Concentration of tetrachloroethylene in indoor air at a former dry cleaner facility as a function of subsurface contamination: A case study

被引:10
作者
Eklund, Bart M.
Simon, Michelle A.
机构
[1] URS Corp, Austin, TX 78720 USA
[2] US EPA, Cincinnati, OH 45268 USA
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 2007年 / 57卷 / 06期
关键词
D O I
10.3155/1047-3289.57.6.753
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A field study was performed to evaluate indoor air concentrations and vapor intrusion (VI) of tetrachloroethylene (PCE) and other chlorinated solvents at a commercial retail site in Dallas, TX. The building is approximately 40 yr old and once housed a dry cleaning operation. Results from an initial site characterization were used to select sampling locations for the VI study. The general approach for evaluating VI was to collect time-integrated canister samples for off-site U.S. Environmental Protection Agency Method TO-15 analyses. PCE and other chlorinated solvents were measured in shallow soil gas, subslab soil-gas, indoor air, and ambient air. The subslab soil gas exhibited relatively high values: PCE <= 2,600,000 parts per billion by volume (ppbv) and trichloroethylene <= 170 ppbv. The attenuation factor, the ratio of indoor air and subslab soil-gas concentrations, was unusually low: approximately 5 x 10(-6) based on the maximum subslab soil-gas concentration of PCE and 1.4.x 10(-5) based on average values.
引用
收藏
页码:753 / 760
页数:8
相关论文
共 23 条
[1]   Simulating the effect of aerobic biodegradation on soil vapor intrusion into buildings: Influence of degradation rate, source concentration, and depth [J].
Abreu, LDV ;
Johnson, PC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (07) :2304-2315
[2]  
[Anonymous], 1997, EPA600P95002FA
[3]  
[Anonymous], 1999, Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air, V2nd ed.
[4]  
[Anonymous], US TRIAD APPR STREAM
[5]  
BOYER J, 2005, EM FEB, P14
[6]  
Cummings J.B., 1997, P 18 ANN AIVC C, V1, P153
[7]   Chemical vapor intrusion from soil or groundwater to indoor air: Significance of unsaturated zone biodegradation of aromatic hydrocarbons [J].
DeVaull, G ;
Ettinger, R ;
Gustafson, J .
SOIL & SEDIMENT CONTAMINATION, 2002, 11 (04) :625-641
[8]  
EPA, 2003, US GUID EV SUBS VAP
[9]   Factors affecting indoor air concentrations of volatile organic compounds at a site of subsurface gasoline contamination [J].
Fischer, ML ;
Bentley, AJ ;
Dunkin, KA ;
Hodgson, AT ;
Nazaroff, WW ;
Sextro, RG ;
Daisey, JM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (10) :2948-2957
[10]  
Hodgson AT, 2003, LBNL51715