Remotely adjustable check-valves with an electrochemical release mechanism for implantable biomedical microsystems

被引:7
作者
Pan, Tingrui
Baldi, Antonio
Ziaie, Babak [1 ]
机构
[1] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[3] CSIC, CNM, IMB, Ctr Nacl Microelect, Madrid, Spain
基金
美国国家科学基金会;
关键词
microfluidic; microvalve; wireless implantable microsystem; gold dissolution; glaucoma;
D O I
10.1007/s10544-006-9043-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we present two remotely adjustable check-valves with an electrochemical release mechanism for implantable biomedical microsystems. These valves allow one to vary the opening pressure set-point and flow resistance over a period of time. The first design consists of a micromachined check-valve array using a SU-8 polymer structural layer deposited on the top of a gold sacrificial layer. The second design is based on a variable length cantilever beam structure with a gold sacrificial layer. The adjustable cantilever-beam structure is fabricated by gold thermo-compression bond of a thin silicon wafer over a glass substrate. In both designs, the evaporated gold can be electrochemically dissolved using a constant DC current via a telemetry link. In the first design the dissolution simply opens up individual outlets, while in the second design, gold anchors are sequentially dissolved hence increasing the effective length of the cantilever beam (reducing the opening pressure). A current density of 35 mA/cm(2) is used to dissolve the gold sacrificial layers. Both gravity and syringe-pump driven flow are used to characterize the valve performance. A multi-stage fluidic performance (e.g. flow resistance and opening pressure) is clearly demonstrated.
引用
收藏
页码:385 / 394
页数:10
相关论文
共 18 条
[1]  
BROWN JD, 1989, OPHTHALMOLOGY, V96, P1468
[2]  
GRETZINGER DT, 1995, P IEEE EMBS, V95, P673
[3]  
GUERIN L, 1997, P IEEE TRANSDUCERS, V97, P1419
[4]  
LABIANCA N, 1995, P SOC PHOTO-OPT INS, V2438, P846, DOI 10.1117/12.210413
[5]   SU-8: a low-cost negative resist for MEMS [J].
Lorenz, H ;
Despont, M ;
Fahrni, N ;
LaBianca, N ;
Renaud, P ;
Vettiger, P .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (03) :121-124
[6]   Mechanical characterization of a new high-aspect-ratio near UV-photoresist [J].
Lorenz, H ;
Laudon, M ;
Renaud, P .
MICROELECTRONIC ENGINEERING, 1998, 42 :371-374
[7]   Microactuators toward microwaves for responsive controlled drug delivery [J].
Low, LM ;
Seetharaman, S ;
He, KQ ;
Madou, MJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (1-2) :149-160
[8]   Modeling and characterization of a valved glaucoma drainage device with implications for enhanced therapeutic efficacy [J].
Pan, T ;
Stay, MS ;
Barocas, VH ;
Brown, JD ;
Ziaie, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (05) :948-951
[9]  
PAN T, 2002, P IEEE EMBS, V2, P1830
[10]  
PAN T, 2003, P IEEE EMBS, V3