Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: A prospective computed tomography-controlled study

被引:64
作者
Fink, C
Benedetto, KP
Hackl, W
Hoser, C
Freund, MC
Rieger, M
机构
[1] Univ Innsbruck, Hosp Traumatol, A-6020 Innsbruck, Austria
[2] Univ Innsbruck Hosp, Dept Radiol 1, A-6020 Innsbruck, Austria
关键词
ACL reconstruction; bioabsorbable interference screw; polyglyconate;
D O I
10.1053/jars.2000.4633
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: It was the purpose of the study to evaluate a new polyglyconate bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction. Type of Study: Prospective randomized. Materials and Methods: Ferry patients who underwent endoscopic ACL reconstruction were included in the study and randomized intraoperatively. Group A consisted of 20 patients (6 women, 14 men; mean age, 29.6 years) who had femoral bone block fixation with a bioabsorbable interference screw and tibial fixation with a titanium interference screw. Group B included 20 patients (5 women, 15 men; mean age 29.6 years) who had fixation of both femoral and tibial bone blocks with titanium interference screws. There was no significant difference between the groups with regard to age, Sender, height, weight, time from injury to surgery, activity level, and concomitant injuries. Results: Clinical results (using IKDC, Lysholm, Tegner scores) of the 2 groups as well as instrumented laxity measurements (KT-1000) did not show significant (P > .05) differences at any stage of follow-up. No complications with respect to graft fixation could be found. Computed tomography scans, performed within the first postoperative week, at 6 weeks, and at 3, 6, 12, and 24 months postoperatively revealed a uniform picture for all patients within the groups, showing completed screw degradation at 12 months in group A. Conclusion: Polyglyconate interference screw fixation for patellar tendon grafts has not been found to be associated with increased clinical complications or significant osteolysis. It provided equivalent fixation and clinical results compared with titanium screws. However, replacement of the screw with bone did not take place for up to 3 years postoperatively.
引用
收藏
页码:491 / 498
页数:8
相关论文
共 38 条
  • [1] ARTHROSCOPIC BIOABSORBABLE TACK STABILIZATION OF INITIAL ANTERIOR SHOULDER DISLOCATIONS - A PRELIMINARY-REPORT
    ARCIERO, RA
    TAYLOR, DC
    SNYDER, RJ
    UHORCHAK, JM
    [J]. ARTHROSCOPY, 1995, 11 (04): : 410 - 417
  • [2] PRELIMINARY-RESULTS OF AN ABSORBABLE INTERFERENCE SCREW
    BARBER, FA
    ELROD, BF
    MCGUIRE, DA
    PAULOS, LE
    [J]. ARTHROSCOPY, 1995, 11 (05): : 537 - 548
  • [3] BARFOD G, 1992, ACTA ORTHOP SCAND, V63, P680
  • [4] DEGRADATION AND TISSUE REPLACEMENT OF AN ABSORBABLE POLYGLYCOLIDE SCREW IN THE FIXATION OF RABBIT FEMORAL OSTEOTOMIES
    BOSTMAN, O
    PAIVARINTA, U
    PARTIO, E
    VASENIUS, J
    MANNINEN, M
    ROKKANEN, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) : 1021 - 1031
  • [5] FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS
    BOSTMAN, O
    HIRVENSALO, E
    MAKINEN, J
    ROKKANEN, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04): : 592 - 596
  • [6] Comparison of ''inside-out'' and ''outside-in'' interference screw fixation for anterior cruciate ligament surgery in a bovine knee
    Bryan, JM
    Bach, BR
    BushJoesph, CA
    Fisher, IM
    Hsu, KY
    [J]. ARTHROSCOPY, 1996, 12 (01): : 76 - 81
  • [7] CARLIER R, 1998, 8 C EUR SOC SPORTS T, P220
  • [8] INSTRUMENTED MEASUREMENT OF ANTERIOR LAXITY OF THE KNEE
    DANIEL, DM
    MALCOM, LL
    LOSSE, G
    STONE, ML
    SACHS, R
    BURKS, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (05) : 720 - 726
  • [9] Edwards D J, 1994, J Shoulder Elbow Surg, V3, P230, DOI 10.1016/S1058-2746(09)80040-2
  • [10] SEVERE ASEPTIC SYNOVITIS OF THE KNEE AFTER BIODEGRADABLE INTERNAL-FIXATION - A CASE-REPORT
    FRIDEN, T
    RYDHOLM, U
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01): : 94 - 97