The effective elastic properties of human trabecular bone may be approximated using micro-finite element analyses of embedded volume elements

被引:16
作者
Daszkiewicz, Karol [1 ,2 ]
Maquer, Ghislain [1 ]
Zysset, Philippe K. [1 ]
机构
[1] Univ Bern, Inst Surg Technol & Biomech, Bern, Switzerland
[2] Gdansk Univ Technol, Fac Civil & Environm Engn, Gdansk, Poland
关键词
Trabecular bone; Elastic properties; Boundary conditions; Micro-finite elements; In situ; Embedded configuration; HETEROGENEOUS BODIES SMALLER; REPRESENTATIVE VOLUME; BOUNDARY-CONDITIONS; MORPHOLOGY; ANISOTROPY; STRENGTH; MODELS; MODULUS; COMPOSITES; FRACTION;
D O I
10.1007/s10237-016-0849-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Boundary conditions (BCs) and sample size affect the measured elastic properties of cancellous bone. Samples too small to be representative appear stiffer under kinematic uniform BCs (KUBCs) than under periodicity-compatible mixed uniform BCs (PMUBCs). To avoid those effects, we propose to determine the effective properties of trabecular bone using an embedded configuration. Cubic samples of various sizes (2.63, 5.29, 7.96, 10.58 and 15.87 mm) were cropped from mu CT scans of femoral heads and vertebral bodies. They were converted into mu FE models and their stiffness tensor was established via six uniaxial and shear load cases. PMUBCs- and KUBCs-based tensors were determined for each sample. "In situ" stiffness tensors were also evaluated for the embedded configuration, i.e. when the loads were transmitted to the samples via a layer of trabecular bone. The Zysset-Curnier model accounting for bone volume fraction and fabric anisotropy was fitted to those stiffness tensors, and model parameters nu(0) (Poisson's ratio) E-0 and mu(0) (elastic and shear moduli) were compared between sizes. BCs and sample size had little impact on nu(0). However, KUBCs- and PMUBCs-based E-0 and mu(0), respectively, decreased and increased with growing size, though convergence was not reached even for our largest samples. Both BCs produced upper and lower bounds for the in situ values that were almost constant across samples dimensions, thus appearing as an approximation of the effective properties. PMUBCs seem also appropriate for mimicking the trabecular core, but they still underestimate its elastic properties (especially in shear) even for nearly orthotropic samples.
引用
收藏
页码:731 / 742
页数:12
相关论文
共 43 条
[41]   A global relationship between trabecular bone morphology and homogenized elastic properties [J].
Zysset, PK ;
Goulet, RW ;
Hollister, SJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (05) :640-646
[42]   AN ALTERNATIVE MODEL FOR ANISOTROPIC ELASTICITY BASED ON FABRIC TENSORS [J].
ZYSSET, PK ;
CURNIER, A .
MECHANICS OF MATERIALS, 1995, 21 (04) :243-250
[43]   A review of morphology-elasticity relationships in human trabecular bone: theories and experiments [J].
Zysset, PK .
JOURNAL OF BIOMECHANICS, 2003, 36 (10) :1469-1485