The effective elastic properties of human trabecular bone may be approximated using micro-finite element analyses of embedded volume elements

被引:16
作者
Daszkiewicz, Karol [1 ,2 ]
Maquer, Ghislain [1 ]
Zysset, Philippe K. [1 ]
机构
[1] Univ Bern, Inst Surg Technol & Biomech, Bern, Switzerland
[2] Gdansk Univ Technol, Fac Civil & Environm Engn, Gdansk, Poland
关键词
Trabecular bone; Elastic properties; Boundary conditions; Micro-finite elements; In situ; Embedded configuration; HETEROGENEOUS BODIES SMALLER; REPRESENTATIVE VOLUME; BOUNDARY-CONDITIONS; MORPHOLOGY; ANISOTROPY; STRENGTH; MODELS; MODULUS; COMPOSITES; FRACTION;
D O I
10.1007/s10237-016-0849-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Boundary conditions (BCs) and sample size affect the measured elastic properties of cancellous bone. Samples too small to be representative appear stiffer under kinematic uniform BCs (KUBCs) than under periodicity-compatible mixed uniform BCs (PMUBCs). To avoid those effects, we propose to determine the effective properties of trabecular bone using an embedded configuration. Cubic samples of various sizes (2.63, 5.29, 7.96, 10.58 and 15.87 mm) were cropped from mu CT scans of femoral heads and vertebral bodies. They were converted into mu FE models and their stiffness tensor was established via six uniaxial and shear load cases. PMUBCs- and KUBCs-based tensors were determined for each sample. "In situ" stiffness tensors were also evaluated for the embedded configuration, i.e. when the loads were transmitted to the samples via a layer of trabecular bone. The Zysset-Curnier model accounting for bone volume fraction and fabric anisotropy was fitted to those stiffness tensors, and model parameters nu(0) (Poisson's ratio) E-0 and mu(0) (elastic and shear moduli) were compared between sizes. BCs and sample size had little impact on nu(0). However, KUBCs- and PMUBCs-based E-0 and mu(0), respectively, decreased and increased with growing size, though convergence was not reached even for our largest samples. Both BCs produced upper and lower bounds for the in situ values that were almost constant across samples dimensions, thus appearing as an approximation of the effective properties. PMUBCs seem also appropriate for mimicking the trabecular core, but they still underestimate its elastic properties (especially in shear) even for nearly orthotropic samples.
引用
收藏
页码:731 / 742
页数:12
相关论文
共 43 条
[1]  
[Anonymous], 2012, Microcontinuum field theories: I. Foundations and solidsM
[2]   Side-artifact errors in yield strength and elastic modulus for human trabecular bone and their dependence on bone volume fraction and anatomic site [J].
BeVill, Grant ;
Easley, Sarah K. ;
Keaveny, Tony M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (15) :3381-3388
[3]   RVE procedure for estimating the elastic properties of inhomogeneous microstructures such as bone tissue [J].
Blöß, Tanja ;
Welsch, Michael .
Lecture Notes in Applied and Computational Mechanics, 2015, 74 :1-17
[4]  
Bohm H., 2016, CDL-FMD report 3-1998
[5]   THE ELASTIC-MODULI OF HUMAN SUBCHONDRAL, TRABECULAR, AND CORTICAL BONE TISSUE AND THE SIZE-DEPENDENCY OF CORTICAL BONE MODULUS [J].
CHOI, K ;
KUHN, JL ;
CIARELLI, MJ ;
GOLDSTEIN, SA .
JOURNAL OF BIOMECHANICS, 1990, 23 (11) :1103-1113
[6]  
Flaig C, 2012, THESIS
[7]   Morphology-elasticity relationships using decreasing fabric information of human trabecular bone from three major anatomical locations [J].
Gross, Thomas ;
Pahr, Dieter H. ;
Zysset, Philippe K. .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2013, 12 (04) :793-800
[8]   The Epidemiology of Osteoporosis-Bone Evaluation Study (BEST) An Analysis of Routine Health Insurance Data [J].
Hadji, Peyman ;
Klein, Silvia ;
Gothe, Holger ;
Haeussler, Bertram ;
Kless, Thomas ;
Schmidt, Torsten ;
Steinle, Thomas ;
Verheyen, Frank ;
Linder, Roland .
DEUTSCHES ARZTEBLATT INTERNATIONAL, 2013, 110 (04) :52-U23
[9]   CHARACTERIZATION OF MICROSTRUCTURAL ANISOTROPY IN ORTHOTROPIC MATERIALS USING A 2ND RANK TENSOR [J].
HARRIGAN, TP ;
MANN, RW .
JOURNAL OF MATERIALS SCIENCE, 1984, 19 (03) :761-767
[10]   Comparison of trabecular bone behavior in core and whole bone samples using high-resolution modeling of a vertebral body [J].
Harrison, Noel M. ;
McHugh, Peter E. .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2010, 9 (04) :469-480