A two-stage Stirling-type pulse tube cryocooler with a cold inertance tube

被引:25
作者
Gan, Z. H. [1 ,2 ]
Fan, B. Y. [1 ]
Wu, Y. Z. [1 ]
Qiu, L. M. [1 ,2 ]
Zhang, X. J. [1 ]
Chen, G. B. [1 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen Engn, Cryogen Lab, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
关键词
Pulse tube refrigeration; REGEN3.2; Regenerator; Cold inertance tube; High frequency;
D O I
10.1016/j.cryogenics.2010.03.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
A thermally coupled two-stage Stirling-type pulse tube cryocooler (PTC) with inertance tubes as phase shifters has been designed, manufactured and tested. In order to obtain a larger phase shift at the low acoustic power of about 2.0 W, a cold inertance tube as well as a cold reservoir for the second stage, pre-cooled by the cold end of the first stage, was introduced into the system. The transmission line model was used to calculate the phase shift produced by the cold inertance tube. Effect of regenerator material, geometry and charging pressure on the performance of the second stage of the two-stage PTC was investigated based on the well known regenerator model REGEN. Experimental results of the two-stage PTC were carried out with an emphasis on the performance of the second stage. A lowest cooling temperature of 23.7 K and 0.50 W at 33.9 K were obtained with an input electric power of 150.0 W and an operating frequency of 40 Hz. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:426 / 431
页数:6
相关论文
共 50 条
  • [31] Numerical and experimental study on a 20 K high capacity thermally-coupled Stirling-type pulse tube cooler
    Ding, Xupeng
    Wang, Xiaotao
    Zhang, Yibing
    Huang, Shengli
    Yan, Chao
    Li, Zhengkun
    Dai, Wei
    Li, Haibing
    ENERGY, 2025, 316
  • [32] A single-stage GM-type pulse tube cryocooler operating at 10.6 K
    Gan, Z. H.
    Dong, W. Q.
    Qiu, L. M.
    Zhang, X. B.
    Sun, H.
    He, Y. L.
    Radebaugh, R.
    CRYOGENICS, 2009, 49 (05) : 198 - 201
  • [33] Two stage pulse tube cryocooler with intermediate heat exchanger for accessing regenerator cooling capacity
    Falter, Jens
    Herrmann, Xaver
    Schmidt, Bernd
    Dietzel, Dirk
    Schirmeisen, Andre
    CRYOGENICS, 2024, 144
  • [34] Performance of a precooled 4 K Stirling type high frequency pulse tube cryocooler with Gd2O2S
    Li, Zhuo-pei
    Jiang, Yan-long
    Gan, Zhi-hua
    Qiu, Li-min
    Chen, Jie
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2014, 15 (07): : 508 - 516
  • [35] An adiabatic model for a two-stage double-inlet pulse tube refrigerator
    Shafi, K. A.
    Rasheed, K. K. A.
    George, J. M.
    Sajid, N. K. M.
    Kasthurirengan, S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2008, 222 (07) : 1247 - 1252
  • [36] Intermediate cooling from pulse tube and regenerator in a 4 K pulse tube cryocooler
    Wang, Chao
    CRYOGENICS, 2008, 48 (3-4) : 154 - 159
  • [37] Numerical simulation of a two-stage pulse tube refrigerator based on adiabatic model
    Thejaswini, M. N.
    Chandan, V.
    Kasthurirengan, S.
    Vasudevan, K.
    HEAT TRANSFER-ASIAN RESEARCH, 2018, 47 (05): : 705 - 717
  • [38] STUDY ON A SINGLE-STAGE 120HZ PULSE TUBE CRYOCOOLER
    Wu, Y. Z.
    Gan, Z. H.
    Qiu, L. M.
    Chen, J.
    Li, Z. P.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 175 - 182
  • [39] Modelling of pulse tube refrigerators with inertance tube and mass-spring feedback mechanism
    Wang, Kai
    Dubey, Swapnil
    Choo, Fook Hoong
    Duan, Fei
    APPLIED ENERGY, 2016, 171 : 172 - 183
  • [40] Study on cold head structure of a 300 Hz thermoacoustically driven pulse tube cryocooler
    Yu, G. Y.
    Wang, X. T.
    Dai, W.
    Luo, E. C.
    CRYOGENICS, 2012, 52 (4-6) : 212 - 215