wiedenmann, B
    Grötzinger, C
    [J]. NATURE BIOTECHNOLOGY, 2001, 19 (04) : 327 - 331
  • [7] Improved reconstruction algorithm for luminescence optical tomography when background lumiphore is present
    Chang, J
    Graber, HL
    Barbour, RL
    [J]. APPLIED OPTICS, 1998, 37 (16): : 3547 - 3552
  • [8] Chang JW, 1995, P SOC PHOTO-OPT INS, V2570, P59, DOI 10.1117/12.224186
  • [9] CHENOMORDIK V, 1999, IEEE J SEL TOP QUANT, V54, P930
  • [10] Biomedical optical tomography using dynamic parameterization and Bayesian conditioning on photon migration measurements
    Eppstein, MJ
    Dougherty, DE
    Troy, TL
    Sevick-Muraca, EM
    [J]. APPLIED OPTICS, 1999, 38 (10) : 2138 - 2150