Distance to isocenter is not associated with an increased risk for local failure in LINAC-based single-isocenter SRS or SRT for multiple brain metastases

被引:32
作者
Kraft, Johannes [1 ,2 ]
van Timmeren, Janita E. [1 ]
Mayinger, Michael [1 ]
Frei, Simon [1 ]
Borsky, Kim [1 ]
Stark, Luisa Sabrina [1 ]
Krayenbuehl, Jerome [1 ]
Zamburlini, Mariangela [1 ]
Guckenberger, Matthias [1 ]
Tanadini-Lang, Stephanie [1 ]
Andratschke, Nicolaus [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[2] Univ Hosp Wuerzburg, Dept Radiat Oncol, Wurzburg, Germany
关键词
Brain metastases; Radiosurgery; Stereotactic radiotherapy; Single isocenter multiple targets technique; VMAT; MODULATED STEREOTACTIC RADIOSURGERY; ROTATIONAL SETUP ERRORS; ARC RADIOSURGERY; TARGET VOLUME; FRAMELESS; MANAGEMENT; THERAPY; RADIOTHERAPY; PREDICTOR; ACCURACY;
D O I
10.1016/j.radonc.2021.03.022
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the impact of the distance between treatment isocenter and brain metastases on local failure in patients treated with a frameless linear-accelerator-based single-isocenter volumetric modulated arc (VMAT) SRS/SRT for multiple brain metastases. Methods and materials: Patients treated with SRT for brain metastases (BM) between April 2014 and May 2019 were included in this retrospective study. BM treated with a single-isocenter multiple-target (SIMT) SRT were evaluated for local recurrence-free intervals in dependency to their distance to the treatment isocenter. A Cox-regression model was used to investigate different predictor variables for local failure. Results were compared to patients treated with a single-isocenter-single-target (SIST) approach. Results: In total 315 patients with a cumulative number of 1087 BM were analyzed in this study of which 140 patients and 708 BM were treated with SIMT SRS/SRT. Median follow-up after treatment was 13.9 months for SIMT approach and 11.9 months for SIST approach. One-year freedom from local recurrence was 87% and 94% in the SIST and SIMT group, respectively. Median distance to isocenter (DTI) was 4.7 cm (range 0.2-10.5) in the SIMT group. Local recurrence-free interval was not associated with the distance to the isocenter in univariable or multivariable Cox-regression analysis. Multivariable analysis revealed only volume as an independent significant predictor for local failure (p-value <0.05). Conclusion: SRS/SRT using single-isocenter VMAT for multiple targets achieved high local metastases control rates irrespective of distance to the isocenter, supporting efficacy of single-isocenter stereotactic radiation therapy for multiple brain metastases. (c) 2021 Elsevier B.V. All rights reserved. Radiotherapy and Oncology 159 (2021) 168-175
引用
收藏
页码:168 / 175
页数:8
相关论文
共 50 条
[21]   Radiosurgery of multiple brain metastases with single-isocenter dynamic conformal arcs (SIDCA) [J].
Huang, Yimei ;
Chin, Karen ;
Robbins, Jared R. ;
Kim, Jinkoo ;
Li, Haisen ;
Amro, Hanan ;
Chetty, Indrin J. ;
Gordon, James ;
Ryu, Samuel .
RADIOTHERAPY AND ONCOLOGY, 2014, 112 (01) :128-132
[22]   Single-Isocenter Volumetric Modulated Arc Therapy (VMAT) Radiosurgery for Multiple Brain Metastases: Potential Loss of Target(s) Coverage Due to Isocenter Misalignment [J].
Palmiero, Allison N. ;
Critchfield, Lana ;
St Clair, William ;
Randall, Marcus ;
Pokhrel, Damodar .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (10)
[23]   SINGLE-ISOCENTER FRAMELESS INTENSITY-MODULATED STEREOTACTIC RADIOSURGERY FOR SIMULTANEOUS TREATMENT OF MULTIPLE BRAIN METASTASES: CLINICAL EXPERIENCE [J].
Nath, Sameer K. ;
Lawson, Joshua D. ;
Simpson, Daniel R. ;
VanderSpek, Lauren ;
Wang, Jia-Zhu ;
Alksne, John F. ;
Ciacci, Joseph ;
Mundt, Arno J. ;
Murphy, Kevin T. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01) :91-97
[24]   Optimization of isocenter position for multiple brain metastases single-isocenter stereotactic radiosurgery to minimize dosimetric variations due to rotational uncertainty [J].
Shen, Zhenjiong ;
wang, Hao ;
Shao, Yan ;
Duan, Yanhua ;
Gu, Hengle ;
Chen, Hua ;
Feng, Aihui ;
Huang, Ying ;
Xu, Zhiyong .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 111
[25]   Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems [J].
Raza, Giorgio Hamid ;
Capone, Luca ;
Tini, Paolo ;
Giraffa, Martina ;
Gentile, Piercarlo ;
Minniti, Giuseppe .
RADIATION ONCOLOGY, 2022, 17 (01)
[26]   Impact of MLC error on dose distribution in SRS treatment of single-isocenter multiple brain metastases: comparison between DCAT and VMAT techniques [J].
Katayama, Hiroki ;
Kobata, Takuya ;
Kitaoka, Motonori ;
Takahashi, Shigeo ;
Shibata, Toru .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2024, 29 (05) :531-543
[27]   Linac-based VMAT radiosurgery for multiple brain lesions: comparison between a conventional multi-isocenter approach and a new dedicated mono-isocenter technique [J].
Ruggero Ruggieri ;
Stefania Naccarato ;
Rosario Mazzola ;
Francesco Ricchetti ;
Stefanie Corradini ;
Alba Fiorentino ;
Filippo Alongi .
Radiation Oncology, 13
[28]   On a single isocenter volumetric modulated arc therapy SRS planning technique for multiple brain metastases [J].
Hardcastle, Nicholas ;
Tome, Wolfgang A. .
JOURNAL OF RADIOSURGERY AND SBRT, 2012, 2 (01) :1-9
[29]   Multicomponent mathematical model for tumor volume calculation with setup error using single-isocenter stereotactic radiotherapy for multiple brain metastases [J].
Nakano, Hisashi ;
Shiinoki, Takehiro ;
Tanabe, Satoshi ;
Nakano, Toshimichi ;
Takizawa, Takeshi ;
Utsunomiya, Satoru ;
Sakai, Madoka ;
Tanabe, Shunpei ;
Ohta, Atsushi ;
Kaidu, Motoki ;
Nishio, Teiji ;
Ishikawa, Hiroyuki .
PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (02) :945-953
[30]   Stereotactic radiosurgery for multiple small brain metastases using gamma knife versus single-isocenter VMAT: Normal brain dose based on lesion number and size [J].
Abdou, Abram ;
Almeida, Timoteo ;
Bossart, Elizabeth ;
Monterroso, Irene ;
Mellon, Eric A. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (06)