Analysis of High-Frequency Resonance in DFIG-Based Offshore Wind Farm via Long Transmission Cable

被引:56
作者
Song, Yipeng [1 ]
Ebrahimzadeh, Esmaeil [1 ]
Blaabjerg, Frede [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
DFIG system; wind farm; II unit model based long transmission cable; high frequency resonance; transformer leakage inductance; SSR ANALYSIS; TURBINES;
D O I
10.1109/TEC.2018.2794367
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
During the past two decades, the doubly fed induction generator (DFIG) based wind farm has been under rapid growth, and the increasing wind power penetration has been seen. Practically, these wind farms are connected to the three-phase ac grid through long transmission cable which can be modeled as several II units. The impedance of this cable cannot he neglected and requires careful investigation due to its long distance. As a result, the impedance interaction between the DFIG-based wind farm and the long cable is inevitable, and may produce high-frequency resonance (HFR) in the wind farm. This paper discusses the HFR of the large-scale DFIG-based wind farm connected to the long cable. Several influencing factors, including 1) the length of the cable, 2) the output active power, and 3) the rotor speed, are investigated. The transformer leakage inductances in the transmission system are taken into consideration when investigating the HFR. Simulation validations using MATLAB/Simulink have been conducted to verify the theoretical analysis.
引用
收藏
页码:1036 / 1046
页数:11
相关论文
共 23 条
[1]  
[Anonymous], 2014, P CONTR MOD POW EL
[2]   Future on Power Electronics for Wind Turbine Systems [J].
Blaabjerg, Frede ;
Ma, Ke .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2013, 1 (03) :139-152
[3]   Harmonic resonance characteristics of large-scale distributed power plant in wideband frequency domain [J].
Chen, Zhiyong ;
Luo, An ;
Kuang, Huimin ;
Zhou, Leming ;
Chen, Yandong ;
Huang, Yuan .
ELECTRIC POWER SYSTEMS RESEARCH, 2017, 143 :53-65
[4]   Mitigating SSR Using DFIG-Based Wind Generation [J].
Fan, Lingling ;
Miao, Zhixin .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2012, 3 (03) :349-358
[5]   Nyquist-Stability-Criterion-Based SSR Explanation for Type-3 Wind Generators [J].
Fan, Lingling ;
Miao, Zhixin .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (03) :807-809
[6]   Modeling of Type 3 Wind Turbines With df/dt Inertia Control for System Frequency Response Study [J].
Hu, Jiabing ;
Sun, Li ;
Yuan, Xiaoming ;
Wang, Shuo ;
Chi, Yongning .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (04) :2799-2809
[7]   Small Signal Dynamics of DFIG-Based Wind Turbines During Riding Through Symmetrical Faults in Weak AC Grid [J].
Hu, Jiabing ;
Wang, Bo ;
Wang, Weisheng ;
Tang, Haiyan ;
Chi, Yongning ;
Hu, Qi .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2017, 32 (02) :720-730
[8]   Power Electronic Drives, Controls, and Electric Generators for Large Wind Turbines-An Overview [J].
Ma, Ke ;
Tutelea, Lucian ;
Boldea, Ion ;
Ionel, Dan M. ;
Blaabjerg, Frede .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (12) :1406-1421
[9]   Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network [J].
Miao, Zhixin .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (04) :984-991
[10]   Direct Resonant Control Strategy for Torque Ripple Mitigation of DFIG Connected to DC Link through Diode Rectifier on Stator [J].
Nian, Heng ;
Wu, Chao ;
Cheng, Peng .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (09) :6936-6945